• Title/Summary/Keyword: Fire Sprinkler System

Search Result 116, Processing Time 0.02 seconds

Improvement Proposal for the Fire Suppression Systems of Open Parking Lots (개방형주차장의 소방설비 개선 제안)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.1-8
    • /
    • 2016
  • In cars, the amount of combustibles, such as plastics, textiles, etc., have increased dramatically to improve the fuel efficiency of cars by reducing the gross vehicle weight according to the increases in an oil price and to reduce environmental problems. One or two cars were involved in a parking lot fire prior to the mid-2000 s. On the other hand, there were many parking lot fires where the entire car was destroyed due to increasing the use of plastics. In this study, the quantity of combustibles in a car was 316.2 kg over a total weight 1935 kg. This is 16.34% of total weight and 10 times greater than that three decades earlier. When a sprinkler is installed as a parking lot fire protection system as a substitute for water spray, the water discharge of the sprinkler must maintain the original density of water spray, $20lpm/m^2$. In addition, the use of a hose reel $CO_2$ system at pilotis parking lots must be prohibited because the hose reel $CO_2$ system has no adaptability for a car fire. Instead, this study proposes foam, dry powder, loaded stream systems be used in parking lot fire suppression systems.

Performance Comparison of Thermal Imagers with Uncooled and Cooled Detectors For Fire Fighting Application (비냉각형 적외선 센서를 이용한 열상시스템과 냉각형 적외선 센서를 이용한 열상시스템의 화재 진압 시 성능 비교)

  • Kim, Byung-Hyuk;Jung, Han;Kim, Young-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.2
    • /
    • pp.128-132
    • /
    • 2007
  • Thermal Imaging systems are reported to be crucial for fire fighting and beginning to be used by fire fighters. The performance of thermal imaging system is determined by both the radiation of infrared from the target and the attenuation of infrared signal in the optical path by the absorption, scattering, diffraction and reflection. In the scene of fire, water drops with various sizes such as vaporized water, wafer mist from sprinkler, and wafer to suppress the fire reside with various gas generated by burning. To measure the transmission of infrared radiation in the scene of fire, fire simulating system and thermal imagers with cooled detector which detects $3{\sim}5{\mu}m$ infrared and uncooled detector fabricated by the MEMS technology which detects $8{\sim}12{\mu}m$ infrared. are made. With thermal imagers and Ire simulating system, the change of thermal image with respect to the change of visibility controlled with the burned fas was measured. It was found that the transmission of infrared was not reduced by the burned gas, which could be explained by the long wavelength of infrared ray compared with visible ray. However, the transmission of infrared ray was largely reduced by the combination of burned gas and water mist supplied by sprinkler. This is contrary to the results of calculated transmission through the pure water mist and shows that the transmission of infrared ray is mostly affected by the compounds of water mist and burned gas. In this case, it was found that the uncooled detector which detects $8{\sim}12{\mu}m$ infrared ray is better than cooled detector which detects $3{\sim}5{\mu}m$ infrared ray for fire fighting.

Fire Experiment for a Water Curtain Nozzle in a Double Glazed Curtain Wall System (유리커튼월 수막시스템 분무헤드의 화재 실험 연구)

  • Kim, Sung-Won;Nam, Jiwoo;Cho, Seongwook;Ryou, Hong-Sun;Nam, Jun-Seok;Kim, Dong-Joon
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.31-40
    • /
    • 2016
  • Recently, a curtain wall system was applied to skyscrapers to prevent fire spreading along the vertical direction due to stack effect and outside air flow when a fire breaks out in skyscraper. Conventional sprinklers cannot prevent the spread of fire to the upstairs areas, which increases the loss of life and property. In this study, a water curtain nozzle that creates wider water coverage on the surface of glass and can prevent the spread of fire to the upstairs areas was developed. The spray pattern of the water curtain nozzle was compared with that of a sprinkler to determine performance of the water curtain nozzle. A fire experiment was constructed on the second floor to verify performance of the water curtain nozzle in preventing the spread of fire to the upstairs areas. The fire and watering experiment proved that the water curtain nozzle prevented more effectively the spread of fire than the conventional sprinkler. The position of first crack and critical temperature of fracture were also analyzed using numerical analysis.

Performance Tests of Fire Control Using Water Mist in a Coach (미세 물분무를 이용한 객차내의 화재제어 성능시험)

  • Kim, D.H.;Park, W.H.;Jang, J.Y.;Lee, H.S.;Ryou, H.S.;Kang, J.G.;Park, J.Y.
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1814-1818
    • /
    • 2007
  • The Korea Railroad Research Institute developed a fire control system for coaches using water mist. The fire control technology using water mist is used in the fire control system embedded in coaches developed through research. Such environment-friendly, automatic fire-extinguishing device is also economical because the amount used is significantly less than that of the existing sprinkler system. The paper introduces the developed fire control system and fire control performance tests using such system.

  • PDF

Effectiveness of Friction Loss Calculation Used for Water Mist Fire Extinguishing System on Marine Vessels

  • Lee Kyung-Woo;Kim You-Taek;Lee Young-Ho;Kim Mann-Eung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.86-97
    • /
    • 2005
  • Nowadays, Water Mist Fire Extinguishing System is increasingly used in maritime field for various application. The fire extinguishing capability of the system should be verified by hydraulic calculation in the same manner as the conventional water based fire extinguishing system such as sprinkler system. water spray system and etc. Additionally, the review of effectiveness of friction loss calculation method used for hydraulic calculation is needed because the pipe flow characteristic of its piping system has higher Reynolds number than that of the conventional system. In this paper the review work was carried out based on the NFPA Code 750.

A Commodity Classification Method of Domestic Rack-Type Warehouse for Sprinkler System Design (스프링클러 설계를 위한 국내 적층형 물류창고의 수용물품 등급분류 방법)

  • Yang, So-Jin;Lee, Young-Jae;Kim, Woon-Hyung;Dewey, James M.;Ham, Eun-Gu
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.4
    • /
    • pp.531-539
    • /
    • 2019
  • Purpose: The purpose of this study is to present the commodity classification method of domestic rack-type warehouse for sprinkler system design. Method: On-site surveys and classification criteria of the NFPA, FMDS, EN and Japan were analysed and ISO 12949 test were carried out with proposed each classification commodity. Result: Based on a heat of combustion, a classification method for extra high, high, medium and low are proposed. Conclusion: Sprinkler design criteria to secure the maximum extinguishing strength for each class of commodity need to be applied.

Experimental study on smoke-logging phenomenon caused by sprinklers during a compartment fire (구획 화재시 스프링클러에 의한 스모크-로깅현상에 관한 실험적연구)

  • Kwon, Young-Jin;Yoon, Ung-Gi;Seo, Dong-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.121-122
    • /
    • 2014
  • This study contemplated the descending air current from the smoke layers related to the smoke logging phenomenon in the sprinkler applied design for effective evacuation safety design. As a result, database on the average particle diameter, particle velocity and distribution of sprinkling was obtained and the relationship between the water amount and particle diameter was obtained. Also, in relation to descending air current, the movement of smoke layer to the bottom at the descending air current velocity of 0.6m/s was observed and stable descending air current was observed in existence of fire source over 100kW in size.

  • PDF

Study on Guideline of Water Supply System for Forest Fire (산불방지 급수시설 설치 기준 마련에 관한 연구)

  • Kim, Dong-Hyun;Nam, Song-Hee;Keum, Si-Hoon
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.38-46
    • /
    • 2013
  • Permanent water supply and water sprinkling systems are essential to protect major forests and facilities from forest fire. Back in 2005, Naksan Temple, a valuable cultural asset of Korea, was burned down in a forest fire that took place in Yangyang. This started a series of movements including installing water supply facilities and managing forests near important cultural assets. As for the existing facilities, however, they were installed without any standard guidelines for management and installation according to each constructor's specifications, which were based on the National Fire Safety Code 109. Unfortunately, this is not effective in protecting facilities from forest fires such as they have a small protection area, limited simultaneous sprinkling, and a difficult the movement of fire hose. Against this background, the study examines the condition of water supply facilities currently in use, identifies their deficiencies, and suggests how to improve the criteria for water supply service to effectively prevent forest fire. Specifically, three systems were proposed: Water Sprinkler Tower System for preventing spread of crown fires, and Forest Fire Hydrant System and Portable Water Spray System to be effective for suppressing surface fires. In addition, the standards on the performance and components of water pumps are also suggested.

A study on optimization design of sealing for sprinkler fire pipe system (스프링쿨러 소방 배관용 시일의 최적설계에 관한 연구)

  • Kim, Kyung-Seob;Kim, Chung-Kyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.302-307
    • /
    • 2010
  • 본 연구는 최적설계 기법의 하나인 다구찌 방법을 이용하여 소방용 스프링클러 배관용 밀봉부에 대한 유한요소해석을 수행하고, 이를 통하여 소방용 배관의 밀봉안전성을 확보하고자 한다.

  • PDF

A Study on the Reliability of Automatic Sprinkler System in Clean Room (클린룸내 스프링클러시스템 신뢰성 향상에 관한 연구)

  • Hwang, Hwan-Sung;Song, Yun-Suk;Yoon, Myong-O
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.136-139
    • /
    • 2010
  • 본 연구에서는 일반 건물에 적용되는 스프링클러시스템에 비해 보다 높은 신뢰도를 요구하는 클린룸에서의 스프링클러시스템에 대해 국내 L사, S사 클린룸 건설 현장의 방문 조사를 통하여 최적의 소화효과를 발휘하며 신뢰도 향상을 위한 설계 및 시공기술 실태조사를 분석하여 클린룸 화재로부터 안전성을 확보 하고자 한다.

  • PDF