• Title/Summary/Keyword: Fire events

Search Result 154, Processing Time 0.031 seconds

A Study on the Evaluation Method of the Building Safety Performance and the Prediction of Occupants′ Egress Behavior during Building Fires with Computer Simulation (컴퓨터시뮬레이션에 의한 피난행태예측 및 안전성능평가방법에 관한 연구(II))

  • 최원령;이경회
    • Fire Science and Engineering
    • /
    • v.3 no.2
    • /
    • pp.11-19
    • /
    • 1989
  • In this study, the independent variables are the floor plan configulation. The dependent variables are the occupant's egress behavior, especially spatial movement pattern, and life - safety performance of building. Fire events were simulated on single story of office building. Simulation run for allowable secaping thime(180 seconds) arbitrarily selected, and involved 48 occupants. The major findings Pre as follows. 1) Computer simulation model suggested in this study can be used as the Preoccupancy evaluation method of the life-safety performance for architectural design based on prediction of occupants' egress behavior in the levels of validity and sensitivity, 2) Sucess or failure in occupants' escape is determined by decreasing walking speed caused by jamming at exits or over crowded corridor, and increasing route length caused by running about in confusion at each subdivision and corridor. 3) In floor plan configuration which safe areas located at the extreme ends of the corridor, cellular floor planning have to be avoided preventing jamming and running about in confusion at overcrowded corridor.

  • PDF

Systematic Emergency Exit Planning Method in School Design (ㄷ자형 초등학교의 비상구를 중심으로 한 정량적 배치방법)

  • Lee, Seung-Sun;Kwun, Joon-Bum;Jeong, In-Jae
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.18 no.5
    • /
    • pp.35-42
    • /
    • 2011
  • This study examined emergency exit location with the most representing school floor type with a mathematical model that applied optimized algorithm in the field of engineering. Recent school buildings became much more diverse in floor planning than the old days. Nevertheless, architect's approach to building prevention against fire related emergency planning still relies on an personal experience and knowledge. Therefore, since school buildings are much more likely to be exposed to any fire related events, emergency exit planning has to be seriously evaluated with a scientific method. The algorithm, which acquires the number of persons in each spatial type(node) and the minimum physical distance between spatial types(arc), can propose the most optimized emergency exit locations. Consequently, this study compared an architect's fire exit planning with the scientific outcome of this study and suggested the most reliable emergency exit locations.

  • PDF

Study on Dispersion Characteristics for Fire Scenarios in an Urban Area Using a CFD-WRF Coupled Model (CFD-WRF 접합 모델을 이용한 도시 지역 화재 시나리오별 확산 특성 연구)

  • Choi, Hee-Wook;Kim, Do-Yong;Kim, Jae-Jin;Kim, Ki-Young;Woo, Jung-Hun
    • Atmosphere
    • /
    • v.22 no.1
    • /
    • pp.47-55
    • /
    • 2012
  • The characteristics of flow and pollutant dispersion for fire scenarios in an urban area are numerically investigated. A computational fluid dynamics (CFD) model coupled to a mesoscale weather research and forecasting (WRF) model is used in this study. In order to more accurately represent the effect of topography and buildings, the geographic information system (GIS) data is used as an input data of the CFD model. Considering prevailing wind, firing time, and firing points, four fire scenarios are setup in April 2008 when fire events occurred most frequently in recent five years. It is shown that the building configuration mainly determines wind speed and direction in the urban area. The pollutant dispersion patterns are different for each fire scenario, because of the influence of the detailed flow. The pollutant concentration is high in the horse-shoe vortex and recirculation zones (caused by buildings) close to the fire point. It thus means that the potential damage areas are different for each fire scenario due to the different flow and dispersion patterns. These results suggest that the accurate understanding of the urban flow is important to assess the effect of the pollutant dispersion caused by fire in an urban area. The present study also demonstrates that CFD model can be useful for the assessment of urban environment.

Analysis on the Fire Accidents Vehicles Caused by Faults in the Same Anti-lock Brake System (ABS) of the same Manufacturer (동일한 제조사의 ABS 모듈 결함으로 인한 차량화재 사고사례 분석)

  • Park, Nam-Kyu;Lee, Dong-Kyu;Cho, Young-Jin;Moon, Byung-Sun;Song, Jae-Yong
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.121-127
    • /
    • 2019
  • This study examined a fire accident caused by a defect in the vehicle ABS module. A large number of vehicles using the same manufacturer's ABS module in recent fire events showed a tendency to combust due to the same faults. As previously stated in the ABS module which shows the electrical breakdown between the power lines supplied to the constant power source by the battery. The electrical breakdown of the ABS module was caused by defects of the ABS module itself that were influenced by of the external flame. These results highlight the need to determine if there is a deficiency of the ABS module in the investigation of the cause of a fire in a vehicle which is produced by the same manufacturer.

Recoverability analysis of Forest Fire Area Based on Satellite Imagery: Applications to DMZ in the Western Imjin Estuary (위성영상을 이용한 서부임진강하구권역 내 DMZ 산불지역 회복성 분석)

  • Kim, Jang Soo;Oh, Jeong-Sik
    • Journal of The Geomorphological Association of Korea
    • /
    • v.28 no.1
    • /
    • pp.83-99
    • /
    • 2021
  • Burn severity analysis using satellite imagery has high capabilities for research and management in inaccessible areas. We extracted the forest fire area of the DMZ (Demilitarized Zone) in the western Imjin Estuary which is restricted to access due to the confrontation between South and North Korea. Then we analyzed the forest fire severity and recoverability using atmospheric corrected Surface Reflectance Level-2 data collected from Landsat-8 OLI (Operational Land Imagery) / TIRS (Thermal Infrared Sensor). Normalized Burn Ratio (NBR), differenced NBR (dNBR), and Relative dNBR (RdNBR) were analyzed based on changes in the spectral pattern of satellite images to estimate burn severity area and intensity. Also, we evaluated the recoverability after a forest fire using a land cover map which is constructed from the NBR, dNBR, and RdNBR analyzed results. The results of dNBR and RdNBR analysis for the six years (during May 30, 2014 - May 30, 2020) showed that the intensity of monthly burn severity was affected by seasonal changes after the outbreak and the intensity of annual burn severity gradually decreased after the fire events. The regrowth of vegetation was detected in most of the affected areas for three years (until May 2020) after the forest fire reoccurred in May 2017. The monthly recoverability (from April 2014 to December 2015) of forests and grass fields was increased and decreased per month depending on the vegetation growth rate of each season. In the case of annual recoverability, the growth of forest and grass field was reset caused by the recurrence of a forest fire in 2017, then gradually recovered with grass fields from 2017 to 2020. We confirmed that remote sensing was effectively applied to research of the burn severity and recoverability in the DMZ. This study would also provide implications for the management and construction statistics database of the forest fire in the DMZ.

A Development of Consequence Analysis System for Combustible Materials Release Events Based on HTML5 Web (HTML5 웹 기반 가연성 물질 누출 피해영향평가 시스템 개발)

  • Lee, Ugwiyeon;Ji, Hyunmin;Oh, Jeongseok;Cho, Wansu
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.39-60
    • /
    • 2019
  • Korea Gas Safety Corporation is developing consequence analysis system for combustible materials release events to enhance risk assessment technology and its efficiency. Unlike general consequence analysis programs, the final consequence area was implemented through ETA analysis based on API-581 standard, and a convenient user interface was constructed based on HTML5-based responsive web technology. In addition, a phase equilibrium module using third-order state equations (such as Peng-Robinson, SRK, and RK) and fugecity was implemented to analyze the mixture quality. Also. using the consequence analysis algorithm introduced in CCPS books and TNO Yellow Book, we developed material leak analysis module, fireball, pool fire, jet fire, flash fire, and vapor cloud explosion consequence assessment module. In addition, the conditions for calculating the safety distance were prepared with using the control values in the EIGA standard, PAC, and Bevi Reference Book.

Implications of Multi-swarm Events Safety Management of Foreign Police (외국경찰의 대규모 행사 안전관리로 본 시사점)

  • Kim, Sang-Woon
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.8
    • /
    • pp.462-469
    • /
    • 2016
  • This study researched police intervention to ensure the safety of Multi-swarm events. And this study researched best practices of foreign countries. This study propose a solution. It used the situation to police intervention and domestic Multi-swarm events leading research and safety management systems. Safety management for multi-swarm events did ministry of public safety and security, local government, police department, fire department etc. Activities of Safety management for multi-swarm events was checked the risk level, safety management, safety planning and training, safety management in accordance with the Manual. But, safety management of police had Manual maintenance is necessary for the police forces and take advantage of, it is necessary to clarify the mission, it is necessary to configure the risk of a step-by-step checklist for police safety tips in detail. This study for solve the problem proposed the United States, United Kingdom, Germany, France, Australia, the case of the Japanese.

Fire Safety Analysis of Fire Suppression System for Aircraft Maintenance Hangar Using Fault Tree Method (Fault Tree를 활용한 항공기 격납고 소화시스템의 화재 안전성 분석)

  • Lee, Jong-Guk
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.67-73
    • /
    • 2017
  • An aircraft maintenance hangar is a building that stores, maintains, and inspects expensive aircraft. The frequency of fire occurrence is low, but the resulting human and material damage can be very serious. Therefore, in this study, we conducted a qualitative analysis of the fire safety of the currently operating fire suppression systems for aircraft maintenance hangars using the Fault Tree method, and then performed a quantitative analysis using the failure rate data for the derived basic events and analyzed the importance of the minimal cut sets. As a result of the qualitative analysis by the minimal cut set, it was found that there were 14 accident paths that could be expanded to a large fire, due to the fire control failure of the aircraft hangar fire suppression system. The quantitative analysis revealed that, the probability of the fire expanding into a large one is $2.08{\times}E-05/day$. The analysis of the importance of the minimal cut set shows that four minimal cut sets, namely the fire detector and foam head action according to the zone and blocking of the foam by the aircraft wing and the fire plume, had the same likelihood of causing the fire to develop into a large one, viz. 24.95% each, which together forms the majority of the likelihood. It was confirmed for the first time by fault tree method that the fire suppression system of aircraft maintenance hangars is not suitable for fires under the aircraft wings and needs to be improved.

A Study on Design and Implementation of an Analog Addressable Detector and a Fire Alarm System (아날로그 주소형 감지기와 자동화재탐지 시스템의 설계 및 구현사례에 대한 고찰)

  • Kim, Chong-Tai;Hong, Se-Kwun;Yoo, Young-Shin;Jung, Hae-Sung
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.1-11
    • /
    • 2010
  • This paper describes a design and implementation of an analog detector and a fire alarm system with recent technology on information and communication. A hierarchical architecture design from the detector to the main system enables to accommodate medium to large size buildings located nearby or far-away. And a software design from communication protocol to application program handles large amount of events efficiently to show information on a large LCD. A PC-based alarm system provides higher speed and larger capacity in a large LCD screen compared with foreign microprocessor-based small screen systems. Thus, very large buildings with several thousands of analog detectors can be easily covered in a single system. When an alarm occurs, a staff alarm scenario specially attempted only in the system is considered to play a major role to distinguish a real fire from unwanted alarms.

A Numerical Study for Fire Safety Evaluation of the Multi-story Residential Buildings -The Effects of the Openings of Stairwell on Fire Characteristics- (다세대주택의 화재안전평가에 대한 수치해석 연구 -계단실 개구부의 개폐가 화재특성에 미치는 영향-)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.15-23
    • /
    • 2007
  • In the events of a fire in the residential building, highly flammable polyurethane foam sofa produce toxic smokes. In this type of fire, the residents of the building can be gotten into the difficulties of evacuating from the fire places or may be to death due to a lot of hot toxic gases. In this study, CFD simulations were carried out to study the effects of the openings of stairwell on the fire characteristics of fire room and stairwell. Also, analysis of fire hazard based on the tenability limits of fire and FED(fractional effective dose) was performed to evaluate the life safety of the residents of the building. In the fire room, maximum temperature was about $290^{\circ}C$, maximum CO concentration was about 4,740 ppm, and the time to incapacitation of residents in fire room was about t=144 s. In the stairwell, temperature and CO concentration in the condition of openings to be open were even lower than those in it to be closed. Time to the tenability limit with respect to smoke visibility in the stairwell with openings, which was open, was shorter than that of it without openings to be open. It has been shown from this study that opening the stairwell openings is able to decrease the fire hazards to the life safety in the multi-story residential building fire.