• Title/Summary/Keyword: Fire Safety Manager

Search Result 32, Processing Time 0.025 seconds

Perception Difference Analysis between Manager and Field Worker about the Form work Collapse Accident (거푸집 붕괴재해에 대한 관리자와 작업자의 인식차이 분석)

  • Kang, Sung Won;Lee, Jun Heon;Park, Se Hwan;Kang, Ha Ram;Lee, Ki Seok;Kim, Baek-Joong;Shin, Yoon-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.179-187
    • /
    • 2021
  • In the past five years, form construction, which accounts for approximately 25% of the total construction period, has continued to occur without a significant decrease in the number of deaths, with the largest proportion of collapse accidents. Accordingly, this study analyzed the difference in perception between the manager and worker by a questionnaire survey on the degree of risk and safety management level regarding a mold collapse accident. The survey was conducted in three groups: safety manager, field worker, and field manager. The results of the survey were analyzed by an independent sample T-Test using the SPSS program. As a result, there was almost no difference in recognition between managers, but a significant difference in recognition between managers and workers. In addition, there was a difference in management perception between the administrator and worker, which clearly shows the difference in the position between the administrator who manages and supervises hazardous disaster factors and the worker who works directly in the field. Such differences in perception can be a factor that cannot be mitigated. Based on this study, more developed research can narrow the perception gap between managers and workers and be used as a basic material for disaster research.

Empirical Study to Strengthen the Disaster Management of Wooden Cultural Heritage - Focused on Concept and Range of Cultural Heritage Disaster Management and Investigation of On-site Manager (목조문화재의 안전관리 강화를 위한 실증적 연구 - 문화재 안전관리의 개념과 범주 및 현장 관리자 의식조사를 중심으로 -)

  • Lim, Suhng-bin;Ryu, Ho-cheol
    • Korean Journal of Heritage: History & Science
    • /
    • v.46 no.2
    • /
    • pp.96-113
    • /
    • 2013
  • The concept of disaster management of cultural heritage is not clearly established and the range and type of it is not organized yet. Also, there is an ever-present danger in the field control because there is no system that can provide safety of cultural heritage from various dangerous factors. Concretely, institutionally, the regulation of disaster management of cultural heritage remains limited and there are not enough reasonableness in installation and management of fire-fighting equipment and safety equipment. Also, we need to take an action to secure the safety of cultural heritage from its surroundings. In this research, we setup the concept, type and criteria for disaster management of cultural heritage to overcome limitations and problems of management of cultural heritage. In addition, in order to raise the level of disaster management of cultural heritage, this research proposes direction to reinforce the disaster management of cultural heritage by investigating and analyzing consciousness of security guards and fire-fighting officers.

Computer modelling of fire consequences on road critical infrastructure - tunnels

  • Pribyl, Pavel;Pribyl, Ondrej;Michek, Jan
    • Structural Monitoring and Maintenance
    • /
    • v.5 no.3
    • /
    • pp.363-377
    • /
    • 2018
  • The proper functioning of critical points on transport infrastructure is decisive for the entire network. Tunnels and bridges certainly belong to the critical points of the surface transport network, both road and rail. Risk management should be a holistic and dynamic process throughout the entire life cycle. However, the level of risk is usually determined only during the design stage mainly due to the fact that it is a time-consuming and costly process. This paper presents a simplified quantitative risk analysis method that can be used any time during the decades of a tunnel's lifetime and can estimate the changing risks on a continuous basis and thus uncover hidden safety threats. The presented method is a decision support system for tunnel managers designed to preserve or even increase tunnel safety. The CAPITA method is a deterministic scenario-oriented risk analysis approach for assessment of mortality risks in road tunnels in case of the most dangerous situation - a fire. It is implemented through an advanced risk analysis CAPITA SW. Both, the method as well as the resulting software were developed by the authors' team. Unlike existing analyzes requiring specialized microsimulation tools for traffic flow, smoke propagation and evacuation modeling, the CAPITA contains comprehensive database with the results of thousands of simulations performed in advance for various combinations of variables. This approach significantly simplifies the overall complexity and thus enhances the usability of the resulting risk analysis. Additionally, it provides the decision makers with holistic view by providing not only on the expected risk but also on the risk's sensitivity to different variables. This allows the tunnel manager or another decision maker to estimate the primary change of risk whenever traffic conditions in the tunnel change and to see the dependencies to particular input variables.

A Plan for Construction of the National Electrical Safety Grid to Prevent the Fires Caused by Electrical Faults (전기화재 예방을 위한 국가전기안전망 구축 방안)

  • Bae, Seok-Myeong;Jeon, Jeong-Chay;Park, Chan-Eom;Bae, Seok-Myeong;Ko, Won-Sig
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2267-2273
    • /
    • 2009
  • In this paper, in order to monitor and manage an electrical risk factor like as leakage current, load current, and arc-fault, a real time monitoring and management system being operated in the ubiquitous environment was developed, and a plan of construction of an electrical safety grid using the system was proposed. For confirmation of usefulness and reliability of the proposed safety system and grid, the developed intelligent panels were applied to 28 Korean traditional houses in Jeonjoo city, and the grid including the panels was operated. If the proposed National Electrical Safety Grid is completely constructed in the houses of general electrical users, the Grid will have an effect on that a main manager on electrical safety transfers from management system by general people to real-time management system by expert. As a result, the electrical fires caused by an over-load, an arc-fault, and an earth-fault will be prevented.

A Study on the Rehabilitation Room of Firefighters at Disaster Spot (재난현장 소방공무원의 회복실에 관한 연구)

  • Chae, Jin;Yim, Dong-Kyun
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.116-125
    • /
    • 2020
  • This study intends to provide a model for the establishment of a rehabilitation room for the safety and rehabilitation of firefighters by proposing a basis for the establishment of a firefighter rehabilitation room at disaster sites. To achieve the research objectives, a questionnaire, frequency analysis, and variance analysis were conducted to assess the effectiveness of rehabilitation rooms for firefighters. Based on the results of the research, the policy suggestions for operating an effective rehabilitation room are as follows. An organization of the operation of the rehabilitation room should be established at each firefighting headquarters, and human resources must be secured for the operation of the rehabilitation room. In addition, detailed operating standards such as the operation contents of the rehabilitation room's operation manager and its operator, as well as its operation procedures should be prepared. Additionally, training to improve the rehabilitation room and its understanding is needed.

Systematic Measure of The Safety Accidents 'Preparation Behavior Manual' in Campground (캠핑장 안전사고 '대비 행동 매뉴얼'의 체계화 방안)

  • Yi, Joo-Wook;Kim, Yun-Sang;Han, Dong-Soo
    • Journal of Digital Convergence
    • /
    • v.16 no.2
    • /
    • pp.441-449
    • /
    • 2018
  • This study is to organize the manual for the safety accidents in campsite. For this, analyzing the types of safety accidents and reviewing the regulations of campsite. Through theoretical considerations, the problem was diagnosed and the elements of improvement were presented. Eventually, part of the Responsive and Preventative Behavior manuals were developed to organize 'Preparation Behavior Manual'. Especially, examples of safety accident prevention behavior manual were divided into: 1st, suffocation, 2nd, traffic accident, 3rd, fire, 4th, and electrical accident. "S.A.F.E.", An example, was created with the accident specific initials that were more frequently caused. Furthermore, it was emphasized that it is necessary to process of understood by the user. Subsequent studies recommended the study of cases, improvement of safety management indicators, and the specialization of campground manager and safety guard.

A Study on Measurement of Length and Slope of Temporary Structure using UAV (무인항공기를 활용한 가설구조물의 길이와 기울기 측정에 관한 연구)

  • Min-Guk, Kang;Seung-Hyeon, Shin;JongKeun, Park;Jeong-Hun, Won
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.6
    • /
    • pp.89-95
    • /
    • 2022
  • A method for measuring the length and slope of a temporary structure using an unmanned aerial vehicle (UAV) and 3D modeling method is proposed. The actual length and slope of the vertical member of the specimen were measured and compared with the measured values obtained by the proposed method for the specimens with and without the vertical protection net installed. Based on the result of measuring the length of the temporary structure specimen using the UAV and 3D modeling method, the measured value showed an error of 0.87% when compared to the actual length in the specimen without the vertical protection net installed. In addition, the error of the slope was 0.63°. It was thought that the proposed method could be usable for the purpose of finding parts in wrong installation state on the temporary structure and informing the manager in charge. However, in the case of the specimen with the vertical protection net, the measurement showed a 1.46% error in length and 2.77° difference in slope. Therefore, if a vertical protection net is to be installed in a temporary structure, the measurement accuracy should be improved by utilizing an image processing method, etc.

Knowledge and Current Status about AED in the Public Facilities - Focused on the Gwangju City - (다중이용시설에서의 AED에 관한 지식 및 운영실태에 관한 연구 - 광주광역시 중심으로 -)

  • Park, Si-Goo;Park, Chang-Hyun;Chae, Min-Jung
    • The Korean Journal of Emergency Medical Services
    • /
    • v.14 no.3
    • /
    • pp.13-28
    • /
    • 2010
  • Purpose: In this study, we investigated the better application of the law which is about the AED installation and more effective ways of emergency medical care system, to understand the law and to research the current condition of public facilities which belong to local governments, and to seize the aspect of safety guards who currently work in order to provide the installation of AED in the public facilities and to provide more efficient emergency medical service with the effectuation of the immunity law of the good intention of first-aid treatment. Methods: In Gwang-ju, 234 public facilities have been identified by 31 December, 2008. With the exception of the duplication, we researched 158 facilities and received the answers from 95 of them. Results: In the research, 53% of them have had internal emergency first-aid education, and 55% of them didn't have this education and a CPR education manual, and 30% of the facilities even didn't know how to connect with the manager of the company for the first-aid department. On the other hand, most of them were highly interested in CPR and AED education on the ratio of 91% and 93%. 88% of them have been trained about first-aid, 51% of them haven't been retrained, 17% have never been trained. so, the reality of emergency system at public facilities is serious. 78% of them knew they are working at public facilities, though 49% of them didn't know about AED installation. 57% of them didn't know the fact there is the immunity law related with good intentions for first-aid treatment. 63% of the facilities have security guards, and 30% of them didn't answer the questions. Also, many of them agreed to the opinion that all employees should have first-aid training. At representative survey report of participator of public-facility, emergency treatment is 61%, 16% of patients calling. Accordingly they importantly think better doing an on-site first-aid than evacuating the patient. And the rates show that 57% of them answerers tend to call Fire-Office(119) for evacuating the patients, and 28% of them EMIC(1339) for the first-aid. Conclusions: In this study, we are suggest to improve the details of the efficient operations and management after the grasp of the uninstallation, indifference, and unreliable conditions of AED. 1) Need a publicity of AED install cognition which is an emergency medical instrument at public facilities. 2) Arrangement of safety agents at facilities and concerns about them for good management from the parties concerned. 3) Need a designation of legal details according to the decision of the AED installation and the standard of the AED installation. 4) Training about first-aid of safety guards and the persons concerned in the facilities should be practiced participation with the positive and through this, first-aid treatment could be done by anyone who knows the immunity law related to medical emergency. 5) The brochures for the potential users and the results form practicing the instructions need to be improved in many ways through recording the emergency cases that have happened.

  • PDF

Prevalence of Work-related Musculoskeletal Disorders in Auto-mission Assembly Plant Workers

  • Min, Seung Nam;Subramaniyam, Murali;Kim, Dong-Joon;Park, Se Jin;Lee, Heeran;Lee, Ho Sang;Kim, Jung Yong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.4
    • /
    • pp.293-302
    • /
    • 2015
  • Objective: This study was performed to investigate the prevalence of musculoskeletal disorders in auto workers of a mission assembly plants. Background: Most studies of musculoskeletal disorders have used car assembly line workers as their participants. However, little research has been done on musculoskeletal disorders afflictions of mission assembly line workers. Method: Through a focus group interview with an ergonomist and a manager at a mission assembly plant site, a questionnaire was developed for musculoskeletal disorders. The questionnaire consisted of five parts, demographic factors, musculoskeletal disorder symptoms, and musculoskeletal disorder experiences; 137 workers participated in this survey. The surveys were analyzed by correlation and Chi-squared analysis. Results: Musculoskeletal disorder symptoms and serious pain were reported in the neck, shoulder, back, and fingers. These problems were statistically related to various demographic factors, such as age, stature, stretching, and work satisfaction. Conclusion: Treatment of musculoskeletal disorders should consider the workers' traits. If there is no specific cause of the pain, developing stretches and exercises before and after work should be applied to prevent musculoskeletal disorders. Application: The results of this study can be used to develop guidelines to prevent injury in auto workers at mission assembly plants.

A Study on Hazards Assessment of Electrostatic Firing Explosion of Working Wears at LPG Stations in Korea (한국의 LPG 충전소에 있어서 작업복의 정전기에 의한 화재 및 폭발 위험성에 관한 연구)

  • Cho young doo;Koo Ja Hyeuk;Choi Kwang Seo;Seo Dae Won;Joung Jae Hee;Takeuchi Manabu
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.4 s.12
    • /
    • pp.20-24
    • /
    • 2000
  • The electrostatic safety consciousness of safety manager were investigated through questionnaires sent to liquid petroleum gas stations in Korea. In addition, hazards of fire and explosion due to electrostatic on synthetic-polymer-wears and cotton-wears were estimated experimentally. The results of questionnaires indicate most workers wear their working clothes indiscreetly owing to lack of knowledge of preventing electrostatic hazards. The amounts of electrostatic charge generated in synthetic-polymer-wears were 1.79, 1.44 and 1.02 $\mu$C in winter, spring and autumn and summer, respectively. All these values exceed the limit of working wears of 0.60$\mu$C requested by Korea Standard(KS K-7807) for preventing electrostatic hazards, which means hazards may occur. While, the charge in cotton-wears were in the range of 0.42 to 0.52$\mu$C, which suggests that the cotton-wears investigated in this study have no problem of hazards. Therefore workers, visual and experiential education are necessary for elevating the standard of on electrostatics. It is also necessary to establish standards of wearing for preventing electrostatic hazards.

  • PDF