• Title/Summary/Keyword: Fire examination

Search Result 138, Processing Time 0.026 seconds

An Theoretical study on Spalling Mechanism of Concrete (콘크리트 폭렬발생 메카니즘에 관한 이론적 고찰)

  • Kim, Hyung-Jun;Kim, Heung-Youl;Kim, Gyeong-Ok
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.422-427
    • /
    • 2008
  • The major cause of Concrete Spalling at high temperatures can be divided into the Vapor Pressure Rising, caused by the increase in free water temperature within the concrete, and Pore Pressure Rising induced by the vapor moving into dense pores within the concrete. Although the occurrence of spalling within concrete caused by these pressure increases can be assessed experimentally, a close examination into Mechanistic influence against various spalling factors shall be carried out first by using Mathematical Modeling and Theoretical Equations. The Spalling Prospect Process by theoretical mechanism is expedited in order of the following; selection of heating condition (fire strength and flame heating direction), a selection of constituent elements, an analysis of heat transmission, an analysis of moisture movement, distribution of water content, an analysis of pore/vapor pressure, and assessment of spalling occurrence.

  • PDF

A Study on the Development of a Lanchester-Type Model Incorporating Firing & Observing States in the Direct Fire Engagement (Firing State와 Observing State를 갖는 Lanchester형 전투모형에 관한 연구)

  • Ham Il-Hwan;Choe Sang-Yeong;Song Mun-Ho
    • Journal of the military operations research society of Korea
    • /
    • v.17 no.2
    • /
    • pp.44-53
    • /
    • 1991
  • This paper is aimed to develop a Lanchester type combat model for the direct-fire engagement. This model incorporates number of combatants, inter-firing time, detection time by movement, detection probability by the signature of fire, where the inter-firing time and the detection time are assumed to follow a negative exponential distribution. The approach to modeling is as follows : in the process of an engagement, a combatant takes one of the states('observing' state or 'firing' state), a combatant is initially in the observing state, if the combatant detects a target, he changes his state from 'observing' to 'firing' and will cause attrition to the opposing forces. Thus this transition mechanism is embodied into the differential equation form with each transition rate. A limited examination of the validity has been conducted by comparison with the Monte-Carlo simulation model 'BAGSIM', and with a traditional Deterministic Lanchester model.

  • PDF

Examination of Ingredients of High Temperature Heat Resistant Inorganic Fire-Resistant Adhesive Using XRD Analysis (XRD 분석을 이용한 고온가열 무기계 내화 접착제의 성분검토)

  • Cho, Hyeon-Seo;Ji, Woo-Ram;Shin, Ki-Don;Lee, Gun-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.81-82
    • /
    • 2018
  • The structure of the RC structure is actively reinforcing the structure of the building which has suffered from aging, artificial and natural damage of the building. Among various reinforcement methods, epoxy adhesive is used to attach FRP in FRP reinforcement method which is reinforcing by attaching FRP to the structural part. At this time, the epoxy adhesive having a low critical temperature has a sudden adhesive failure upon exposure to heat, and thus, the development of an inorganic fireproof adhesive having a high critical temperature has progressed. Therefore, in this study, the compositional change of inorganic fire - resistant adhesive exposed to high temperature heat was analyzed by XRD.

  • PDF

Evaluation on Fire Resistance Performance of High Strength Concrete Containing Fibre (섬유혼입 고강도 콘크리트의 내화성능 평가)

  • Song, Young-Chan;Kim, Yong-Ro;Kim, Ook-Jong;Lee, Do-Bum
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.5
    • /
    • pp.129-135
    • /
    • 2010
  • The purpose of this research is to secure fundamental data on the application of fibre as a fire resistance method for more than 60 MPa high-strength concrete through an examination of mechanical properties and fire resistance performance. The results are as follows: 1) When there are less than 0.5~1.0kg/$m^3$ contents of PP and NY fibre for 60MPa and less high strength concrete, 1.0kg/$m^3$ contents of PP and NY fibre for less than 80MPa high strength concrete and 1.5kg/$m^3$ contents of NY fibre for more than 80MPa high strength concrete, the effect of fibre contents on workability and strength development is not significant. 2) Based on the result of a 3-hour fire resistance test for mock-up column, it is necessary to secure 50 mm of covering depth for the regulation of fire resistance performance of high strength concrete to the standards of The Ministry of Land, Transport and Maritime Affairs. 3) It is necessary to secure more than 400mm of column size for stable fire resistance performance.

Water Jet Experiment of Automatic Fire-tracking Water Cannon Facility combined with Indoor Hydrant Facility in Road Tunnels (도로터널의 옥내소화전설비 겸용 자동화점추적 방수총설비의 방수실험)

  • Kim, Chang-Yong;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.92-98
    • /
    • 2019
  • To determine if water-jet nozzle moves and water jetting are effective according to the location of the fire, this study examined the automatic fire-tracking water cannon system and aan indoor hydrant system, such as water jet centered directivity, water jet range maintainability and water jet shape uniformity. First, an examination to find the center of fire accurately from this system design showed that the water jet centered test was accurate. Second, the water jet range test results showed that when water is jetted at the maximum water jet radius, the water jet shows an inaccurate result but within the allowable tolerance range. Finally, the water-jet shape test result confirmed that there are no problems in setting the block from the algorithm design.

Reduced-scale Model Experiment for Examination of Natural Vent and Fire Curtain Effects in Fire of Theater Stage (공연장 무대부 화재 시 자연배출구 및 방화막 영향 검토를 위한 축소모형 실험)

  • Baek, Seon A;Yang, Ji Hyun;Jeong, Chan Seok;Lee, Chi Young;Kim, Duncan
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.41-49
    • /
    • 2019
  • In the present experimental study, based on a real-scale theater, a 1/14 reduced-scale model was constructed, and the effects of natural vent and fire curtain in fire of a theater stage were investigated. The case without fire curtain under the opened natural vent showed lower temperatures in the stage, whereas the case with fire curtain under the opened natural vent showed lower temperatures in the auditorium. On the other hand, through analyzing the starting time of the temperature rise at the point near the proscenium opening in the auditorium, it was found that the opened natural vent condition can delay the starting time of smoke spread from the stage to the auditorium and suppress the temperature rise in the auditorium. Under the present experimental conditions, the fire curtain installation did not affect significantly the velocity and mass flow rate of the outflow through the natural vent of the stage, which might be due to openings in the stage. The present results can be used to examine the effects of natural vent and fire curtain in a real-scale fire of a theater and to check the accuracy of the numerical simulation code.

Comparison of the Efficacy between Method of Regulating Ascending Kidney Water and Descending Heart Fire and Sweet Bee Venom Pharmacopuncture on Peripheral Facial Paralysis (말초성 안면신경마비에 대한 수화조절법과 SBV약침치료의 효능비교)

  • Lee, Chang-Hwan;Ku, Ji-Young;Park, Jung-Ah;Lee, Yoo-Hwan;Jang, Kyung-Jeon;Song, Choon-Ho;Kim, Cheol-Hong;Youn, Hyoun-Min
    • Journal of Acupuncture Research
    • /
    • v.28 no.4
    • /
    • pp.85-92
    • /
    • 2011
  • Objectives : This study was designed to compare the effect between method of regulating ascending kidney water and descending heart fire and sweet bee venom pharmacopuncture on peripheral facial paralysis. Methods : We investigated 30 cases of patient with peripheral facial paralysis who visited at Dept. of Acupuncture & Moxibustion, of Oriental Medicine Dong-eui University from November 29, 2010 to May 15, 2011. Subjects were divided randomly into two groups, group A and group B. We applied method of regulating ascending kidney water and descending heart fire twice or three times a week for group A and sweet bee venom pharmacopuncture with same cycle for group B. We measured the effect of treatment to each group five times by using Yanagihara's unweighed grading system. at first examination, after 1 week, 2 weeks, 3 weeks, and 4 weeks. Results : Both groups showed significant improvement in Yanagihara's scores. And group A was improved better than group B for two weeks from the first examination significantly. But after one week from then, the Yanagihara's scores of group B were higher than those of group A significantly. There were no significant differences during other period. Conclusions : Method of regulating ascending kidney water and descending heart fire is more effective than sweet bee venom pharmacopuncture on peripheral facial paralysis during acute period. And after acute period, sweet bee venom pharmacopuncture is more effective than method of regulating ascending kidney water and descending heart fire.

ISO 9705 Room-Corner Test & Model simulations (ISO 9705 Room-Corner Test와 모델 평가)

  • ;S.E. Dillom;J,G Quintiere
    • Fire Science and Engineering
    • /
    • v.13 no.2
    • /
    • pp.3-11
    • /
    • 1999
  • New examination of a predictive model for the ISO 9705 room-corner test have been m made for materials studied by L S Fire Laboratories, Italy. The ISO 9705 test subjects wall a and ceiling mounted materials to a comer ignition source of 100 kW for a duration of 10 m minutes; if flashover does not occur this is followed by 300 kW for another 10 minutes. The m materials that did not stay in place during combustion because of melting, dripping, or d distorting were simulated by an adjustment to the material's total available energy. For m mat려als that remain in place the simulation model appears to do well in its prl어ictions. A l large-s떠Ie room test results 뾰 compar벼 with the m여el’s prediction also.

  • PDF

Examination on Numerical Simulation Using Reduced-scale Model of Theater Fire: Influences of Fire Curtain and Stage Natural Vent (공연장 화재 축소모형을 이용한 전산시뮬레이션 검토: 방화막 및 무대부 자연배출구 영향)

  • Yang, Ji Hyun;Baek, Seon A;Lee, Chi Young;Kim, Duncan
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.37-47
    • /
    • 2019
  • In the present study, the influences of the fire curtain and natural vent in a theater fire were investigated through the numerical simulation of a reduced-scale model of a theater fire using the Fire Dynamics Simulator (FDS). Based on a previous experimental study using the reduced-scale model, the 1/14 reduced-scale model and its conditions were constructed according to the law of similarity with a real-scale theater. Through a series of numerical simulations, the smoke movements were visualized, and the temperatures in the stage and auditorium, mass flow rate of the outflow through natural vent, and time at which smoke started moving toward the auditorium were measured and analyzed. The general trends on the effects of the fire curtain and natural vent during the theater fire predicted by the present numerical simulation were similar to the previous experimental results. For quantitative comparison of the present numerical simulation and previous experimental results, the mean percentage errors of temperatures in the stage and auditorium, and the mass flow rate of outflow through the natural vent were calculated. The present numerical simulation results showed good agreement with previous experimental results with reasonable accuracy.

'HWABYUNG' in the view of Oriental Medinine (한의학에서 본 홧병의 해석)

  • Kim Jong-Woo;Whang Wei-Wan
    • Journal of Oriental Neuropsychiatry
    • /
    • v.5 no.1
    • /
    • pp.9-15
    • /
    • 1994
  • Hwabyung is a culture-related disease generally know among people in Korea, and various studies have been done by the Psychiatrists and by the Oriental Medical Doctors. While the Psychiatrists explain the Hwabyung as a disease having a unique patholoical process, the Oriental Medical Doctors explain it as a symptoms having the character of fire. When interpreted in Oriental Medical point of view, this can be concluded as 1)the cause of the disease is the depression of liver-energy(肝氣鬱結) induced by emotional suppression, 2)the reason why the disease occurs mostly to female is that they usually fail overcoming stresses and have physical and visceral weaknesses, 3)the symptoms are associated with the dynamics of fire, because the disease originates from the rising character of fire and from the inadequit supression of extreme heart-fire(心火) by the kidney-wter(腎水), 4)the reason why the disease goes through chronic process is because of the complexed emotions, converted fire caused by prolonged emotional disorder and inapropreate supression of fire with grow older. This results suggest thst the cooperative study of the clinical examination of the Psychiatrsis and the study on the fire by the Oriental Medical Doctors is necessary to establish the process of the disease, the pathological procedure, the prognosis and the method of treatment.

  • PDF