• Title/Summary/Keyword: Fire Route

Search Result 128, Processing Time 0.024 seconds

A Study on the Efficiency of Smoke Barriers in the Subway Station (지하역사 제연경계벽의 제연 효용성에 관한 연구)

  • Kim, Bum-Kyu;Kim, Hee-Young;Lee, Sung-Mi;Park, Yong-Hwan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.204-208
    • /
    • 2008
  • Casualties Damage from Smoke is very serious consequence. Especially, Damage from smoke in in the Subway Station is the terrible result. Smoke from the fire in the Subway Station that evacuation route on the path and the sight of refugees caused by serious traffic problems. Accordingly, A study on Smoke barriers of smoke systems take into considerations relate to effects depending on wind velocity speed of the piston effect come into the retarding effect of smoke control in smoke barriers. As a result of modeling, According to increasing of Velocity in the platform which installed smoke barriers were been on the increase spreading quantity of smoke in the right direction of upstairs however, In contrast spreading quantity of smoke in the left direction on the upstairs were been on the decrease.

  • PDF

A Study on the Evaluation Method of the Building Safety Performance and the Prediction of Occupants′ Egress Behavior during Building Fires with Computer Simulation (컴퓨터시뮬레이션에 의한 피난행태예측 및 안전성능평가방법에 관한 연구(II))

  • 최원령;이경회
    • Fire Science and Engineering
    • /
    • v.3 no.2
    • /
    • pp.11-19
    • /
    • 1989
  • In this study, the independent variables are the floor plan configulation. The dependent variables are the occupant's egress behavior, especially spatial movement pattern, and life - safety performance of building. Fire events were simulated on single story of office building. Simulation run for allowable secaping thime(180 seconds) arbitrarily selected, and involved 48 occupants. The major findings Pre as follows. 1) Computer simulation model suggested in this study can be used as the Preoccupancy evaluation method of the life-safety performance for architectural design based on prediction of occupants' egress behavior in the levels of validity and sensitivity, 2) Sucess or failure in occupants' escape is determined by decreasing walking speed caused by jamming at exits or over crowded corridor, and increasing route length caused by running about in confusion at each subdivision and corridor. 3) In floor plan configuration which safe areas located at the extreme ends of the corridor, cellular floor planning have to be avoided preventing jamming and running about in confusion at overcrowded corridor.

  • PDF

Evacuation Safety Evaluation According to Slope of the School Ramps

  • Choi, Chang-Jun;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • v.10 no.1
    • /
    • pp.184-196
    • /
    • 2021
  • This study, in order to evaluate the safety of evacuation by comparing and analyzing the RSET according to the slope change of the ramp, which is a vertical evacuation route in case of fire in a high school building, Evacuation simulation was run the Pathfinder program changed the slope of the ramp to 10°, 15°, and 20° for each male students and female students. In the case of female students, it was analyzed that when the final RSET slope was 15°, 25.7 seconds were shorter than when 10°, and 4.2 seconds were shorter than when 20°. Male students also found that when the final RSET slope was 15°, 23.8 seconds were shorter than when 10°, and 5.4 seconds shorter than when 20°. It was analyzed that even if the number of participants was increased and the evacuation simulation was executed, the safety of evacuation could be improved when the slope of the slope is 15° as the RSET when the slope of the slope is 15° is shorter than that of 10° and 20°.

MULTI-SENSOR INTEGRATION SYSTEM FOR FOREST FIRE PREVENTION

  • Kim Eun Hee;Chi Jeong Hee;Shon Ho Sun;Jung Doo Young;Lee Chung Ho;Ryu Keun Ho
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.450-453
    • /
    • 2005
  • A forest fire occurs mainly as natural factor such as wind, temperature or human factor such as light. Recently, the most of forest fire prevention is prediction or prevision against forest fire by using remote sensing technology. However in order to forest fire prevention, the remote sensing has many limitations such as high cost and advanced technologies and so on. Therefore, we need to multisensor integration system that utilize not only remote sensing but also in-situ sensing in order to reduce large damage of forest fire though analysis of happen cause and prediction routing of occurred forest fire. In this paper we propose a multisensor integration system that offers prediction information of factors and route of forest fire by integrates collected data from remote sensor and in-situ sensor for forest fire prevention. The proposed system is based on wireless sensor network for collect observed data from various sensors. The proposed system not only offers great quality information because firstly, raw data level fuse different format of collected data from remote and in-situ sensor but also accomplish information level fusion based on result of first stage. Offered information from our system can help early prevention of factor and early prevision against occurred forest fire which transfer to SMS service or alert service into monitoring interface of administrator.

  • PDF

Evaluation on Fire Available Safe Egress Time of Commercial Buildings based on Artificial Neural Network (인공신경망 기반 상업용 건축물의 화재 피난허용시간 평가)

  • Darkhanbat, Khaliunaa;Heo, Inwook;Choi, Seung-Ho;Kim, Jae-Hyun;Kim, Kang Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.111-120
    • /
    • 2021
  • When a fire occurs in a commercial building, the evacuation route is complicated and the direction of smoke and flame is similar to that of the egress route of occupants, resulting in many casualties. Performance-based evacuation design for buildings is essential to minimize human casualties. In order to apply the performance-based evacuation design to buildings, it requires a complex fire simulation for each building, demanding a large amount of time and manpower. In order to supplement this, it would be very useful to develop an Available Safe Egress Time (ASET) prediction model that can rationally derive the ASET without performing a fire simulation. In this study, the correlations between fire temperature with visibility and toxic gas concentration were investigated through a fire simulation on a commercial building, from which databases for the training of artificial neural networks (ANN) were created. Based on this, an ANN model that can predict the available safe egress time was developed. In order to examine whether the proposed ANN model can be applied to other commercial buildings, it was applied to another commercial building, and the proposed model was found to estimate the available safe egress time of the commercial building very accurately.

Implementation of EO/IR Camera for Fire-fighting of Narrow Space (협소거주공간 진화를 위한 EO/IR카메라 구현)

  • Park, Hyun-Ju
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.628-629
    • /
    • 2018
  • Recently, residential spaces in urban areas have changed into multi - family residential spaces. There is a feature that smoke is charged when a fire occurs here. Also, the evacuation route and the direction of the outflow of smoke are the same, and the possibility of inhaling the smoke of the evacuees is very high. When fighting fire in a narrow residential space such as a dwelling in a downtown area, exploration is the most important. For this purpose, we implement EO / IR sensor which can be mounted on firefighter 's helmet and can be used for fire detection. By using the EO / IR operation test, we can derive the results that can be used for research and development of the fire search sensor.

  • PDF

Numerical Analysis on Pressurization System of Smoke Control in Consideration of Flow Rate of Supply and Leakage (보충량과 누설량을 고려한 급기가압 제연시스템의 수치해석 연구)

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.87-93
    • /
    • 2010
  • The fact that the smoke hinders evacuation and fire-fighting activities as well as becomes the major cause of life casualty emphasizes the importance of smoke control system. As one of the fire safety standards designed to secure the smoke safety, NFSC501A (Design Guide for Smoke Control System of Special Evacuation Stairwell and Lobby) has been proposed, preventing smoke from penetrating into the smoke-free escape route by raising the pressure of the smoke control zone higher than fire area. For model building of 20 stories, pressurization system was designed according to standard and pressure field of compartments in whole building induced by pressurization system was analyzed using the network model.

A Numerical Simulation of Smoke Control in Daegu Subway Stations II. Air Flowrate of Extraction System (대구 지하철역 제연의 문제점과 대책 II. 배기방식 제연설비의 풍량)

    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.105-110
    • /
    • 2003
  • In Part II, the temperature and smoke particle distributions of the extraction system, which yielded the best smoke removal performance among the three smoke control systems in Part I, for extraction flowrates of 0.6∼2.4 ㎥/s and two fire sizes of 200 ㎾ and 2 ㎿ were presented. The same numerical method was utilized to the same computational domain and configurations as Part I. It was shown that the extraction flowrate affects the smoke control performance significantly, and that a similar trend in improving the smoke removal performance with the increasing extraction flowrate between the two fire sizes. An extraction flowrate of 2.4 ㎥/s or higher was required for the temperature in the escape route less than $^{\circ}C$ for the given situations.

A Study on Evacuees Risk Assesment for Application of Spatial Risk Information (공간위험정보를 적용한 대피자 위험성평가에 관한 연구)

  • Hong, Seungbum;Jang, Jae-Soon;Park, Hyun-A;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.8-12
    • /
    • 2015
  • Performance Based Design is evaluating after each calculatiuon ASET and RSET. Risk informaion values such as heat, smoke, toxic gas etc are extracted by FDS in this study. These Risk informaion values by FDS apply Artisoc (evacuation simulator). Building structure made $60m{\times}65m$, exit number is made 2 positions and people in this building are 50 ramdonly. 20 times (case1~case 20) simulated and analysis evacuees risk by evacuated route positions.

Fire Evacuation Simulation Using FFM and FDS (FFM과 FDS를 이용한 화재 대피 시뮬레이션)

  • LEE, Jae-Young;LEE, Min-Hyuck;JUN, Chul-Min
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.21 no.2
    • /
    • pp.56-67
    • /
    • 2018
  • In general, fire and evacuation simulators are used independently to diagnose the safety of building. Because this method does not reflect the movement of pedestrians considering fire spread, it is difficult to expect diagnosis of safety with high accuracy. In this study, we propose the simulation method that can describe the movement of pedestrians in the fire emergency. Our method reflects the FDS fire spread data into FFM and explains the situation in which a pedestrian recognize a fire and escapes to a safe route. This study consists of data linkage between FDS and FFM and development of improved FFM. Experiment of the proposed method is progressed using the EgresSIM. Simulation result shows that the number of evacuees on each exit is affected by the presence or absence of fire and it was confirmed that the evacuation time increase and the bottleneck phenomenon deepened by exit.