• 제목/요약/키워드: Fire Safety Test

검색결과 541건 처리시간 0.025초

케이블 화재의 화염전파 해석을 위한 FDS 모델의 격자민감도 평가 (Assessment of Grid Sensitivity in the FDS Field Model to Simulate the Flame Propagation of an Electric Cable Fire)

  • 김성찬;이성혁
    • 한국안전학회지
    • /
    • 제23권4호
    • /
    • pp.30-35
    • /
    • 2008
  • The present study has been conducted to examine the effect of grid resolution on the predicted results for electric cable fire using pyrolysis model in FDS(Fire Dynamics Simulator, version 5). The grid independent test for different grid resolutions has been performed for a PE coating cable and the grid resolution is defined by the non-dimensional characteristic length of fire and mean grid size. The calculated maximum heat release rate and mean flame spread rate were almost constant for higher grid resolution of 20${\sim}$25 and the computing time for the grid resolution takes approximately 20hours to solve flame propagation with pyrolysis model. The geometrical simplification of a electric cable dose not greatly affect on the maximum heat release rate and flame spread rate and the rectangular approximation of cable shape gives acceptable result comparing with the round cable with stepwise grid.

외벽 마감재료의 수직화재 확산 연구를 위한 실물화재 실험 (The Real Scale Fire Tests for Vertical Fire Spread Study of External Finishing Material)

  • 권오상;유용호;김흥열;김정현;민세홍
    • 한국화재소방학회논문지
    • /
    • 제26권6호
    • /
    • pp.85-91
    • /
    • 2012
  • 건축물에서 화재 시 인명과 재산의 피해를 줄이기 위해서는 초기의 화염의 확산을 억제하는 것이 우선되어야 한다. 화염의 확산을 방지하기 위한 화재확산방지 대책은 일반적으로 방화구획에서의 구조부재의 내화 성능 확보, 마감재료의 연소 성능에 따른 사용 제한 등이 있다. 마감재료의 연소 성능 판단은 화염의 확산을 판단하기 위해 가장 기초적인 화재 안전 설계이지만 국내의 연소 시험은 시편 크기의 화재 시험 방법으로 연소 성능을 판단하고 있어 샌드위치패널 등과 같은 복합재료의 연소 성능을 판단하기에는 많은 제약을 가지고 있다. 특히 외벽 마감재료의 경우 내부 마감재료에 비해 드라이비트, 알루미늄복합패널, 메탈패널 등과 같은 다양한 복합재료 등이 사용되고 있기 때문에 본 연구에서는 외벽 마감재료의 국제시험규격인 ISO 13785-2 시험방법을 통해 외벽 마감재료의 실물 화재 실험을 통해 외벽 마감재료의 수직화재 확산 특성을 판단하고자 하였다.

EMC Safety Margin Verification for GEO-KOMPSAT Pyrotechnic Systems

  • Koo, Ja-Chun
    • International Journal of Aerospace System Engineering
    • /
    • 제9권1호
    • /
    • pp.1-15
    • /
    • 2022
  • Pyrotechnic initiators provide a source of pyrotechnic energy used to initiate a variety of space mechanisms. Pyrotechnic systems build in electromagnetic environment that may lead to critical or catastrophic hazards. Special precautions are need to prevent a pulse large enough to trigger the initiator from appearing in the pyrotechnic firing circuits at any but the desired time. The EMC verification shall be shown by analysis or test that the pyrotechnic systems meets the requirements of inadvertent activation. The MIL-STD-1576 and two range safeties, AFSPC and CSG, require the safety margin for electromagnetic potential hazards to pyrotechnic systems to a level at least 20 dB below the maximum no-fire power of the EED. The PC23 is equivalent to NASA standard initiator and the 1EPWH100 squib is ESA standard initiator. This paper verifies the two safety margins for electromagnetic potential hazards. The first is verified by analyzing against a RF power. The second is verified by testing against a DC current. The EMC safety margin requirement against RF power has been demonstrated through the electric field coupling analysis in differential mode with 21 dB both PC23 and 1EPWH100, and in common mode with 58 dB for PC23 and 48 dB for 1EPWH100 against the maximum no-fire power of the EED. Also, the EMC safety margin requirement against DC current has been demonstrated through the electrical isolation test for the pyrotechnic firing circuits with greater than 20 dB below the maximum no-fire current of the EED.

샌드위치패널 벽면보호용 스프링클러설비 적용 실험 (An Experimental Study of Sprinkler system for Sandwich Panel Wall Protection)

  • 서동훈;김운형;김종훈;이영재
    • 한국화재소방학회논문지
    • /
    • 제31권5호
    • /
    • pp.37-43
    • /
    • 2017
  • 국내 샌드위치패널 건축물은 공장 창고시설의 벽 지붕에 널리 사용된다. 공장 창고시설은 용도특성상 화재하중이 높고 화재확산이 신속히 진행되어 대형화재로 이어지며 재료특성 상 벽 지붕이 무너져 인명피해 및 재산피해가 증가하고 있는 추세이다. 이를 위하여 본 연구에서는 샌드위치패널 스프링클러설비의 국내 외 관련기준을 검토하였다. 현장조사결과 가연물이 벽면에 밀착되어있는 경우가 있어 벽면으로부터 10 cm, 60 cm, 120 cm 이격하여 벽면보호여부를 확인하는 실험을 수행하였다. 화재실험결과, 방수압력 0.1 MPa, 방수량 K-80의 헤드 설치 시, 샌드위치패널착화방지를 확인하였다. 또한 가연물이 벽면으로부터 60 cm일 때 샌드위치패널벽면의 최고온도가 $525^{\circ}C$, 120 cm에서는 최고온도가 $276^{\circ}C$로 측정되었다. 한편, 국외소방연구기관의 EPS 샌드위치패널연구에 따르면 발화점이 $450^{\circ}C$인 것을 감안할 때, 패널 벽면에서 가연물거리는 120 cm 이상 이격하면 착화방지가 가능함을 확인하였다.

LNG 시험 플랜트의 정량적 위해도 평가를 위한 화재 및 폭발사고 해석 (Fire and Explosion Analysis for Quantitative Risk Assessment on LNG Test Plant)

  • 한용식;김명배;도규형;김태훈;최병일
    • 한국연소학회지
    • /
    • 제20권1호
    • /
    • pp.1-5
    • /
    • 2015
  • Fire and explosion analysis are performed for the quantitative risk assessment on the LNG test plant. From the analysis for a case of fire due to large leakage of LNG from the tank, it is obtained that loss of lives can be occurred within the radius of 60 m from the fire origin. Specially, wind can extend the extent of damage. Because the LNG test plant is not enclosed, the explosion overpressure is less than 6 kPa and the explosion has little effect on the integrity of the LNG test plant.

FRP 선박 기관실 난연성 향상을 위한 추가 방열재의 화재성능비교 (Comparison on the fire performance of additional insulation materials for improving the fire retardancy in engine-room of FRP vessel)

  • 최정민;엄한찬;진영화
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권9호
    • /
    • pp.1150-1155
    • /
    • 2014
  • 강화플라스틱(FRP) 선박은 화재 시 화염확산을 막기 위하여 관련 구조 기준에 따라 기관실 주위 벽 내부를 난연성 수지로 3회 이상 적층하거나, 이와 동등한 방열재로 둘러싸야한다. 관련 난연성 적층용 수지 및 일부 난연재료(연질폴리우레탄복합체)의 경우 선박용 물건의 형식승인 시험기준에 따라 그 성능을 평가할 수 있으나, 방열재로 빈번하게 사용되고 있는 '겔코트'에 대한 성능기준은 명확하지 않은 실정으로 난연성 수지와 화재안전성능이 비교 평가된 바 없다. 본 연구에서는 FRP 선박을 건조하는 조선소를 대상으로 설문조사를 실시하여 사용 중인 난연성 수지 3종, 겔코트 4종, 방염도료 1종 및 폴리우레탄 복합재 1종에 대해 화염전파시험과 방염성능시험을 적용하여 그 성능을 비교하였다. 화염전파시험 결과 임계열유속(CFE) 기준으로 각 종별 평균값을 비교하면 폴리우레탄 복합재, 난연성 수지, 방염도료, 겔코트 순으로 양호한 것으로 나왔고, 겔코트는 3회 도포한 것이 6회 도포한 것보다 양호한 결과를 보였다. 방염성능시험 결과 탄화면적 기준으로 각 종별 평균값을 비교하면 방염도료가 가장 좋게 나왔고 난연성 수지와 겔코트는 유사한 수준으로 나타났다.

산불진화용 안전복 패턴 개발을 위한 연구 (A Study on the Pattern Development for Forest Fire Safety Clothing)

  • 최미성
    • 한국의류산업학회지
    • /
    • 제13권4호
    • /
    • pp.624-634
    • /
    • 2011
  • The purpose of this study is to develop the pattern of safety clothes used at flat or mountainous areas and to identify the pattern of safety clothes by conducting experimental evaluation of virtual wear. Three subjects were selected, based on fire fighters' physical constitution. A prototype design for safety clothing was determined after in-depth interviewing of professionals and surveying of Forest service staff and related agency. Wearing test should be carried out in the order of pattern making, virtual and real wearing evaluation. For data analysis, technical statistical values should be obtained by using body measurements of subject, frequency analysis and T-test. The jacket is designed to have a front extension and the entire length of clothing enough for wearer to put on it over ordinary shirts or sweater. The collar of jacket is of round type. Cyber reality enables to identify the movement and activity of virtual fitting model and to find out errors or problems in safety clothing prior to on-the-spot wear test, thus raising the precision level of pattern. There was significant difference between real and virtual fit preference. The results show that the virtual try-on system need the development of a specific style.

화재현황 및 현장조사를 통한 ESS의 화재 위험성 연구 (A Study on the Fire Risk of ESS through Fire Status and Field Investigation)

  • 박광묵;김재현;박진영;방선배
    • 한국화재소방학회논문지
    • /
    • 제32권6호
    • /
    • pp.91-99
    • /
    • 2018
  • 최근 국내 ESS의 보급이 늘어나면서 화재사고 또한 발생하고 있다. 2018년 7월까지 총 7건이 발생하였다. 7건 모두 리튬이온배터리로 구성된 ESS 시스템으로 발화 이후 자동소화설비 또는 소방서에 의해 진화되지 못하고 전소되었다. 본 논문에서는 최근 발생한 ESS 화재현황 및 현장조사를 바탕으로 ESS 화재의 특징을 파악하고 발화원인을 환경적, 전기적, 열적 요인으로 나누어 분석하였다. 그 결과 ESS 화재가 시스템의 설치환경과 상관관계가 있음을 파악하였다. 국내외 리튬이온배터리 시험표준 및 ESS 시설기준 조사에서는 국내외 동향 및 차이점을 파악하였다. 화재현황 및 현장조사, 국내외 시설기준 조사 등을 토대로 ESS 화재 시 화재 확산을 방지하고 예방하기 위한 대책을 제시하였다.

성능위주설계의 신뢰성 확보를 위한 외국 사례 검토 (Reliability of the Performance-Based Design: International Cases)

  • 황준호;문성웅;최규출;유상훈
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 추계학술논문발표회 논문집
    • /
    • pp.151-154
    • /
    • 2011
  • 법률 중심적인 사양위주 설계의 한계를 극복하고자 국내 외 다양한 분야에서 성능위주 설계가 사용되고 있다. 국내에 도입된 소방 설비에 대한 성능위주 설계는 도입단계로 볼 수 있어, 선진국의 사례를 통해 도입 초기인 현재 발생할 수 있는 문제점과 대안을 분석하였다.

  • PDF