• Title/Summary/Keyword: Fire development

검색결과 1,663건 처리시간 0.031초

하이브리드 인터락을 적용한 점화회로 설계 (The Design of Squib Circuit using Hybrid Interlock)

  • 장부철;조길석;신진범;구봉주
    • 한국군사과학기술학회지
    • /
    • 제17권4호
    • /
    • pp.404-412
    • /
    • 2014
  • We proposed a design method for squib current supply & interlock circuits in guided-missile fire control systems. In order to design squib current supply circuits, various missile squib loads including line resistance and squib devices have to be considered in advance minimizing probability of redesign of circuits and reducing the development cost by implementing the most proper squib current supply circuit. Also, we presented a hardware interlock logic instead of the commonly used software safety logic to improve the safety of guided-missile fire control systems. The proposed squib interlock circuit enhances safety requirements of guided-missile fire control systems. We confirmed that simulation and measurement results of the proposed design method are the same as theoretical analysis results.

고강도콘크리트 내화성능을 확보한 건식화 PFB 공법 개발에 관한 연구 (A Study on the Development of a Dry PFB Method with High Fire Resistance)

  • 김우재;정상진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.49-52
    • /
    • 2008
  • The present study was to develop a dry PFB method similar to the existing gypsum board construction method in order to apply the existing wet PFB method that uses fire-resistant adhesive. It was found that the existing wet method can produce concrete compressive strength of 80MPa and fire resistance of 3 hours with 30mm PF boards. The goal of development in this study was fire resistance of 3 hours through dry construction of 15mm fire-resistant boards. 1. Improved PF board was prepared by adding inorganic fiber to existing board and using aggregate with grain size of 3mm or less. Molding was done at temperature higher than that for existing PF board molding. While wet curing is used for existing PF boards, this study used dry curing in order to enhance heat insulation performance. 2. According to the results of fire resistance test, when the dry PF method was applied, the temperature of the main reinforcing bar was 116℃ in 15mm, 103.8℃ in 20mm, and 94℃ in 25mm, and these results satisfied the current standards for fire resistance control presented by the Ministry of Land, Transport and Maritime Affairs. When a 3-hour fire resistance test was performed and the external properties of the specimen were examined, the outermost gypsum board hardly remained and internal PF board maintained its form without thermal strain.

  • PDF

밀폐공간에서 액체연료 화염의 거동에 관한 실험적 연구 (An Experimental Study on the Behavior of Liquid Fuel Flames in the Confined Space)

  • 전길송;황지현;이태원
    • 한국안전학회지
    • /
    • 제36권2호
    • /
    • pp.87-93
    • /
    • 2021
  • Modern society shows rapid growth that is different from that of the development of existing technologies. The development of these technologies has led to the tendency of buildings to become dense, large and advancing. Regarding fire hazards, the possibility of large-scale fires causing fatal damage, due to the rapid spread of fire, increases. Therefore, for this reason, fire defense, i.e. detection and fire extinguishing facilities, in buildings are essential and well applied. But there are always limitations to that. Based on this reason, we would like to suggest the introduction of a new concept of a fire safety system. The method presented here is not only to use a single system for fire detection and fire extinguishing systems but to jointly use it in the environment and energy management fields within the building. However, an important step is required before introducing a system of these technologies. The fire extinguishing method proposed by this system is a method of extinguishing by blocking oxygen flowing into the space where the fire occurred. However, a sufficient basis is needed for this system to be applied in practice. Therefore, in this study, we intend to conduct a preliminary experiment to introduce the new concept of fire detection and extinguishing. The experiment used ethanol with a relatively simple combustion reaction and a high possibility of complete combustion. As a result, it was confirmed how the internal values changed during a fire using ethanol. Resultingly, we obtained the internal oxygen concentration and internal environmental changes according to the initial flame size. Lastly, the data accumulated in this study can be used as data for application in an automatic fire extinguishing system.

Numerical Simulations of the Supersonic Jet Impingement in a Confined Plenum of Vertical Launching System

  • Lee Kwang-Seop;Lee Jin-Gyu;Hong Seung-Kyu;Ahan Chang-Soo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2006년도 PARALLEL CFD 2006
    • /
    • pp.301-305
    • /
    • 2006
  • The Vertical Launching System design is especially complicated by complex flow structure in a plenum with the severe thermal state and high pressure load form the hot exhaust plume. The flow structures are numerically simulated by using the commercial code, CFD-FASTRAN with the axi-symmetrical Navier-Stokes equations. Two different cases are considered; that is, the stationary fire and the moving fire.

  • PDF

퍼지논리 및 다중신호를 이용한 화재감지시스템의 개발 (The Development of Fire Detection System Using Fuzzy Logic and Multivariate Signature)

  • 홍성호;김두현
    • 한국안전학회지
    • /
    • 제19권1호
    • /
    • pp.49-55
    • /
    • 2004
  • This study presents an analysis of comparison of P-type fire detection system with fuzzy logic-applied fire detection system. The fuzzy logic-applied fire detection system has input variables obtained by fire experiment of small scale with K-type temperature sensor and optical smoke sensor. And the antecedent part of fuzzy rules consists of temperature and smoke density, and the consequent part consists of fire probability. Also triangular fuzzy membership function is used for input variables and fuzzy rules. To calculate the final fire probability a centroid method is introduced. A fire experiment is conducted with controlling wood crib layer, cigarette to simulate actual fire and false alarm situation. The results show that peak fire probability is 25[%] for non-fire and is more than 80[%] for fire situation, respectively. The fuzzy logic-applied fire detection system suggested here is able to distinguish fire situation and non-fire situation very precisely.

전자식 점화안전장치 회로부 설계 및 검증 (The Design and Test of the Electronic Arm Fire Device Circuit)

  • 김학성;황정민;장승교;김재훈;황대규
    • 한국군사과학기술학회지
    • /
    • 제21권6호
    • /
    • pp.857-864
    • /
    • 2018
  • This paper describes about the circuit design and test of the electronic Arm Fire Device. Electronic arm fire device consists of igniter, circuit and housing case and it operates without the actuator such as torque motor or solenoid. A high-voltage DC-DC converter was used to generate the voltage for initiating the LEEFI(Low Energy Exploding Foil Initiator). The MEMS switch was used to detect the acceleration that occurs when missile is launched, and the circuit was designed considering the size, performance, and specification of the electronic devices. The performance test was conducted to verify the designed circuit and we confirmed that it operates well.

소방법규해석에 대한 EXPERT SYSTEM의 적용 (The Application of Expert System in Fire Code Analysis)

  • 김회천;손재열;김화중;박병윤
    • 한국화재소방학회논문지
    • /
    • 제3권3호
    • /
    • pp.9-13
    • /
    • 1989
  • This paper realizers expert system which is searched most suitable system of the fire facilities by regulating of fire operating order And so, the user finds the inference, heuristic knowledge of the expert who has a mastery of application of the fire code objected protection, warning or extinguishing of fire. Although some expert systems utilize artificial intelligence such as LISP or PROLOG, this study utilizes M.1 that is available expert system development tool running with personal computer.

  • PDF

DATA BASE SYSTEM DEVELOPMENT AND STATISTICAL ANALYSIS OF EIR3 ACCIDENTS OF SEVERAL COUNTRIES

  • Kim, In-Tae;Kim, In-Won;Song, Hee-Oeul
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.319-326
    • /
    • 1997
  • The fire accident cases of several countries such as Korea, Japan, United States, etc., were collected and compared statistically. The trends of fire accidents in several countries will help us establish detailed plans for fire protection and reduce the possible fire accidents in the future. For construction of data base system, the program FADS was developed, which is operable in Windows environment.

  • PDF

국민안전처 소방안전분야 연구개발사업(2012년~2014년)의 성과분석 (Accomplishment Analysis of the Fire Fighting and Safety Research Development Program Supported by Ministry of Public Safety and Security (2012-2014))

  • 정재한;한용택
    • 한국화재소방학회논문지
    • /
    • 제30권4호
    • /
    • pp.141-147
    • /
    • 2016
  • 국민안전처에서 수행하고 있는 소방안전 연구개발사업 주요 내역사업으로는, 화재예방 및 경계기술개발, 특수재난 진압 대응 기술개발, 인명 구조 구급 및 현장대응요원 안전확보 기술개발 등 세개 내역사업으로 구성되어 2007년부터 수행하고 있다. 주요 성과지표로는 (1) 국내외 특허, 실용신안, 디자인(의장) 등 산업재산권 출원/등록 건수 (2) 현장실험, 상용화를 위한 성능기준 확보, 시제품 개발, 소프트웨어 등록, 기술료 발생건수 (3) 수행과제와 관련하여 국내외 학술지에 게재된 연구논문 및 수행과제 결과물을 이용한 정책활용 건수 (4) 연구과제 수행기간 동안 발생된 고용창출 및 인력양성 실적 등으로 구성되어 있다. 본 연구에서는 2012년부터 2014년까지 수행한 소방안전분야 연구개발사업의 특허 성과, 논문 성과, 소프트웨어 등록 성과에 대해 조사 분석하였다.