• Title/Summary/Keyword: Fire Training

Search Result 384, Processing Time 0.028 seconds

Analysis of evacuation for fishery training ship HANMIR using SEA-Pro (SEA-Pro를 이용한 어선실습선 한미르호의 피난 분석)

  • KIM, Won-Ouk;KIM, Seok-Jae
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.57 no.3
    • /
    • pp.228-235
    • /
    • 2021
  • Marine accidents caused by ships are very diverse, such as collision, sinking, stranding, grounding and fire. In particular, persons on passenger ship are unspecified and not trained, so it makes evacuation harder. For this reason, an evacuation plan that considers diverse situation in ship is needed. Effective evacuation planning requires training in consideration of various evacuation situations. In this paper, we investigated the time elapsed on evacuation in various situations from "HANMIR," the fishery training ship of the Korean Institute of Maritime and Fisheries Technology, using a Ship Evacuation Analysis Program (SEA-Pro) which is introduced to the society. We assumed a situation that has not only inconveniences for real training but also the possibilities of happening. Not all trainees are resting in their cabin, so we assumed positions such as they are in the bridge or engine room and applied fire and flooding situations. We assumed that the time for alerting the situation would be short, so we applied only elapsed time of movement. Those analyses could be helpful in three ways. The first is predicting the consequence of possible accidents. There are some conditions that can be appliable to this model, such as the decreased area of sight in those situations. The second is concluding the optimal limit of carriage and placement of safety instruments on building a new ship. The third is to be a base data for ships to make a new effective evacuation plan based on these analyses.

A Study on the Problem and Improvement of the Fire Detector Test in the Field (화재감지기 현장점검의 문제점 및 개선방안에 관한 연구)

  • Ok, Kyung-Jea;Cha, Ha-Na;Kim, Shi-Kuk;Lee, Chun-Ha
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.180-184
    • /
    • 2008
  • Fire prevention strategies should be aimed at the prevention of structured fire since average annual rates of structured fire have been increased due to economic growth resulted in increasing high rise buildings and multipurpose occupancies over the past ten years. Hence, this study mainly focused on the improve method and problems in the field test of fire detector in compliances with experimental consideration. And it leads us to the flowing conclusions : Firstly, it is necessary to formulate a safety standards on field test. Nowadays, the test enforced in many ways without formulated standard. Therefore it is necessary to be complete the arrangements standardized and how to do the test with formulated safety standards. Second, it is necessary to establish the regal guidance with regard to inspection equipment, ie density, component and temperature of test equipment should be considered. Also the equipment is need to be standardized and improved. Third, fire inspector's competency in their practice should be enhanced. The problems arising from the lack of knowledge and competence regarding inspection could be settled by providing professional education to ensure proficiency in their practice. Specialized training, as has been noted, should be offered in accordance with occupancy type, scale and fire protection system in the fire facilities.

  • PDF

Identifying Hazard of Fire Accidents in Domestic Manufacturing Industry Using Data Analytics (국내 제조업 화재사고 데이터 분석을 통한 복합 유해·위험요인 확인)

  • Kyung Min Kim;Yongyoon Suh;Jong Bin Lee;Seong Rok Chang
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.4
    • /
    • pp.23-31
    • /
    • 2023
  • Revising the Occupational Safety and Health Act led to enacting and revising related laws and systems, such as placing fire observers in hot workplaces. However, the operating standards in such cases are still ambiguous. Although fire accidents occur through multiple and multi-step factors, the hazards of fire accidents have been identified in this study as individual rather than interrelated factors. The aim has been to identify multiple factors of accidents, outlining fire and explosion accidents that recently occurred in the domestic manufacturing industry. First, major keywords were extracted through text mining. Then representative accident types were derived by combining the main keywords through the co-word network analysis to identify the hazards and their relationships. The representative fire accidents were identified as six types, and their major hazards were then addressed for improving safety measures using the identification of hazards in the "Risk Assessment" tool. It is found that various safety measures, such as professional fire observers' training and clear placement standards, are needed. This study will provide useful basic data for revising practical laws and guidelines for fire accident prevention, system supplementation, safety policy establishment, and future related research.

A Study on the Policy Tasks for the Development of National Fire Service - Redesigning Institutional and Organizational Improvement for the Establishment of the National Fire Service Agency - (한국소방발전을 위한 정책과제 연구 - 소방청 신설에 대응하는 제도·조직개선 구상 -)

  • Choi, Byoung-Hahk;Kim, Hak-Soo
    • The Korean Journal of Emergency Medical Services
    • /
    • v.6 no.1
    • /
    • pp.185-197
    • /
    • 2002
  • Today, the basic problem of functional safe management of Korean Disaster Control system was separately administrated 33 acts that are relating to safe management in 13 ministries. Because of the facts that the fire service is not provided practically, the control system and risk management for safe administration are not operated, the information can not be shared with each other, and the various laws have the lacks of linkage, the National Safe System was appeared unsteady. The roles and functions of fire service have started with restriction to operate structurally and institutionally, which operational structure of fire service is becoming weak. As a result, the federal and local fire organizations have not reached yet to the institutionalization and the local fire service agencies have bias with the task regarding the fire service because of the relation between organizational structure and the local fire agency. With the enforcement of the federal and local fire system, professionality and autonomy for making policy, and dealing with changes of fire service positively, the national fire service on the policy performance can be established. Promotion of research and development and education training to strengthen innovation in technology and competition in fire industry will contribute to the firmly establishment of control system to prevent from fire, flood, terror and national disaster. This article proposed that (a) the established law and administration, agency are required efforts to effectively operate fire service system; (b) the national fire service agency, national college of fire, national institute of science fire, and national fire service hospital should be early established to make firmly policy to operate effectively and practically. These kinds of innovational acts are known the best ways of operating solid policy of national fire service system.

  • PDF

A Study on Learning Model for Re-education and Valuation of EMT (구급대원 재교육 및 평가를 위한 학습모형 연구)

  • Kim, Sun-Bae;Ann, Dong-Yeal;Lee, Nam-Soo;Choi, Zoo-Ill;Oh, Kyung-Ghn;Park, Inn-Soo;Park, Hee-Jin
    • The Korean Journal of Emergency Medical Services
    • /
    • v.9 no.2
    • /
    • pp.183-206
    • /
    • 2005
  • Nowadays, the whole world is putting in the knowledge information society by the internet which is connecting the global network. The internet enable us to see the life of the other people in real time. Most of health care professional obtain and update their new knowledge and skills through continuing education. EMTs who works five or ten shifts per day are not easy to attend continuing education session usually offered during their off-times. One of solutions to this problem would be to develop a education program which does not limit time and place. There has been increasing interest in the use of computers in medical education, but all designated facilities and teachers have no sufficient preparations for the education and training of EMT. There has been less attention to the rationale for the use and selection of applications. This article discusses an approach to the selection of medical informatics applications for the undergraduate medical curriculum. The aim of this study is to develop and evaluate a web-based continuing education program, to help EMT improve their knowledge of transfusion therapy and medical law, and to enhance their ability to contribute to the quality of patient care. The program generally was well received by EMTs. The program is a useful adjunct to the existing continuing education program. It also could be used in EMT student education and other health sciences.

  • PDF

The Development of a Ship Firefighting Drill Simulator (선박소화훈련 시뮬레이터 개발에 관한 연구)

  • Kim, Won-Ouk;Kim, Dae-Hee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.5
    • /
    • pp.410-416
    • /
    • 2016
  • After the Sewol Ferry accident, the importance of maritime safety has been emphasized in Korea. In particular, educational and experience training are not only being conducted for maritime personnel but also in schools and at maritime-related organizations in order to broadly instill maritime safety awareness. Based on SOLAS regulations, safety education for sailors conducted every 10 days passenger boats, and fire-fighting drills and abandon-ship training should be conducted once a month on merchant ships. After the Sewol Ferry accident, the maximum number of trainees was reduced from 40 to 20 in order to improve the effectiveness of these training sessions by requiring all trainees to participate in the actual training. The current training process consists of two steps: textbook-based theoretical training and actual practice. Current training environment provides limited capability from human and facility recourses which limit the numbers of trainee participated and system operation time. By introducing the simulation training, it will improve the trainee skill and performance prior to the on-site training and allow the more effective and rapid progress on actual practice. Therefore, it will be proposed the three-step training method in order to improve the effectiveness on fire-fighting drill in Maritime Safety Education on this study. This study suggests a three step training method that would increase the efficiency of maritime safety education. An image-training step to enhance individual task awareness and equipment usage via simulation techniques after theoretical training has been added. To implement this simulation, a virtual training session will be conducted before actual training, based on knowledge obtained from theoretical training, which is expected to increase the speed with which trainees can adapt during the practical training session. In addition, due to the characteristics of the simulation, repeated training is possible for reaction drills in emergency circumstances and other various scenarios that are difficult to replicate in actual training. The efficiency of training is expected to improve because trainees will have practiced before practical training takes place, which will decrease the time needed for practical training and increase the number of training sessions that can be executed, increasing the efficiency of training overall. This study considers development methods for fire-fighting drill simulations using virtual reality techniques.

A Study on Safety Training Program at Elementary School : with an Emphasis on Curriculum Changes (초등학교 안전교육 실태와 발전방향에 대한 연구)

  • Suk, Hye-Min;Park, Chan-Seok;Yoon, Myong-O
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.151-160
    • /
    • 2013
  • Recently, children's deaths are found to be mostly caused by various accidents in Korea. But it is in reality that the safety training are very roughly conducted, and even contemporarily appropriate training materials are not sufficiently furnished contrary to the increasing significance of the safety training to reduce the children's accidental risks. This study is to compare and analyze the safety training courses of domestic and overseas elementary schools and various safety training materials. This study is purposed ultimately to reduce the accidental risks of elementary school students by suggesting the future development direction. It is concluded in this study that more appropriate safety training courses and materials should be provided to train the students to habituate their safe behaviors with a view to protect the elementary school students against the accidents. In addition, the safety training should be conducted consistently by reflecting the students' characters, and the pertinent training materials should be developed for the students' spontaneous learning and for more practical preventive training.

A Study on the Actual Education Condition and Improvement Program of Fire Investigator (화재조사자의 교육실태 및 개선방안에 관한 연구)

  • Choi, D.M.;Park, C.W.;In, S.J.;Lee, C.W.
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.72-80
    • /
    • 2007
  • In order to breed fire investigators, can scientifically find out the truth of fire causes, the development of special and systematic education programs and the repetitive retraining are the most important factor. In this study, the working problems of curriculum for fire investigation course were analyzed through the survey. The curriculum and management status of domestic and foreign professional fire investigation education authority were compared and analyzed. And we suggested that the possible solutions to the problem, which can affect on the education effects, curriculums, training methods, selective methods, and effective applying method.

A Study on the Safety and Health Consciousness for the Working Environment of Fire Fighter (소방공무원 근무환경에 대한 안전보건 의식 연구)

  • Lee, Jong-Ho;Kim, Yo-Han
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.1
    • /
    • pp.137-143
    • /
    • 2015
  • Fire fighter are exposed to the situations which are hard to predict due to continuous and accidental changes which hinder their fire fighting activity. As these threats of safety accident act as fear factors, they are doing insecure fire fighting activities. Therefore, as unclear and abnormal risks of working environment such as the riskiness of expansion of disaster, instability, obstacles of activities, abnormality, urgency, etc. increase, safety accidents are caused. This study analyzes the actual condition of safety and health and awareness of fire fighter who are exposed safety accidents during their fire fighting activities and utilize such result as the basis data to secure safety of fire fighter, keep efficient safety control and prevent accidents. The results of analysis are as follows. As rescue works among all fire-fighting works shows the highest emotional stabilization and the highest post-traumatic stress disorder is shown in fire sergeant level positions, and fire fighters whose working period is 10-15 years, reinforcing safety training to long-term workers is necessary. As the result of survey regarding safety awareness, the highest awareness level was shown in fire sergeant level positions, and fire fighters whose working period is over 20 years, and when it comes to operation of fire fighting equipments, fire-fighting workers and workers having 1-4 years of working period showed high safety awareness. The more serious injury in a fire fighter experienced as the first injury after working as a fire-fighter, the more cause-and-effect relationship was shown between personal physical condition and work, and it is shown as obstacles of fire fighting activities and affects to post-traumatic stress disorder. Moreover, as after-work off duty activities also affect to official disaster, systematic improvement of working environment is required. Occupational medical work compatibility evaluation considering the distinct characteristics of works to secure fire-fighter' health care together with fire-fighting capability is shown to be necessary.

Analysis of the Operation of Fire Observers in the Domestic Manufacturing Industry - Focusing on the Revised Occupational Safety and Health Act (국내 제조업 화재감시자 운영 실태 분석 - 개정 산업안전보건법 중심)

  • Kyung Min Kim;Yongyoon Suh;Jong Bin Lee;Seong Rok Chang
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.3
    • /
    • pp.77-84
    • /
    • 2023
  • Welding and cutting, which are representative tasks in handling firearms at industrial sites, are the basis for production and maintenance processes across all industries. They are also essential in the root industry. Specifically, they are widely used in the manufacturing industry, including equipment industries such as shipbuilding, automobiles, and chemicals, and subsequent maintenance work and general facility repair. However, such hot work carries a high fire risk owing to sparks scattering and inadequate management, resulting in a high occurrence of accidents. In response, the government and relevant organizations have recently revised the Occupational Safety and Health Act to prevent accidents during hot work. These revisions impose more stringent regulations than before, which are expected to help prevent actual fire accidents. However, whether the fire observer system, which is the core element of the revision, would be practically applied and maintained is unclear. Therefore, this study compared the fire observer system in the revised Occupational Safety and Health Act with those in the laws and systems of developed countries, conducted interviews with safety and health experts to assess the suitability of the new system for fire observer operations, and improvement plans were derived accordingly. Therefore, the laws and systems of developed countries grant more authority to fire observers compared with those of Korea. Moreover, professional training in handling emergency is required. Interviews with safety and health experts revealed that regardless of company size, the same operating standards were applied, and standards for deploying fire observers in various locations were unclear. Furthermore, there was a lack of professional education and training, and the role and authority of fire observers were limited. These findings revealed a problem in this sector. The results of this study are expected to serve as basic data for establishing a practical system for placing fire observers and supplementing laws, guidelines, and systems for preventing fire accidents.