• Title/Summary/Keyword: Fire evacuation

Search Result 703, Processing Time 0.031 seconds

The Counterflow Speed and Density of a Fire fighter in Corridor (복도에서 소방관에 의한 카운터플로우 발생 시 밀도와 속도 측정)

  • Kim, Woon-Hyung;Kim, Heung-Youl;Joung, Woo-In;Kim, Jong-Hoon
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.1
    • /
    • pp.76-83
    • /
    • 2019
  • Purpose: The purpose of this study is to present data of density and speed through the experiment of the counterflow by firefighter in corridor. Method: Experimental setup including a corridor in building was prepared for measuring data with 1.5m and 2m width. Normal flow and counterflow were created for each. Data were measured using camera and acquired by video image analysis. Results: The counterflow in corridor resulted in increasing average density of about $0.55P/m^2$ and decreasing average movement speed of about 0.61 m/s. These data measured during the time when the counterflow occurred. Conclusion: It was found that counterflow by firefighter in corridor momentary increasing the density and decreasing walking speed of evacuee. Further experiments of the counterflow effect in the total evacuation time are needed.

Correlation Analysis between BLE-based RSSI and SoC Internal or Local Temperature (BLE 기반 RSSI와 SoC 내부 또는 국부 온도의 상관관계)

  • Kim, Seong-Chang;Lee, Min-Jeong;Oh, Sung-Bhin;Kim, Jun-Su;Kim, Jin-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.89-91
    • /
    • 2022
  • Wireless sensor networks(WSN), which are mainly used for indoor positioning, rely on the accuracy of RSSI. This RSSI is sensitive to several factors that cause interference, and there are foreign studies showing that temperature has a large effect on RSSI in indoor/outdoor environment among several factors. The temperature of the indoor space is uneven due to heat sources or air cooling systems indoors, and temperature changes frequently occur at certain locations. In particular, in case of an indoor fire, the accurate positioning system is required to guide an evacuation route, but a high temperature is locally formed due to a fire around the receiver, so the RSSI value could be influenced. In this paper, the effect on RSSI is studied by analyzing the correlation between SoC internal/local temperature and RSSI.

  • PDF

Flow and smoke behavior of a longitudinal ventilation tunnel with various velocities using computational fluid dynamics (팬의 운전조건에 따른 종류식환기터널 내의 연기거동에 관한 전산유체역학연구)

  • Lee, J.H.;Kwon, Y.J.;Kim, D.E.
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.1
    • /
    • pp.105-115
    • /
    • 2014
  • A numerical analysis on the smoke behavior and evacuee safety has been performed with computational fluid dynamics. The purpose of this study is to build computational processes for an evacuation and prevention of a fire disaster of a 3 km-length tunnel in Korea. To save computational cost, 1.5 km of the tunnel that can include a few cross-passing tunnels is considered. We are going to assess the fire safety in a road tunnel according to the smoke level, which consists of the smoke density and the height from the floor. The smoke density is obtained in detail from three-dimensional unsteady CFD analysis. To obtain proper temperature distributions on the tunnel wall, one-dimensional conduction equation is considered instead of an adiabatic wall boundary or a constant heat flux. The tunnel considered in this study equips the cross passing tunnels for evacuees every 250 m. The distance is critical in both safety and economy. The more cross passing tunnels, the more safe but the more expensive. Three different jet fan operations can be considered in this study; under- and over-critical velocities for normal traffic condition and 0-velocoty operation for the traffic congestion. The SE (smoke environment) level maps show a smoke environment and an evacuating behavior every moment.

A study on the Optimum Capacity of Citadel (선원대피처의 적정규모에 관한 연구)

  • Kim, Won-Ouk;Chae, Yang-Bum;Kim, Chang-Jae
    • Journal of Navigation and Port Research
    • /
    • v.36 no.1
    • /
    • pp.21-26
    • /
    • 2012
  • Recently, vessel hijacking by pirates has been a big issue around the world. For example, the hostages of VLCC "SAMHO Dream" were released for a large sum of ransom. On January 20, 2011 "SAMHO Jewelry" succeeded releasing all of the 21 crews on the vessel by attacking the pirates in international waters for the first time since the founding of the Naval Force. Furthermore, the "HANJIN Tianjin" crews evacuated to the Citadel promptly and were rescued by the navy. As hijacking of Korean vessels by pirates is increasing, various safety measures must be implemented. As a matter of fact, the standard for ship's facilities has been partially revised and setting up an evacuation shelter on all vessels sailing dangerous zone has been reinforced. This research aims to discuss crew Citadel installation on vessels intended for long haul. In addition, it will look at measures against potential gas flow in the event of pirate armed attacks and fire outbreak onboard a vessel. It will also assess the optimal number of crew Citadels theoretically. Lastly, the optimal number of shelters in the event of fire outbreak will be discussed based on an FDS simulation.

Evaluation of Smoke Control Performance of Ventilation System Using by Hot Smoke Test (Hot Smoke Test를 이용한 주차장 환기설비의 제연 성능평가)

  • Joung, Suckhwan
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.2
    • /
    • pp.47-56
    • /
    • 2019
  • Recently, in order to overcome the difficulty of entering a fire source due to the occurrence of a large amount of smoke in the event of a fire in a parking lot, it has used that a method of discharge smoke using air supply, exhaust fans and jet fans installed for ventilation of parking lots. In this study, the variation of flow in the smoke layer was observed using CCTV under two conditions, in which only the air supply fan operates and the manned fan operates together, and the temperature around the plume was compared to Albert eq. to assess its suitability as a parking lot ventilation performance evaluation method. As a result, it was found that the smoke layer could be disturbed if the Jet Fan was operated at the same time, which could lead to the possibility of an initial evacuation disturbance. However, the additional operation of the Jet Fan has been confirmed by the observation CCTV that the emission performance is improved, which is believed to help conduct the suppression operation. The temperature around the plume was measured and compared to Alpert eq, and was analyzed to be about $2^{\circ}C$ lower at the center axis of the plume and $9.0^{\circ}C$ higher at 8 m in the direction of the discharge of smoke. The results of temperature measurements around the plume were lower than the maximum temperature expected in AS 4391 and did not exceed the expected temperature risk caused by the experiment. As with these results, the temperature risk from the progression of hot smoke tests is foreseeable, so it will be available as one of the general evaluation methods for assessing smoke control performance in a parking lot without relevant criteria.

An Implementation of Congestion-based Server System for LBS Fire Evacuation Service (위치기반 화재대피 서비스를 위한 혼잡도 기반 서버시스템 구현)

  • Song, Dong-Hyuk;Min, Jin-Ki;Seo, Hyo-Seung;Lee, Joon-beom;Kim, Hyeon-Jung;Son, Bong-Ki;Lee, Jaeho
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.10a
    • /
    • pp.452-454
    • /
    • 2016
  • 화재와 지진 등 재난 발생 시 인원이 많이 밀집되어 있는 건물 내에서는 혼란스러운 상황이 발생하는 것이 일반적이고 각 건물 내 사람들이 통솔하기도 어렵다. 이러한 문제를 해소하기 위해 본 논문에서는 상황에 따른 장치 간 전송하는 데이터를 나누어 데이터 전송에 효율성을 높이며 데이터베이스를 제안하여 데이터 간 관련성과 관리에 효율성을 높이고 사용자에게 직접 건물 내 상황을 알리고 안정적으로 대피를 할 수 있도록 도움을 주는 기술과 그에 필요한 Protocol을 제안한다.

Examination for Methodology of Design of Emergency Lightings by Using Space Syntax Theory (공간구문론을 이용한 지하공간 비상유도등의 효율적인 위치선정 방법론 검토)

  • Won, Seul-Ki;Kim, Young-Uk;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.1-9
    • /
    • 2006
  • The emergency lighting plan for underground space should be done with consideration of characteristics of the space. In terms of utilizing the Depthmap program from the Space Syntax theory, it is possible to analyze space quantitatively. Integration and intelligibility are major induces of this theory and we can use them as emergency lighting design parameters. For this study, human behaviors and survivor's evacuation routes in fire emergencies are analyzed through literature review. Based on those results, this study suggests the methodology of emergency lighting plan in underground space.

A basic study on improvement of Disasters Prevention System using space information from 3D CAD - focused on Multiple-use Facilities - (3D CAD 공간 정보를 활용한 방재 시스템 개선에 관한 기초 연구 - 다중이용시설물 중심으로 -)

  • Lee, Myoung-Hoon;Ahn, Byung-Ju;Kim, Jae-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.189-193
    • /
    • 2009
  • As large-scale buildings, skyscrapers, and multi-purpose buildings recently increase in numbers dramatically the internal space of such buildings becomes more and more large and complicated accordingly. The Multi-purpose buildings are increasing rapidly in number, and concerns over the evacuation process in case of fire emergency are also increasing. However, A controller who is responsible for visitor's safety makes a decision about measures for visitor safety in human based decision making process. Many potential accidents that are caused by human error lurk in results of the process. The accidents can be decreased by changing the decision making process from human-based into technology-based. Through this study, the way to improve current disasters prevention system is presented and it can also improve shelter inducement methods effectively. SICS(Spatial Information Control System) which is being studied in other research is used as the tool for improvement.

  • PDF

Fire and Evacuation Simulation Analysis of Large-Scale Domestic Data Centers (국내 대규모 데이터센터 화재 및 피난 시뮬레이션 분석 )

  • Kim, Dong-Min;Go, Eun-Seong;Park, Hyeong-Gyoon;Gwak, Ji-Hyeon
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.347-348
    • /
    • 2023
  • 본 논문에서는 실제 규모 데이터센터의 3D 모델링을 기반으로 대상 공간별 화재 시나리오를 선정하여 화재 및 피난 시뮬레이션을 수행하였다. FDS와 Pathfinder는 full coupling 방식을 사용할 수 없는 한계가 있으며 semi coupling의 경우 가시화에는 도움이 되나 결과에 영향을 주지 않는다. 따라서 재실자의 피난 상황 시 경로에 대한 안전성과 화재 위험 노출 정도를 시각적으로 분석하는 것이 가능한 semi coupling과 시뮬레이션 결과 데이터 분석을 병행하여 수행하였다. 전산실의 경우 서버의 기능상실 한계 온도가 32도이기 때문에 서버 기능 정지 상황에 도달하는 시간을 중점적으로 분석하였다. 전산실은 업무 및 고객 서비스와 관련된 모든 데이터들을 저장하기 위해 항시 기동 되어야 하는데 전산실 내 화재가 발생할 경우 1~2분 이내 서버 기능이 정지되는 상황이 발생하였다. 따라서, 서버가 안전하게 계속 동작하기 위해서는 전력 계측 및 제어 케이블 열화, 서버 장치의 건전성이 유지되어야 하며 초기 화재를 빠르게 감지하여 진압하여야 한다. 피난 시뮬레이션의 경우 가시도를 상실하게 되는 시간이 약 195초(5m 미만) 인근으로 인원이 해당 층을 완전히 벗어나는 데 걸리는 시간이 약 125.6초였던 것을 보면 대피하기에 충분한 허용 피난시간(ASET)을 확보하고 있음을 알 수 있었다.

  • PDF

Counter Measures of the Subway Terrorism through Case Analysis (사례분석을 통한 지하철 테러에 대한 대책)

  • Kwon, Jeong-Hoon;Kim, Tae-Hwan;Choi, Jong-Gyun
    • Korean Security Journal
    • /
    • no.18
    • /
    • pp.1-20
    • /
    • 2009
  • Nowadays most nations around the world including Korea have experienced absolute shortages of available urban space. To solve various problems of the city, each nation constantly tends to extend the underground space. However there is a serious problem in making use of the underground space. Especially new terrorism coming into existence after 9.11 terror turns into the so-called ‘soft target’ which has something to do with public transportation facilities available to most people. Good examples are like these: poisonous gas attacks in Tokyo subway in 1995, Daegu subway station fire in 2003, serial bomb blast of London subway in 2005. In spite of being a concern on incidents related to the underground space it is inevitable to utilize the underground space and the tendency is growing. But Korea lags badly behind in foreign countries in this field and so seeking measures is urgently needed. Therefore the aim of this study is to note visible damages stemmed from the domestic and foreign underground space and propose more effective and adequate measures. Safety measures of terrorism are associated to minimize damage out of terrorism and they are as follows. In the first place, preparing protective equipment for saving a life from fire attacks and poisonous gas is needed urgently. In the second place, counterpart management on the spot and systematic security training should be established in order to minimize injury. In the third place, fire escapes must be provided for a rapid evacuation of potential unspecified individuals. In the fourth place, building up a network of related institutions is required for a systematic omnidirectional counterpart. Finally the Korean government ought to take fast and appropriate actions for the injured and bereaved family of the terror incident.

  • PDF