• Title/Summary/Keyword: Fire accident

Search Result 703, Processing Time 0.023 seconds

Analysis and Risk Prediction of Electrical Accidents Due to Climate Change (기후환경 변화에 따른 전기재해 위험도 분석)

  • Kim, Wan-Seok;Kim, Young-Hun;Kim, Jaehyuck;Oh, Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.603-610
    • /
    • 2018
  • The development of industry and the increase in the use of fossil fuels have accelerated the process of global warming and climate change, resulting in more frequent and intense natural disasters than ever before. Since electricity facilities are often installed outdoors, they are heavily influenced by natural disasters and the number of related accidents is increasing. In this paper, we analyzed the statistical status of domestic electrical fires, electric shock accidents, and electrical equipment accidents and hence analyzed the risk associated with climate change. Through the analysis of the electrical accidental data in connection with the various regional (metropolitan) climatic conditions (temperature, humidity), the risk rating and charts for each region and each equipment were produced. Based on this analysis, a basic electric risk prediction model is presented and a method of displaying an electric hazard prediction map for each region and each type of electric facilities through a website or smart phone app was developed using the proposed analysis data. In addition, efforts should be made to increase the durability of the electrical equipment and improve the resistance standards to prevent future disasters.

A Semantic Service Discovery System for Smart-Cities (스마트시티를 위한 시맨틱 서비스 디스커버리 시스템)

  • Yun, Chang Ho;Park, Jong Won;Jung, Hae Sun;Lee, Yong Woo
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.6 no.6
    • /
    • pp.281-288
    • /
    • 2017
  • In Smart-cities, various types of integrated services must be linked to provide services to applications. Therefore, flexibility must be ensured between services so that various services can be efficiently provided. In order to secure the flexibility among services, it is very important to have a function to dynamically discover and invoke a desired service by searching for a semantic service by reflecting a recognized context through real-time context-aware in smart-cities. To date, quite a number of semantic service discovery techniques have been developed. However, they have not been verified as suitable for use in the smart-city domain. In this study, we tried to verify the existing ones to use a suitable one. We tested most of existing semantic service discovery techniques, but we found that none of them is suitable to our research. Therefore, we developed our own semantic service discovery technique. This paper introduces our work and presents the performance evaluation results that demonstrate that our developed works well and show good performance. For the performance evaluation, the experimental system was actually constructed and the real performance was measured. In the experiment, we implemented the semantic service discovery scenario that dynamically searches and calls the services needed to provide fire accident management services in smart cities.

Development of Silm Type ELCB For Airport Distribution Panel through Increased short Circuit Capacity (단락용량 증대를 통한 슬림형 공항 분전반용 누전 차단기 개발)

  • Joo, Nam-Kyu;Lee, Jong-Myong;Kim, Nam-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.2
    • /
    • pp.360-366
    • /
    • 2012
  • In the power distribution panel installed in airport or industrial facilities, MCCB has been used for main switch and ELCB for branch switch to perform human body and leakage-inducing fire protection as well as overcurrent and short circuit protection. Especially for the airport panel, increase in accident protection is needed for stable power supply due to rapid modernization with fast-growing users, higer capacity and diversification of equipment, the increase of power capacity and the breaker made slim is a main issue for now because the issue for installation space is standing out by making panel with two-row arrangement connection method, etc. due to a many use of branch ELCBs. In this thesis, we designed arc extinguishing mechanism, considered movement direction change of contact in mechanism design. Also, we designed the breaker to work stably in case of miniaturization of leakage detection circuit and reverse connection. We conducted short circuit test to verify its function and developed the breaker that can be improved protection against accidental current with slim size operating leakage function when reverse connection to help solve the problem in using space that is increasing in the airport distribution panel.

Basic Studies on Banwoldang(Half-moon shaped Pond) at the Traditional Chinese Villages (중국 전통마을의 반월당(半月塘)에 관한 기초연구)

  • Wang, Qiao;Sim, Woo-Kyung
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.32 no.3
    • /
    • pp.121-129
    • /
    • 2014
  • This study was carried out to research the locations and comprehensive functions of Chinese unique Banwoldang(half-moon shaped pond) appeared at the traditional Chinese villages. Based on the research, the time of Banwoldang being introduced into Chinese traditional culture could date back to Yuan Dynasty and villages that have Banwoldang mainly distributed in the south of the Yangtze River of China where wealthy and high class have lived. Bamwoldangs were mostly built at the front of the village clan halls for the prosperity of the whole clan, The main reason of Banwoldang construction was to complete Feng Shui functions and its goal from the point of Feng Shui in Chinese ancient villages was replenishing the power of location, including increasing the probability of passing the imperial examination for villagers, multiplying riches, minimizing the fire accident and perfecting the geomantic pattern 'leaning against the hill and facing the water(背山臨水)' of villages. Other functions of Banwoldang were found as the place for the community meeting, fish farming and protection of village from enemy. In this research, the reasons of Banwoldang location and values of its various functions were found. But Banwoldang is disappearing rapidly at the Chinese modern villages because there is no interest in traditional culture. Banwoldang is one of unique elements of Chinese culture that must be preserved, so its meaning and value should be lasted well as the Chinese traditional cultures.

A Study on the Introduction Direction of Private Investigation Law (민간조사업법의 도입방향에 관한 연구)

  • Lee, Seung-Chal
    • Korean Security Journal
    • /
    • no.17
    • /
    • pp.255-276
    • /
    • 2008
  • The important items, which should be considered in Private Investigation Law, can include subjects, licenses, the scope of business, qualifying examinations, and supervisory and penal provisions. The subjects of Private Investigation Law should be permitted to be both natural persons and juridical persons in terms of providing various services, but should be permitted to be juridical persons and should be administered on a license system, even in order to ensure public interests. Concretely, the introduction scope of Private Investigation Law can be regulated to include the followings: that is, investigating the whereabouts identification of runaways and missing children, investigating the personal identification, habit, way of action, motivation, whereabouts identification, real child confirmation, association, transaction, reputation, and personality of specific persons or specific groups, investigating the whereabouts identification of missing persons, owners of government-vested properties or renounced properties, investigating the whereabouts of lost properties or stolen properties, investigating the causes of fire, character defamation, slander, damage, accident, physical disability, infringement on real estate or movable property, and investigating all sorts of accidents including traffic accidents, insurance accidents, and medical malpractices. In the qualifying examination, examinees' age should be restricted to be over age 25. The person, who is exempted from its primary examination, should be restricted to be the person, who has the career of over 20 years in related fields, in consideration of its equity with other certificates of qualification. In the supervisory institution, as the policy institution is the supervisory institution in many countries including France (the police) and Japan (public security committee), so the National Policy Agency should be the supervisory institution in consideration of management aspects. In the penal regulations, especially, we should clarify the management of personal information (personal information protection, personal information management), and so should prevent the infringement of people's basic rights, and then should ensure the public interest.

  • PDF

A Study on the Actuality of School Safety and the Development of Safety Manual (학교안전교육의 실태분석과 안전교육매뉴얼 개발에 관한 연구)

  • Kim, Tae-Hwan
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.5 no.3 s.18
    • /
    • pp.83-88
    • /
    • 2005
  • It is necessary to hold the school safety manual because recently, the safety-related accidents occur frequently in schools. Accidents can occur inside of schools as well as out of schools, and they can be classified with human accidents, traffic accidents, fire accidents, and explosion accidents. Safety-related accidents occurring in the school are dangerous because nobody can predict them. Illegally infringing violence, targeting unspecified and a lot of people, informs the parents and persons concerned to education of danger. School safety manual, never precedented before, describes epoch-making educational methods for students' safety. It describes safety security such as refuging ways at an emergency, the way to recognize danger for elevated safety based on prevention education, the use and practice of checklist for related facilities, and the implements and facilities for school personnels and students. So, the school safety manual is an important guidance for safety education at the level of prevention from various accidents which occur inside the school as well as out of the school. It presents a variety of prompt response after an accident. At the same time, it checks facilities and dangerous factors in schools and facilities for safety, and analyzes special factors based on them. So it will present the status of safety management of existing facilities and implements, the installment of new facilities and implements, and the way to secure safety for use.

An Empirical Study on Evaluation of Performance Shaping Factors on AHP (AHP 기법을 이용한 수행영향인자 평가에 관한 연구)

  • Jung, Kyung-Hee;Byun, Seong-Nam;Kim, Jung-Ho;Heo, Eun-Mee;Park, Hong-Joon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.1
    • /
    • pp.99-108
    • /
    • 2011
  • Almost all companies have paid much attention to the safety management ranging from maintenance to operation even at the stage of designing in order to prevent accidents, but fatal accidents continue to increase throughout the world. In particular, it is essential to systematically prevent such fatal accidents as fire, explosion or leakage of toxic gas at factories in order to not only protect the workers and neighbors but also prevent economic losses and environmental pollution. Though it is well known that accident probability is very low in NPP(Nuclear Power Plants), the reason why many researches are still being performed about the accidents is the results may be so severe. HRA is the main process to make preparation for possibility of human error in designing of the NPP. But those techniques have some problems and limitation as follows; the evaluation sensitivity of those techniques are out of date. And the evaluation of human error is not coupled with the design process. Additionally, the scope of the human error which has to be included in reliability assessment should be expanded. This work focuses on the coincidence of human error and mechanical failure for some important performance shaping factors to propose a method for improving safety effectively of the process industries. In order to apply in these purposes into the thesis, I found 63 critical Performance Shaping Factors of the eight dimensions throughout studies that I executed earlier. In this study, various analysis of opinion of specialists(Personal Factors, Training, Knowledge or Experience, Procedures and Documentation, Information, Communications, HMI, Workplace Design, Quality of Environment, Team Factors) and the guideline for construction of PSF were accomplished. The selected method was AHP which simplifies objective conclusions by maintaining consistency. This research focused on the implementation process of PSF to evaluate the process of PSF at each phase. As a result, we propose an evaluation model of PSF as a tool to find critical problem at each phase and improve on how to resolve the problems found at each phase. This evaluation model makes it possible to extraction of PSF succesfully by presenting the basis of assessment which will be used by enterprises to minimize the trial and error of construction process of PSF.

Effects of the Safety and Health Management System on the Performance of the Enterprise: Focus on the Electric Power Corporation (안전보건경영시스템의 운영방침이 기업성과에 미치는 영향: 전기공사업을 중심으로)

  • Kim, Sang-Sig;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.1
    • /
    • pp.135-145
    • /
    • 2020
  • This research is mainly aimed at finding out about the effects of the safety and health management system on corporate performance through systematic operation by efficiently allocating material and human resources within the company by participating all employees and stakeholders in order to prevent and maintain industrial accidents and the optimal working environment, and how to maintain and activate the safety and health management system at the center of electric contractors.The analysis results are as follows. First, management, organizational management and resource preparation will have a positive impact on the management capability of the electric power corporation. It was assessed that the more well-transmitted and understood within the organization, the better the construction plan, the better the equipment management status, the more positively the management capability of electric works was to be achieved. Second, management, organizational management and resource preparation will have a positive impact on corporate management performance.This seems to have a positive effect on a company's business performance when the standards of OHSAS are met with construction plan and construction equipment management are high as related information such as industrial safety and health laws are strengthened and companies' safety and health activities, advanced safety and culture are released to facilitate organizational management.Third, the management ability of the electric power corporation will have a mediated effect on the effect of management, organization management and resource preparation on the performance of the enterprise. This means that the direct effect of the independent variable management organization on corporate management performance is .401 The indirect effect is .168.658 shows that the direct effect of resource preparation on corporate management performance is .423, the indirect effect is .178 and the total effect.It was analyzed at 643.

Emergency Care Conditions where the Nurse is posted in the 119 Relief Squad (119구급대의 간호사 배치여부에 따른 응급처치 실태)

  • Kim, Young-Im;Jung, Hye-Sun;Lee, Chang-Hyun;Kim, Gum-Sook;Park, Jung-Young
    • Research in Community and Public Health Nursing
    • /
    • v.11 no.2
    • /
    • pp.411-422
    • /
    • 2000
  • The purpose of this study is to identify the difference of emergency care conditions where the nurse is posted in the 119 relief squard or not. The data composed a total of 777 cases of emergency activity of one police stand in Seoul during March, June. September and December in 1998. The results of this study were as follows: 1. The age of the subjects was 20-60 age 54.3%, over 60 age 35.4% with an average age of 50.2. Among them men were 55.0%, the unemployed were 60.8%. The place of the occurrence of an accident was the house, 49.7% and the cause as illness was 59.6%. 2. The main symtom was pain the 36.2% the main consciousness state was alert 76.9%: The state of the patients as chronic was 59.6%. 3. The consulting hospital of the 119 relief squad as a third medical center was 79.9%. The distance to the medical center as less than 5 km was 77.2%, and an average transfer distance was 5.38 km. The cases of doctor guided emergency care was 0.9%, the cases that had posted nurses in 119 relief squads was 48.6%. 4. The case of the best emergency care operation was difficulty in breathing, 62.1% and the second was unconsciousness, 46.1 %. The more serious the consciousness state, the higher the rate of emergency care operation. There wasn't any difference in emergency care operation concerning transfer distance. 5. The cases that had the posted nurses was 19.1%, the cases of no nurse was 11.7% among the cases of emergency care operation during transfering; the cases that had posted nurses had the higher emergency care operation. (p<0.05). Airway maintenance was 14.8% in cases that had the posted nurses, while in the cases of no nurse, 10.9%; and oxygen inspiration was 16.0% in cases that had the posted nurses while in the cases of no nurse 7.6% (p<0.01); spinal fixation was 6.6% in cases that had the posted nurses while in the cases of no nurse 4.6%(p<0.05). With these results, we can conclude that the cases that had the posted nurse showed higher emergency care operation.

  • PDF

Design and Verification of Housing and Memory Board for Downsizing for Crash Protected Memory Module (충돌보호메모리모듈의 소형화를 위한 하우징 및 메모리 보드 설계와 검증)

  • Kim, Jun-Hyoung;Kim, Jung-Pil;Kim, Jeong-Yeol;Kim, Tae-Won
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.1
    • /
    • pp.81-88
    • /
    • 2020
  • Flight data recorder is a equipment that records data required for investigation of aircraft accidents and should be developed in compliance with the ED-112A standard. Unlike general data storage device, flight data recorder must be able to recover data after an aircraft accident, requiring a housing and a memory board to protect data in extreme environments. To attain this performance, we designed a housing that can withstand the test by analyzing the physical environment of the impact, shear/tensile, penetration resistance and static crush test of the crash survival test and minimized the size and weight compared to the existing one in consideration of the installation of the aircraft in this paper. Insulation material and thermal block material were applied to endure high and low temperature fire so that the internal temperature does not rise above 150℃ even in 260℃, 10 hour environment. In addition, the memory board is designed to minimize the size and we devise a hoping programming method to prevent continuous data loss of more than 16 seconds. Through this, Crash protected memory module that satisfies ED-112A was completed.