• Title/Summary/Keyword: Fire damage characteristics

Search Result 183, Processing Time 0.033 seconds

Fire Resistance Characteristics of Firewall Structure Associated with Impact Damage Induced by Explosion

  • Hye Rim Cho;Jeong Hwa Yoo;Jung Kwan Seo
    • Journal of Ocean Engineering and Technology
    • /
    • v.37 no.3
    • /
    • pp.99-110
    • /
    • 2023
  • When a fire accident accompanied by an explosion occurs, the surrounding firewalls are affected by impact and thermal loads. Damaged firewalls due to accidental loads may not fully perform their essential function. Therefore, this paper proposes an advanced methodology for evaluating the fire resistance performance of firewalls damaged by explosions. The fragments were assumed to be scattered, and fire occurred as a vehicle exploded in a large compartment of a roll-on/roll-off (RO-RO) vessel. The impact velocity of the fragments was calculated based on the TNT equivalent mass corresponding to the explosion pressure. Damage and thermal-structural response analyses of the firewall were performed using Ansys LS-DYNA code. The fire resistance reduction was analyzed in terms of the temperature difference between fire-exposed and unexposed surfaces, temperature increase rate, and reference temperature arrival time. The degree of damage and the fire resistance performance of the firewalls varied significantly depending on impact loads. When naval ships and RO-RO vessels that carry various explosive substances are designed, it is reasonable to predict that the fire resistance performance will be degraded according to the explosion characteristics of the cargo.

A Study on the Analysis of Fire Risk for each Building Usage Based on the Reliability of Operation of Fire Protection System (소방설비 작동신뢰성 기반 건축용도별 화재리스크 분석에 관한 연구)

  • Jin, Seung-hyeon;Kim, Hye-Won;Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.113-114
    • /
    • 2020
  • In the design and maintenance of buildings, identifying the degree of damage in the event of a fire is an important factor in fire prevention and fire safety design. In order to predict fire damage, safety measures should be established by predicting the nature of evacuation according to fire, smoke and in-house characteristics, and the effects of the operation of fire safety facilities should also be considered, but in Korea, the risk analysis due to the operation of fire safety facilities is insufficient. Accordingly, this study uses fire statistics and sprinkler inspection data to analyze the degree of fire damage caused by the operation of sprinkler facilities in a probabilistic manner.

  • PDF

Analyses on Related Factors with Fire Damage in Korea (한국에서의 화재 피해 관련요인 분석)

  • Chang, Eunmi;Kang, Byungki;Park, Kyeong
    • Journal of the Korean Geographical Society
    • /
    • v.50 no.3
    • /
    • pp.355-373
    • /
    • 2015
  • In this study the factors of fire damage are analyzed through previous research reviews. Local environmental factors as well as those factors attributed to fire damage (number of fire events, number of injured, number of death, economic loss) were selected to compose mutual relationship model. In order to verify this relationship model, official statistics concerning fire damage were collected from 228 local governments and compared with results from previous research. As a result of this comparison four dependent variables and 22 independent variables that affect fire damage were analyzed. Independent variables are divided into human vulnerability factors, physical vulnerability factors, economic vulnerability factors, mitigating factors and local characteristics. To analyze a relationship between selected dependent variables and independent variables, we applied a semi-logarithm model and performed regression analysis. Among the 22 independent variables, the number of the weak to disaster, social welfare service workers, workers in manufacturing industry, and the number of workers in restaurants and bars per 10,000 people show the significant correlation with the number of fire incidence. The number of death from fire is significantly related to two variables which are the number of social welfare service workers per 10,000 and the ratio of commercial area. Damage cost is significantly dependent on the property taxes per 10,000 people. These factors were included in the research model as vulnerability factors (human, physical, economic) and mitigating factors and local characteristics, and the validity of research model was verified. The result could contribute to fire-fighting resource allocation in Korea or they can be utilized in establishing fire prevention policy, which will enhance the national level of fire safety.

  • PDF

An Experimental Study on Thermal Damage and Spalling of Concrete Lining in Tunnel Fire (터널화재시 콘크리트 라이닝의 폭렬 및 화재손상에 관한 실험적 연구)

  • Kim, Heung-Youl;Kim, Hyung-Jun;Cho, Kyung-Suk;Lee, Jae-Sung;Kwan, Ki-Hyuk
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.110-120
    • /
    • 2009
  • In tunnel, though the frequency of fire occurrence is relatively lower than other structures, the characteristics of sealed space tends to cause the temperature to rapidly rise to more than $1000^{\circ}C$ within 5minutes after fire, which might eventually lead to a large fire that usually results in a loss of lives and the damage to the properties, not to mention a huge cost necessary for repair and maintenance after fire. We have developed various conditions of the heating furnace and the method to install a thermo couple within the furnace based on EFNARC and KS F 2257-1. Referring to tunnel fire scenarios, it clarified the heat transfer characteristics of concrete PC panel lining depending on fire intensity (ISO, $1^{\circ}C$/SEC, MHC, RWS), and to identify the range of thermal damage, the evaluation was carried out using ITA standard. As a result, 30mm under ISO fire condition, 20mm under $1^{\circ}C$/SEC, 100mm under MHC and 50mm under RWS were measured. And when it comes to spalling, 30mm was measured under RWS and MHC.

A Study on the Risk Analysis of Building Fire Using Statistical Data of Casuals (사상자 통계자료를 활용한 건축물 화재 위험성 분석에 관한 연구)

  • Jin, Seung-hyeon;Kim, Hye-Won;Koo, In-Hyuk;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.48-49
    • /
    • 2021
  • The purpose of evaluating the fire risk of a building is to predict damage or loss of life and property in unspecified circumstances and to minimize expected damage. The fire risk assessment for buildings in Korea analyzes fire risk according to performance-oriented design under the Enforcement Decree of the Fire Facilities Act and the Fire Causing Index under the Enforcement Decree of the Multi-Use Business Act. Fire risk analysis is mainly conducted by using fire statistics or analyzing the results of safety inspections of buildings. In the case of fire statistics, it is necessary to analyze the fire risk in consideration of the degree of fire damage in each number of fires, as all fires received by the fire department are collected. In addition, it is necessary to devise fire safety measures for buildings by predicting the number of casualties that may occur due to fires in each building. Accordingly, this study aims to analyze the characteristics of casualties by building use using the number of fires judged to have grown.

  • PDF

The Analysis of Distribution and Characteristics of Forest Fires Damage over 30 ha in Korea (우리나라 30 ha 이상 산불피해의 분포 및 특성 분석)

  • Lee, Hyung-Seok;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.39-46
    • /
    • 2011
  • In order to consider the prevention countermeasure to the occurrence of forest fires, analysing characteristic of the past forest fire data is needed. This research analyzed distribution and characteristics of forest fires damage over 30 ha based on statistics data of forest fires in Korea between 1975 and 2010. As a result, the number of forest fires damage over 30 ha as 23 was most occurred in 1978. Forest fires show an upward tendency from 1970 to 2000. Forest fires of 30 ha~50 ha damaged area was most occurred. Forest fire in Gangwon province was occurred as the number of total 66 (37.0 %). Gangwon province was superior in point density analysis. The number of forest fire occurrence over 30 ha was most high to 114 (63.0 %) in April and to 44 (24.3 %) in Sunday. The occurrence number of forest fire and damage caused by forest fire is increasing more and more since 1975, appropriate authorities can use effectively in devising policy for forest fire prevention from this result.

Comparative analysis of forest fire danger rating on the forest characteristics of thinning area and non-thinning area on forest fire burnt area (산불피해지역에서 숲 가꾸기 실행유무가 산불에 미치는 영향)

  • Lee, Si-Young;Lee, Myung-Woog;Yeom, Chan-Ho;Kwon, Chun-Geun
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.153-156
    • /
    • 2008
  • Comparative analysis of forest fire danger rating on the forest characteristics of thinning area and non-thinning area on forest fire burnt area was studied in this work. To investigate the effect of thinning slash in forest fire, Gangneung-si Wangsan-myeon, Ulgin-gun Wonnam-Myeon, Samchok-si Gagok-Myeon, in which forest fire broke out, were selected. As a result that investigated forest fire danger ratio between thinning slash and non-thinning slash, leeward scorching ratio(36%), crown damage ratio(29%), mortality of branch at the former are higher than those at the latter, leeward scorching ratio of tree, where thinning slash is around, is 10%-20% higher than that of independent tree. So I estimate that thinning slash has a some effect on the intensity of forest fire. And the result to investigate damage of forest fire according to tree species shows that leeward scorching ratio of conifer is 5% higher than that of non-conifer, and mortality of branch of the former is 19% higher than that of the latter. It is considered that forest fire may affect directly to a tree trunk if it diffuse to piled thinning tree because there was no space between thinning trees and trees. Furthermore, it was found that re-ignition had a chance to occur due to lots of piled thinning trees.

  • PDF

THE INTEGRATION OF COMPONENTS OF FIRE TECHNOLOGY

  • Marchant, Eric W.
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.11-18
    • /
    • 1997
  • Fire safety systems in large buildings are likely to be complex and may be designed independently of other systems. This means that the interactions and interfaces between the fire safety systems and between the environmental control systems and the fire safety systems may not be carried out properly. Many large, recent buildings have many technological component systems that are used for the control of the environment within the building. Because of the "special" nature of the fire safety systems there is little consideration is given to the possibility systems with a dual function. However, many of the functions of fire safety systems are extensions of systems that provide the day to day control over the internal environment. The present world-wide trend towards the establishment of performance codes, and regulations, will enable the functional design of all systems and thereby allow closer integration of the "ordinary" and "special" systems. Some aspects of the functional and performance characteristics of systems in buildings are introduced and discussed. Special reference is made to the contributions of the systems to the minimisation of fire damage.e minimisation of fire damage.

  • PDF

Analysis of the Impact of Fire and Explosion Accidents due to LNG Leaks in the LNG Re-gasification Process (LNG 재기화 공정에서 LNG 누출에 따른 화재 및 폭발사고의 피해영향 분석)

  • Lee, Yoon-Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.6
    • /
    • pp.825-833
    • /
    • 2018
  • In this study, one calculated the range of damage to the combustion characteristics according to the composition of LNG and the size of leaking holes, and analyzed the damage effect in case of leakage accidents caused by pipe damage in the re-gasification process for the LNG supply system. In order to confirm the combustion characteristics according to LNG composition, there was no significant difference in the result of risk analysis by LNG-producing areas. However, the higher the methane content of the components, the lower the risk of flash fire, hazardous areas of overpressure due to explosion, and thermal radiation damage caused by jet fire. In addition, one investigated the effect of leakage, holes, and ruptures on the risk range and explosions according to the size of the pipe-leakage hole. Also, the influence of overpressure and the range of damage from radiant heat could be predicted. One confirmed the effect of LNG composition and pipe-leakage size on fire and explosion.

Regional Characteristics Model to Explain Fire Damage Elements : Hypotheses and Verification (지역 유형별 화재 피해 특성변수 모델: 가설과 검증)

  • Kang, Byungki;Chang, Eunmi;Choi, Kapyong
    • Journal of the Korean association of regional geographers
    • /
    • v.21 no.2
    • /
    • pp.379-393
    • /
    • 2015
  • The fire damage has been increased as the frequency of fire incidence decreases with increasing in death and economic loss. Local governments are dependent on the activities of fire-fighters with crude preparedness and prevention for fire incidence. Most of researches on fire safety have focused on descriptive statistics which show general trends in fire incidence and condition. Here we tried to make a mutual causal model for fire damage, to make three big hypotheses with laying three small hypotheses under each big hypothesis. Five years statistics from public domains in the form of hardcopy or softcopy were collected and fifteen independent variables were selected to explain the number of death, the number of fire incidence and the amount of economic loss from fire incidence. The significances of statistics are different among the regional characteristics. The hypotheses were partially rejected and the meanings of rejected factors will refresh the tentative prejudice. It is necessary to revise the principle that the number of population and size of area are regarded as the most important criteria to allocate resources for fire control and to have the criteria flexible with results of our research such as the number of the weak to fire disaster.

  • PDF