• 제목/요약/키워드: Fire brigade

검색결과 33건 처리시간 0.029초

화학사고 초기대응 소방대 보호를 위한 독성농도(T-LOC) 끝점거리 연구 (Toxic Concentration(T-LOC) Endpoint Distance Study for Fire Brigade Protection in Response to Chemical Accidents)

  • 윤종찬;조철희;원정훈
    • 한국안전학회지
    • /
    • 제38권6호
    • /
    • pp.60-71
    • /
    • 2023
  • The purpose of this study is to propose a quantitative toxicity endpoint distance suitable for the initial response of firefighters by comparing and analyzing the commonly applied toxic level of concern (T-LOC), specifically emergency response planning guidelines (ERPG), acute exposure guideline levels (AEGL), and immediately dangerous to life or health (IDLH). This is to protect the fire brigade, which responds to toxic chemical accidents first during the golden time. Using areal locations of hazardous atmospheres, a damage prediction program, the amount of leakage for both acidic and basic substances, along with the endpoint distance, were analyzed for alternative accident and worst-case accident scenarios. The results showed that the toxicity endpoint distance, serving as a compromise between Level-3 and Level-2 of T-LOC, was longer than ERPG-3 and shorter than ERPG-2 with IDLH, while its values were analyzed in the order of ERPG-2, AEGL-2, IDLH, AEGL-3, and ERPG-3. It is suggested that the application of IDLH in an emergency (red card) and ERPG-2 endpoint distance in a non-emergency (non-red card) can be utilized for the initial response of the fire brigade.

의용소방대의 근무복 개발에 관한 연구 (A Study on the Development of Working Uniform for Volunteer Fire Brigade Members)

  • 석혜정;김인숙;정기수;배주형;권명숙;양민재
    • 대한가정학회지
    • /
    • 제44권7호
    • /
    • pp.63-72
    • /
    • 2006
  • The purpose of this study was to survey the wearing practices and problems in the working uniform for volunteer fire brigade members and then to develop its design with a improved movement adaptability, physical suitability, ease for equipment accommodation, functionality, convenience and fit. Based on the questionnaire, we have made a testing uniform for volunteer fire brigade members first. Through a subjective analysis for functionality and apparence, we suggested a final design. The final design includes the following elements: 1. It was a two-piece style composed of a jumper and trousers with the upper garments pulled out. Raglan sleeves were used to increase arm's movement scope. Pleats and velcro tapes were attached along the base hem of sleeves to prevent heat transmission. 2. Various types of pockets were attached to secure enough space for keeping things. 3. In trousers, spare space was given at the buttock area with rubber string inserted only at selected part of side lines, and knee pads were attached to prevent wearing out.

농·어업용 Vinyl 가설건축물의 화재 예방 및 진압에 관한 연구 (A Study on the Prevention and Extinguishment of Fire in Vinyl Temporary Buildings for Agriculture and Fishery)

  • 이봉우;박경진
    • 한국산업융합학회 논문집
    • /
    • 제26권4_2호
    • /
    • pp.599-603
    • /
    • 2023
  • Analyzed in the NFDS, The average number of fires in vinyl temporary buildings is more than 1,000 in annually. And the number of deaths and injuries was around 30 people in every year. According to the National Fire Agency, There are 142,386 vinyl temporary buildings for Agriculture and Fishery, of which 4,720 are residential vinyl temporary buildings in illegally. Model house is subject to regulation in fire-related law. But, even though it's the same temporary building, Vinyl temporary building is not subject to regulation. For this reason, Vinyl temporary buildings are left in the blind spot of fire safety. Therefore, In this study, We propose that amend of Act on installation and management of firefighting systems, make of temporary fire safety controller, develop and apply of alarm system that is connected to a single-alarm smoke dretector, organize and operate volunteer fire brigade of the crop group to prevent and extinguish the fire.

의용소방대용 근무복 소재의 역학적 특성 및 쾌적성에 관한 연구 (A Study on the Mechanical and Comfort Performances of the Working Uniform for a Volunteer Fire Brigade Member)

  • 권명숙;심현섭;권진
    • 복식
    • /
    • 제57권3호
    • /
    • pp.53-62
    • /
    • 2007
  • The purpose of this study was to investigate mechanical and comfort performances of the material for the improved working uniform for a volunteer fire brigade member, to get basic data for its evaluation and to help its material and design development. The results were as follows; The material of the newly developed working uniform was thinner and lighter than the material of the current used working uniform. It had better breathability, air permeability and heat transmission rate than the current one. It also had superior anti-flammability In all mechanical properties(tensile, bending, shearing, compression and surface properties), it showed better performances than the current one. It elongated and bended easier and more in both warp and weft directions. The elastic recovery and shape stability after elongation were also higher. The recovery and resistance to shearing and the resiliency and recovery after compression were also better than the current one. It was more flexible, softer and smoother in primary hand value, and was more suitable for the material for winter suit which needs softness and fullness in total hand value. The material of the improved working uniform showed lower thermal insulation value and higher evaporative resistance value compared to the material of the currently used working uniform from the sweating thermal manikin test. It was shown that the physical performances and the hand value of the textile material used in the newly developed working uniform for a volunteer fiber brigade member was improved compared to the one used in the currently used working uniform.

근접성이 불리한 대학 기숙사의 학생 의용소방대 도입에 관한 연구 (A Study on Introduction of Student Volunteer Fire Department in Dormitory far from Fire Station)

  • 백두산;이승철
    • 한국화재소방학회논문지
    • /
    • 제29권3호
    • /
    • pp.65-69
    • /
    • 2015
  • 대학 기숙사는 기능이 다양하고 유동인구가 많아 화재발생시 많은 인명피해가 발생할 수 있다. 또한 119 안전센터와 근접성이 불리한 경우 소방대가 골든타임 내에 도착하기 어렵다. 따라서 자체적으로 화재에 대한 대응능력이 필요하다. 본 연구에서는 소방차의 현장 근접성이 불리한 강원도 K대학 기숙사 거주자를 대상으로 화재모의실험을 실시하여 재실자의 피난특성을 살펴본 결과 초기화재대응을 위한 기숙사 관리자의 부족과 피난경로의 부족으로 인하여 피난이 지연되었고, 일부 학생은 화재에 대한 의식이 부족한 것으로 나타났다. 그리고 소방대는 골든타임 내에 기숙사에 도착하지 못했다. 따라서 관리자의 부족과 소방대의 근접성이 불리함으로 발생하는 화재대응 문제를 해결하기 위해 학생의용소방대 도입을 제안했다.

일본 의용소방대 운영실태의 분석 (Analysis of Volunteer Fire Brigade in Japan)

  • 이의평
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 춘계학술논문발표회 논문집
    • /
    • pp.276-281
    • /
    • 2011
  • 일본은 소방제도의 틀이 잘 발달되어 있으면서도 잦은 자연재해 등으로 인해 지역주민에 의한 상부상조의 조직으로서 의용소방대가 발달되어 있다. 특히 화재의 발생이 많지 않거나 사고가 빈번하게 발생하지 않지 않는 지역에서는 의용소방대가 주도적인 역할을 담당하고 있다. 관설소방이 충분히 발달된 지역에서도 지진 등 천재지변의 대응에 대비하여 의용소방대를 육성 발전시키고 있다. 이 논문에서는 일본 의용소방대의 운영실태, 의용소방대 활성화를 위한 소방청의 추진사항 등에 대해 분석한다.

  • PDF

한일 의용소방대 비교 분석 (Comparative Analysis of Volunteer Fire Brigade in Korea and Japan)

  • 이의평
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 추계학술논문발표회 논문집
    • /
    • pp.340-343
    • /
    • 2011
  • 이 논문에서는 한일 의용소방대에 대해 관련법령과 조례, 조직, 보유장비와 시설, 대원확보대책, 의용소방대 존재필요성에 대한 인식 등을 비교하였다. 이 비교분석을 통해 일본은 우리나라보다 관설소방이 잘 발달되어 있음에도 불구하고 의용소방대를 활성화하기 위해 소방청 차원에서도 다양한 정책과 제도를 개발하여 시행하고 있음을 알 수 있고, 관설소방이 잘 발달된 동경(東京)도 서울과 달리 의용소방대를 육성 발전시키고 있음을 알 수 있다.

  • PDF

법규적 측면에서 고찰한 고층 건축물 공사현장 화재안전 확보방안 (A Study on the Improvement of Fire Safety in high-rise Building Construction in Legal aspects)

  • 박찬석;정일균
    • 대한안전경영과학회지
    • /
    • 제17권1호
    • /
    • pp.21-32
    • /
    • 2015
  • High rising of the buildings offers a number of risk factors than ever before with regard to fire prevention. Especially in the construction site of high-rise buildings, people waste golden-time during the evacuation because temporary fire fighting facilities are not installed and transferred to a large fire because of fire suppression failure. In this study, the researcher derives the problems of fire protection in high-rise buildings construction sites and proposed the measures in such the legal aspects as fire building construction code and etc. There are the legal improvements such as orders of construction suspension in the problems of fire safety, appointing fire safety manager, temporary fire protection installation standards, enhancing penalty provisions regarding the use of fire, operating self fire brigade, confirming on-site after completing fire-protection facalities, establishment or strengthening special fire-protection investigations.

Fire hazards in tunnels and underground installations

  • Opstad Kristen
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
    • /
    • pp.27-32
    • /
    • 2003
  • Fire accidents in tunnels and underground installations have resulted in significant loss in terms of life and costs. Several large research projects are launched in Europe to find cost effective ways to upgrade and make such installation more robust against accidents from fires and explosions. For one single tunnel, severe fire accidents are rare and operators and users will have very limit experience, when they do occur. There is a trend to solve the problem with high tech instrumentation and monitoring techniques and to rely on the fire brigade to play a major role in the rescue operation. These precautionary measures are very difficult to validate for the severe fires. For protection against the most critical fires, the safety has to be considered in the design of the tunnel and the technical installation validated so that it operates as indented.

  • PDF

전통사찰의 현장실태분석을 통한 소방안전대책에 관한 연구 - 서울특별시 은평구를 중심으로 - (The Study on the Fire Safety Plans by a Field the Actual Condition Analysis of Traditional Temples - With Special Reference to Eunpyeonggu Seoul -)

  • 송윤석;현성호;김완섭
    • 한국화재소방학회논문지
    • /
    • 제22권5호
    • /
    • pp.137-147
    • /
    • 2008
  • 본 연구에서는 전통목조건축물 중에서 전통사찰을 대상으로 소방안전 관련규정과 주요 화재원인 및 사례 등을 검토하여 화재취약성을 분석하였고, 서울특별시 은평구에 있는 문화재를 보유한 전통사찰의 3개소에 대한 현장조사를 통하여 지리적 여건, 소방대의 출동경로 현장 도착 소요시간, 소방시설, 방화관리 및 보안시스템, 화재취약요인 등에 대한 실태를 분석하여 전통사찰의 소방안전대책에 대해서 제시하였다.