• Title/Summary/Keyword: Fire Safety Measures

Search Result 337, Processing Time 0.027 seconds

An Estimation of the Consequence Analysis for an Underground Installation of the LPG Storage Tanks (소형 LPG 저장탱크 매몰 설치에 대한 피해영향평가)

  • Song, Dong-Woo;Jun, Woon-Young;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.62-67
    • /
    • 2015
  • In this paper, the consequence analysis has been evaluated for the damage effects of the LPG storage tanks when they are installed on the ground or underground. They should be performed to identify measures to reduce risks for the LPG storage tanks which are more widely used. In order to conduct a damage effect evaluation of the LPG storage tanks installed underground, FDS was used to simulate the LPG storage tanks installed and housed within a facility. The maximum pressure of the storage facilities for the LPG storage tanks has been calculated from the FDS, and it's results are used as an input variable for Phast which is a commercial software for evaluating the damage effects. Getting results from the consequence analysis and computational simulations(diffusion range of LFL and UFL, jet fire or explosions) were quantitatively presented for the damage effects.

Development Plan for the Consequence Management in Response to Large-Scale Wildfire Disasters Using Air Force Transport Aircraft (C-130) (공군 수송기(C-130)를 활용한 대형산불 재난 대응 시 사후관리(CM) 발전방안)

  • Sangduk Kim;Minki Kim
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.232-243
    • /
    • 2024
  • Purpose: Recently, large-scale forest fires caused by climate change, natural disasters, and human factors have been increasing every year in the East Coast and Taebaek Mountains region. Although forest fire extinguishing using helicopters is currently increasing, the need to introduce air force transport aircraft has continued to be raised due to the importance of early fire extinguishment to respond to large forest fires and the difficulty of extinguishing forest fires between sheep. This study seeks to present a plan for developing a post-fire management system for several aspects - achieving operational objectives, overcoming the operating environment, selecting a staging area, and efficient operation measures - to efficiently perform forest fire extinguishing missions using Air Force transport aircraft. Method: Based on literature research on forest fire extinguishing, forest fire extinguishing experiments using fixed-wing aircraft, and the operation status and operation method of forest fire extinguishing helicopters, the pros and cons of helicopter operation and the effects of large forest fire extinguishing using a large transport aircraft (C-130) Analyze the effectiveness of operation through analysis. Results: When extinguishing a large forest fire, an effective CM (Consequence Management) application plan was derived, including effective operation, control, command system, dispatch request, and forest fire extinguishment when integrating helicopter and fixed-wing aircraft (C-130). Conclusion: The application of the concept of CM (Consequence Management) is partially applied to some areas of chemical, biological, and radiological (CBRNE) protection in Korea, but efficient operation, control, and command systems are established when integrated operation of helicopters and large aircraft (C-130) in forest fire extinguishment. the concept of CM (Consequence Management), which is operated in advanced countries, was applied for safety management, dispatch requests, and forest fire extinguishing, thereby contributing to the establishment of a more advanced disaster and post-disaster management system.

Perception of Patient Safety Risk Factors and Performance Level of Safety Care Activities among Hospital Nurses (환자안전 위험요인에 대한 병원간호사의 인식수준과 안전간호활동 수행정도)

  • Son, Young Shin;Lee, Young Whee;Kim, Young Shin;Song, Eun Jeong;Lee, Hye Ryun;Lee, Ju Hee
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.24 no.2
    • /
    • pp.190-200
    • /
    • 2018
  • Purpose: The purpose of this study was to identify the level of perception of safety risk factors and the degree of performance of safety nursing activities in order to develop an education program to improve the safety of patients. Methods: The subjects were 217 nurses from 3 university hospitals in Incheon. Data were collected with structured questionnaires and analyzed using descriptive analysis, t-test, and ANOVA using SPSS 22.0. Results: The level of perception of patient's safety risk factors and safety care activities was 2.93 and 4.68, respectively. Perception of patient safety risk factors which belonging to the risk type of therapeutic devices, equipment, service and infrastructure all scored below average; also in addition, behavior, performance, and violence risk type and work system, information and communication risk type showed relatively low perception levels. Safety nursing activities showed a low level of performance in accurate communication among medical teams, management of fire and disaster, security management, use of restraints, identification of patients, and correct performance of operations and procedures. Conclusion: Based on these results, it is necessary to improve the safety of patients by taking proper management measures along with education.

A Study on Measures to Achieve Performance and Safety of Air Respirators for Fire Fighters (소방대원용 공기호흡기의 성능안전확보 대책에 관한 연구)

  • Son, Bong-Sei;Oh, Suk-Hwan;Kim, Yeop-Rae
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.77-81
    • /
    • 2012
  • This study of aims to provide basic data for improve the performance of air respirators that generate by bad influencing elements in fire emergency field. With three types of conditions set up for these tests, the pressures of containers have been extracted; the ambient temperatures have been checked, and the generation of moisture inside and outside container have been checked and identified. Specifically, these tests have been conducted at temperatures ranging between $-20{\sim}40^{\circ}C$. The pressures of containers have been extracted to reach between 0.4~0.8 MPa, using a pressure regulating valve. These tests have resulted in no change in the temperature and moisture outside the containers and no generation of moisture inside the containers as well. Although moisture has been generated inside the pressure gauge, the amount of moisture has not exceeded 25 $mg/m^3$, i.e. the limit suggested by the Korean Government. Therefore, it is judged that the moisture generated inside air respirators, which can be the most critical issue in the equipment, is likely to be caused in the process of managing the equipment or replacing air in the equipment at places of end-users, rather than in the process of manufacturing and production of the equipment.

Hazard Evaluation of Runaway Reaction in Deboronation Process Using H2O2 in DIET Synthesis of Pharmaceutical Raw Material (의약품 원료 DIET 합성 중 H2O2를 이용한 붕소제거 반응공정에서의 폭주반응 위험성 평가)

  • Kim, Won Sung;Lee, Keun Won
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.4
    • /
    • pp.49-54
    • /
    • 2018
  • In the Active Pharmaceutical Ingredient(API) manufacturing company, since the product is produced by the chemical reaction, fire and explosion are frequently occurred in the process of inputting the raw powder as the chemical reaction stage. There are not many studies on safety measures through analysis of cause of accident in the actual chemical reaction stage. In this study, we investigated the heat flow in the boron removal reaction process to investigate the risk in the chemical reaction stage. The study reaction process was performed by using the reaction calorimeter for the products synthesized at the actual raw material in pharmaceutical factory. The risk was estimated by comparing the maximum temperature of the synthesis reaction, which can generate heat due to the failure of cooling in the actual manufacturing process, and the technical temperature. These results are applied to commercial manufacturing sites and safety measures to control the risk of runaway reaction due to reaction heat are suggested.

A Study on the Establishment and Revitalization Measures of International Safe Community -Based on Samcheok in Gangwondo- (국제안전도시 구축 및 활성화 방안에 관한 연구 -강원도 삼척시를 중심으로-)

  • Cho, Han-Sug;Shin, Ho-Joon;Baek, Min-Ho
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.3
    • /
    • pp.339-346
    • /
    • 2013
  • In this study, the summary and characteristics of WHO International Safe Community are examined and the activities for the establishment of safe city were analyzed targeting Samcheok City in Gangwon-do which prepares for the certification of the International Safe Community. And, based on the result, this study intends to present the direction of establishment and development of international safe city to improve the regional safety. First, for the establishment of safe city, measures and programs for vulnerable classes and accidential forms in the area must be developed and operated continuously. Second, continuous and systematic activities must be done by establishing combined network between regional government association and relative organ and resident association in the area. Third, public policies for establishing safe city so as to improve regional safety, such as enactment of relative si/do ordinance, etc, must be prepared so as to operate it systematically. Finally, through the various activities by establishing international network, education, publicity activities and various informations must be acquired.

Investigation of the Potential Risk for Musculoskeletal Disorders in Migrant Workers (외국인근로자의 근골격계질환 발생가능성에 관한 연구)

  • Lim, Hyung-Duk;Rajitha Kawshalya, Mailan Arachchige Don;Nam, Ki-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_2
    • /
    • pp.781-786
    • /
    • 2021
  • Korean domestic workers are trend to avoid harmful and dangerous jobs calls 3D work due to the poor working conditions. Therefore, the incoming population of foreign workers is increasing to fulfill the required labor force. Mostly these foreign workers are placed in small and medium-size industries. As work that induces musculoskeletal disorders(WMSD) is equally exposed to domestic workers as well as foreign workers, this study attempted to investigate the work burdened by musculoskeletal disorders and derive improvement measures by understanding the actual conditions of the worksites of foreign workers. The result of this investigation defines that the possibility of developing musculoskeletal disorders is very high in the environment in which more than 40% of the respondents work with heavy objects and repetitive work of wrists and elbows. To prevent the symptoms of musculoskeletal disorders among foreign workers, three measures were proposed. To reduce the mandatory check-up period of WMSD under the Occupational Safety and Health Act, to revise the employment permit system, and to enhance the practical help of EPS education. Safety and health management of foreign workers is becoming an essential task not only for securing a workforce but also for the national image. Personal and economic losses at the national level should be minimized through policy support such as financial support for small and medium-sized businesses in Korea and supplementation of legal systems for the protection of foreign workers.

A Study on Improvement of Safety Management in Subcontractor through Process Safety Management (공정안전관리를 통한 도급업체 안전관리 강화에 관한 연구)

  • Lee, Joo Yeob;Lee, Keun Won;Kim, Kyu-Jung;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.15-21
    • /
    • 2015
  • Looking at the large and small fire, explosion, or release accidents that occurred recently, we can see that the accident of subcontractor workers has been increased in the contractor workplace while a harmful or dangerous maintenance works. In this study, the actual status of subcontractor's safety management was examined by using the questionnaire to the contractor who submitted the process safety report. In order to improve the safety management of subcontractors, the responsibility and rational role-sharing between the contractors and subcontractors were reviewed. Also, Providing safety and health information and worker protection measures during maintenance were investigated. The results of this study can be used to help strengthen and improvement safety management of the subcontractor at the time of a hazardous or dangerous works. In addition, it will be utilized to reduce industrial accidents and to build mutual cooperation relationship between contractor and subcontractor.

Risk Assessment of Semiconductor PR Process based on Frequency Analysis of Flammable Material Leakage (반도체 PR 공정의 인화성 물질 누출 빈도분석을 통한 위험성 평가)

  • Park, Myeongnam;Chun, Kwang-Su;Yi, Jinseok;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.5
    • /
    • pp.1-10
    • /
    • 2021
  • Semiconductor Photo Resist (PR) automation equipment uses a mixture of several flammable substances, and when it leaks during the process, it can lead to various accidents, therefore, risk assessment is necessary. This study analyzed the frequency of leakage of Acetone and PGMEA used in PR automation equipment and the frequency at which such leakage could lead to a fire accident through the frequency analysis method, and evaluated the need for additional risk reduction measures in the current facility. Based on the process leak data and ignition probability data of IOGP, leak frequency analysis and ignition probability were derived, and the frequency of actual fire accidents was analyzed by combining them. The frequency of material leakage in semiconductor PR process is 7.30E-03/year, and fire accidents can occur by acetone that exists above the flash point when the material is leaked, the frequency was calculated at the level of 1.24E-05/year. According to the UK HSE, for a major accident occurring with a frequency of 1.24E-05/year, it is defined as "Broadly Acceptable", a level that does not require additional measures for risk reduction when it causes 7 or less deaths, and due to the process operated by two people, no additional risk reduction are required.

A Study on Damage Analysis Safety Distance Setting for LPG BLEVE (LPG BLEVE 피해분석 및 안전거리 설정에 관한 연구)

  • Kim, Jonghyuk;Lee, Byeongwoo;Kim, Jungwook;Jung, Seungho
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.6
    • /
    • pp.25-31
    • /
    • 2020
  • Boiling Liquid Expanding Vapor Explosion(BLEVE) can cause not only economic damage to the plant but also serious casualties. LPG accidents account for 89.6 percent of all accidents caused by gas leaks in Korea over the past nine years, while casualties from accidents also account for 73 percent of all accidents, according to statistics from the Korea Gas Safety Corporation. In addition, a potential explosion and a fire accident from one LPG storage tank may affect the nearby storage tanks, causing secondary and tertiary damage (domino effect). The safety distance standards for LPG used by LPG workplaces, charging stations, and homes in Korea have become stricter following the explosion of LPG charging stations in Bucheon. The safety distance regulation is divided into regulations based on the distance damage and the risk including frequency. This study suggests two approaches to optimizing the safety distance based on the just consequence and risk including frequencies. Using the Phast 7.2 Risk Assessment software by DNV GL, the explosion overpressure and heat radiation were derived according to the distance caused by BLEVE in the worst-case scenario, and accident and damage probability were derived by considering the probit function and domino effect. In addition, the safety distance between LPG tanks or LPG charging stations was derived to minimize damage effects by utilizing these measures.