Performance Based Design Plan for Apartment that Reflects External Effects from Toxicity and Radiant Heat Due to Acrylonitrile Leakage (아크릴로니트릴 누출에 따른 독성, 복사열 및 외부영향에 의한 아파트의 성능위주설계 방안)

  • Seongju Oh;Sanghun Han;Hasung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.2
    • /
    • pp.65-77
    • /
    • 2024
  • This study aims to present a performance based design for apartments through evacuation safety assessment and damage impact assessment due to acrylonitrile leakage. In the evacuation safety evaluation, ASET was analyzed as 25 min or more and 60 min or less when the ventilation rate was once per hour, and RSET was 22.6 min. Evacuation safety is satisfied when the number of ventilation per hour is less than 1, so it is necessary to design the number of ventilation to be 1 or less. In the damage impact assessment, the 0% structural collapse rate due to overpressure was measured to be between 71m and 90m, and the 0% fatality rate due to radiant heat was measured to be between 136m and 353m. Therefore, maintain a safe distance of 353m or more.

Experimental Studies on PSC Airpit-Slab with Fire Resistance Panel under Static and Dynamic Loads (내화패널이 부착된 프리캐스트 PSC 풍도슬래브의 정적/동적하중에 관한 실험연구)

  • Kim, Tae Kyun;Bae, Jeong;Choi, Heon;Min, In Gi
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.4A
    • /
    • pp.245-253
    • /
    • 2012
  • In the longway tunnel and underground traffic road, the structure of transverse ventilation system is constructed by the airpit slab. In this study, the full scale specimens of the PSC airpit slab that attached fire resistance panel are performed the static and dynamic loading tests for evaluation of bending capacity. The first of all, it confirmed the evaluations about the fundamental efficiency of the fire resistance panel and PSC slab by the 3-point bending test and pull-off test. The tests are performed for evaluation of the bending resistance under ultimate static load and the bonded capacity under dynamic fatigue load. A fatigue test is performed for an investigation of the effect on wind pressure that is developed by transit of traffic. The damage or debonding on surface between fire resistance panel and PSC slab was not developed in dynamic fatigue load test, also the behavior of the specimens is very stable and the debonding of the fire resistance panel attached at the bottom surface of PSC slab was not developed in static load test, too. Therefore, the crack or debonding of the fire resistance panel will be not developed by external loads during the construction or completion of the precast fire resistance system.

Necessity of Korean Integrated Life Safety Code and Fire Safety Performance Evaluation Technology (한국형 통합 인명안전코드 및 화재안전 성능평가기술의 필요성)

  • Kwon, Young-Jin;Koo, In-Hyuk;Jin, Seung-hyeon;Lee, Byeong-Heun;Kim, Yun-Seong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.50-51
    • /
    • 2020
  • Recently, construction projects are gradually becoming high-rise and large-scale, and furthermore, the use of new buildings is emerging through the deepening of the underground. In this situation, a lot of fire damage has occurred in recent years, mainly in buildings and tunnel structures. In particular, damages caused by fires during large-scale construction projects such as freezing warehouse accidents are increasing. In this situation, in Korea, it is still trying to secure safety from human fire through the administrative system divided into the building law and the fire law, but it is being developed in a negative direction rather than a positive direction. The fire risk is getting bigger even when the road is not maintained. In this current situation, it is considered that the development of a Korean integrated life safety code centering on the consciousness base of Koreans will be necessary, and in particular, the ease of revision will also be needed by promoting the integrated safety code rather than current laws and regulations. This is a summary of the future tasks.

  • PDF

Probabilistic Risk Evaluation Method for Human-induced Disaster by Risk Curve Analysis (확률.통계적 리스크분석을 활용한 인적재난 위험평가 기법 제안)

  • Park, So-Soon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.6
    • /
    • pp.57-68
    • /
    • 2009
  • Recently, damage scale of human-induced disaster is sharply increased but its occurrences and damages are so uncertain that it is hard to construct a resonable response & mitigation plan for infrastructures. Therefore, the needs for a advanced risk management technique based on a probabilistic and stochastic risk evaluation theory is increased. In this study, these evaluation methods were investigated and a advanced disaster risk evaluation method, which is based on the probabilistic or stochastic risk assessment theory and also is a quantitative evaluation technique, was suggested. With this method, the safety changes as the result of fire damage management for recent 40 years was analyzed. And the result was compared with that of Japan. Through the consilience of the traditional risk assessment method and this method, a stochastical estimation technique for the uncertainty of future disaster's damage could support a cost-effective information for a resonable decision making on disaster mitigation.

An Experimental Study on Fire Spreading External Wall of Buildings Using Dry Construction Method (건식공법을 이용한 건축물의 외벽 화재 확산의 실험적 연구)

  • Park, Jung-Woo;Cho, Nam-Wook
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.75-85
    • /
    • 2018
  • The Grenpell tower fire in England in June of 2016 is a representative example of damage caused by a vertical fire spreading through external insulation. Organic insulation materials, which are widely used in external insulation, have the disadvantage that they have good insulation performance but are vulnerable to fire. Aluminum composite panels are used as exterior wall finishing materials, and plastics used in aluminum are regarded as the cause of vertical fire spread. Due to the steel frame used to secure the aluminum composite panel to the outer wall, a cavity is formed between the outer wall and outer wall finish. When a fire occurs on the outer wall, the flammable outer wall as well as the flame generated from the heat-insulating material spreads vertically through the cavity, resulting in damage to people and property. In Korea, material unit performance tests are carried out by the Ministry of Land, Infrastructure and Transport notice 2015 - 744. However, in the UK, the BS 8414 test is used to measure the vertical fire spreading time on the outer wall in real scale fire tests. In this study, the risk of external wall fire was evaluated in an actual fire by conducting a real scale wall fire test (BS 8414), which was carried out in Europe, using aluminum composite panels of semi-noncombustible materials suitable for current domestic standards. The purpose of this study was to confirm the limitations of material unit evaluation of finishing materials and to confirm the necessity of introducing a system to prevent the spread of outer wall fire through an actual scale fire test.

Analyzing The Economic Impact of The Fire Risk Reduction at Regional Level in Goyang City (지역단위 화재 위험도 저감의 고양시 경제적 파급효과 분석)

  • Son, Minsu;Cho, Dongin;Park, Chang Keun;Ko, Hyun A;Jung, Seunghyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.685-693
    • /
    • 2021
  • This study examined the fire risk of the region in Goyang City using the spatial information data of buildings. The economic damage by industry was assessed according to the probability of fire risk. The study area was confined to Goyang-si, Gyeonggi-do, and the same fire risk reduction rate was applied to each region for the convenience of analysis. The possibility of fire was derived based on the buildings' density and usage in the area by National GIS building-integrated information standard data. The calculation of economic damage by industry in Goyang City due to the fire risk was calculated by combining the Goyang-si industry-related model produced by matching with 30 industrial categories in Input-Output Statistics of Korea Bank and 20 industrial categories in the Goyang-si business survey and the possibility of fire. The basic scenario of production impossibility during six months and business loss due to fire was established and analyzed based on the supply model. The analysis showed that Ilsan-dong-gu, Ilsan-seo-gu, and Deokyang-gu suffered the most economic damage. The "electricity, gas, steam, and water business" showed the greatest loss by industry.

A Study on Types of Disasters Affecting City Safety (도시안전에 영향을 미치는 재난유형에 관한 연구)

  • Choi, Yun-Cheul
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.6
    • /
    • pp.93-100
    • /
    • 2019
  • Modern society is transforming into an extreme climate environment. This is fatal to humans and ecosystems and is expected to cause large-scale damage. As this spokesman, natural disasters are increasing as this global average temperature rises. Social and economic damage by this tendency is also increasing. In addition, the frequency and scale of social disasters are increasing. Damage to the living area due to the damage of the infrastructure due to the increased reliance on infrastructure has been increasingly enlarged. In this research, various disasters such as natural disasters and social disasters analyze the impact on urban safety. A local autonomous entity K Priority Management Establish a kind of disaster, prepare crisis management manual, and use it as a basic material of education / training.

Performance Analysis for Fire Suppression and Disaster Management R&D Projects (소방·방재 R&D 성과분석 연구)

  • Yoon, Jonghyun;Kim, Geunyoung;Lim, Hyeounjoon
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.2
    • /
    • pp.208-218
    • /
    • 2014
  • The growth of disaster/accident damage costs and related industries has increased the necessity of scientific and objective performance analysis for fire suppression and disaster management R&D projects. Most of R&D performance are both academic and public performance according to fire suppression and disaster management R&D projects during the period of 2004 to 2011. This research identified characteristics of performance types by research project teams and research development stages. The research outcome shows the usefulness of relevant performance objective settings by project teams, the evaluation of scientific technology fields, and proper research teams in research team selection process, considering research outcome characteristics by both research teams and research development stages. In addition, this research reveals the applicability of research outcomes to research performance management. This research suggests further studies for evaluation process and methods for including fire suppression and disaster management characteristics to the evaluation process.

A Study on the Risk Management Information System of the Underground Space - focused on Fire Growth Risk Assessment System- (지하공간의 위험관리정보시스템에 관한 연구 -화재확산평가시스템 중심으로-)

  • 박종근;노삼규
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.49-58
    • /
    • 2002
  • A large number of accidents at an underground place have been happening, including the gas explosion under construction of subway; the fires of underground utility and underground shopping malls, and other explosion, at home and abroad recently. These accidents make the function of a city ineffective due to the paralyses of electricity and communications net as well as the loss of property and cause people to feel unsecured with accompaniment of a heavy of toll of lives. This research will show evaluation methods of a numerical value of expected average loss space of combustion with the use of probability in order to present potential risk of combustion growth that underground space might cause, and how designer decides a system that enables us to compare and evaluate relatively the effectiveness of measures for preventing burning by calculating the expansion route and the damage size of burning in case of fire.

An Experimental Study on the Fire Damage Evaluation of the Concrete Lining (콘크리트 라이닝의 화재손상 평가에 관한 실험적 연구)

  • Park, Kyung-Hoon;Kim, Heung-Youl;Yoo, Yong-Ho;Kim, Hyung-Jun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.201-206
    • /
    • 2011
  • 최근 국내에서는 대심도 터널 시공계획이 발표되면서 터널 구조물에 대한 방재 및 내화설계에 대한 관심이 높아지고 있다. 화재 발생 시 문제가 발생할 수 있는 콘크리트 라이닝의 내화설계를 위해서는 보다 구체적인 내화성능을 측정하기 위한 내화실험이 실시되어야 한다. 현재 국내에서는 건축물의 내화성능을 평가하기 위한 시험평가 방법이 제시되어 있는 상태이나 터널 구조물에 대한 시험법이나 성능평가는 거의 전무한 상황이다. 따라서 본 연구에서는 콘크리트 구조물의 화재손상 정도를 평가하기 위해 현장에서 사용되고 있는 터널 라이닝을 대상으로 화재 시 콘크리트 라이닝의 손상정도를 평가하였다. 실험은 대표적인 터널 화재시나리오 곡선인 RABT 화재 시나리오를 적용하였으며 폭렬방지에 효과적인 것으로 알려져있는 fiber cocktail(강섬유+폴리프로필렌섬유)의 혼입여부에 따른 성능평가도 함께 실시하였다.

  • PDF