• 제목/요약/키워드: Fire Road

검색결과 201건 처리시간 0.024초

경유와 메탄올의 유출속도에 따른 화재특성 (Fire Characteristics for Spill Rate of Light oil and Methanol)

  • 이정윤;김홍
    • 한국안전학회지
    • /
    • 제31권5호
    • /
    • pp.54-60
    • /
    • 2016
  • In this study, tank truck incidents of road transport of hazardous materials to experimental investigated the potential fire hazard. Real scale fire was to perform experiments for on this qualitative and quantitative data collection and analysis. Particularly affected by radiant heat from the flames caused and damage estimates range investigated accordingly. Flame temperature, internal temperature of tank and emitted radiation from the flames was investigated. The flame of light oil spill caused a fire at a temperature of about $300^{\circ}C$ high in comparison with the methanol by combustion of diesel and methanol, according to the difference, the flame duration changes varies depending on the Burning rate. Depending on spill rate(30, 60, 90 and $120{\ell}/min$) and the longer the duration of the flame important factors for the internal temperature of tank lorry rise was found. Road accident in a fire caused by leakage of hazardous was could the higher the damaged. Therefor, Fire suppression activities should be required in particular to be around.

도로터널 방재시설의 소방관계법령 개선방안 (Improvement Plan of Fire-Related Laws of Disaster Prevention Facilities of Road Tunnels)

  • 서효선;황영권;이승철
    • 한국화재소방학회논문지
    • /
    • 제33권2호
    • /
    • pp.124-131
    • /
    • 2019
  • 도로터널에서 화재가 발생하면 밀폐된 구조적 특성상 대형재난으로 발전할 가능성이 높기 때문에 각종 방재시설이 잘 설치되어 화재예방과 대응에 제 기능을 발휘해야 한다. 연속터널의 연장 및 방음터널을 고려하지 않아 필수 방재시설의 설치가 누락되어 법령의 개정이 필요한 것으로 판단된다. 이에 따라 본 논문에서 도로터널의 방재시설과 관련한 국내 법령들의 변천사항을 검토하고, 각 법령 간 비교분석을 통해 소방관계법령에서 개정이 필요한 부분을 연구한 결과는 다음과 같다. 첫째, 연속터널은 개별터널의 연장의 합을 고려하도록 하고 방음터널이 터널의 범주에 포함되도록 하여 필수 방재시설이 설치가 되지 않는 일이 없도록 해야 한다. 둘째, 터널 내 방재시설 설치의 법적 당위성 확보가 필요하므로 터널에 설치가 제외된 시설인 미분무소화설비, 비상방송설비, 유도등이 법령에 명시될 필요가 있다. 셋째, 현장대응의 입장에서 터널 내에 공기호흡기를 비치하도록 명시하여 소방대원들의 진압활동 및 인명구조에 크게 기여할 수 있도록 한다.

도로터널내 화재 발생시 매연 제거를 위한 모델 해석 (A Model-Analysis for Removal of Fire Fumes in a Road Tunnel during a Fire Disaster)

  • 윤성욱;이희근
    • 터널과지하공간
    • /
    • 제7권2호
    • /
    • pp.100-107
    • /
    • 1997
  • In case of a fire outbreak in a uni-directional road tunnel, the flow of traffic immediately behind the fire disaster will be stalled all the way back to the entrance of the tunnel. Furthermore, when the vehicle passengers try to flee away from the fire toward the entrance of the tunnel, the extremely hot fume that propagates in the same direction will be fatal to the multitudes evacuating, but may also cause damage to the ventilation equipments and the vehicles, compounding the evacuation process. This paper will present the 3-dimensional modelling analysis of the preventive measures of such a fume propagation in the same direction as the evacuating passengers. For the analysis, the fire hazard was assumed to be a perfect combustion of methane gas injected through the 1 m X 2 m nozzle in the middle of the tunnel, and the product of $CO_2$ as the indicator of the fume propagation. From the research results, when the fire hazard occurred in middle of the 400 m road tunnel, the air density decreased around the fire point, and the maximum temperatures were 996 K and 499 K at 210 m and 350 m locations, respectively, 60 seconds after fire disaster occurred, when the fumes were driven out only towards the exit-direction of the tunnel. By tracing the increase of $CO_2$ level over 1% mole fraction, the minimum longitudinal ventilation velocity was found to be 2.40 m/sec. Furthermore, through Analysis of the temperature distribution graphs, and observation of the cross-sectional distribution of $CO_2$ over 1% mole fraction, it was found that the fume did not mix with the air, but rather moved far in a laminar flow towards exit of the tunnel.

  • PDF

도로터널내부 화재시의 열전달 및 연기거동에 따른 피난안전성평가에 관한 수치적 연구 (Numerical Simulation on the Heat Transfer and Smoke Flow Phenomena and Evacuation in the Road funnel Fires)

  • 민동호;손봉세
    • 한국화재소방학회논문지
    • /
    • 제19권1호
    • /
    • pp.87-92
    • /
    • 2005
  • 본 연구에서는 도로터널 화재에 따른 열 전달 및 연기거동의 특성과 피난시뮬레이션에 대하여 수치적 연구를 수행하였다. 화재발생부분의 발열량은 30MW이며, 수치해석에 사용된 난류모델은 표준 $\kappa-\varepsilon$ 모델을 사용하였다. 도로터널에서 열기류 및 연기의 이동경로 형태를 예측하여 방재 및 피난 시스템을 구축하는데, 도로터널 설계 시에 유용한 자료로 이용될 수 있다.

도로터널 화재시의 환기분석 (The Analysis of Ventilation of Road Tunnel in Fire)

  • 김성준;류진웅
    • 산업기술연구
    • /
    • 제23권A호
    • /
    • pp.9-13
    • /
    • 2003
  • Numerical experiments are done by a commercial code, PHOENICS to evaluate the backlayer phenomenon of smoke in case of the road tunnel fire. The independent and dependent variables are ventilation air velocity and the length of backlayer of smoke respectively. Hybrid scheme and ${\kappa}-{\varepsilon}$ turbulence model are adopted in the simulation process and mass residual is used as a convergence criterion. The experimental results say that the length of backlayer is reduced with the increase of ventilating air velocity and that there is a critical air velocity which prevents from the onset of backlayering phenomena. One finds that there is a fresh air region near the bottom of tunnel which could make the passenger escape safely from the polluted region by smoke. These phenomena come from the vertical stratification of the smoke air mixture in the tunnel.

  • PDF

도로터널 위험도 평가프로그램 개발에 관한 연구(I) (The study of development of quantitative risk assesment program for the road tunnel)

  • 유지오;신현준;이동호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.460-467
    • /
    • 2006
  • Some large accidents in tunnels in recent years, such as Mont Blanc, Gotthard and Tauern tunnels, have lead to an increasing attention for tunnel safety and necessity of tool for quantitative risk assesment of road tunnel. And the purpose of this study is to develop the quantitative risk assesment tool for the application of road tunnel. The objectives of this paper are as follows : (1) analyze of traffic accident rates in tunnel, (2) make out scenario for fire accidents, (3) develop the evacuation model and FED calculation model, (4) Present the results from quantitative risk assesment for the model tunnel according with the fire heat release rates and distances of cross passage.

  • PDF

비선형 유한요소해석을 이용한 철근콘크리트 구조물의 내화성능평가 (Fire Endurance Estimate of Reinforced Concrete Structure Using Nonlinear Finite Element Method)

  • 변순주;임정순;황지욱
    • 한국방재학회 논문집
    • /
    • 제6권1호
    • /
    • pp.17-27
    • /
    • 2006
  • 화재동안 구조물의 복잡한 거동을 이해하기란 쉽지 않다 때문에 화재이후의 철근콘크리트 구조물의 잔류 강도를 평가하는 것은 매우 힘든 일이다. 그러나 교통시설의 화재로 인한 피해는 매우 크므로 화재에 대한 안전성 확보는 결코 간과해서는 안 될 중요한 요소이다. 따라서 이런 큰 피해를 줄이기 위한 철근콘크리트 구조물에 대한 정확한 내화성 평가 방법이 절실히 요구된다. 본 연구에서는 철근콘크리트 구조물의 내화성 평가를 위한 비선형 유한요소해석방법의 유효성을 증명하였고, 비선형 유한요소해석방법에 의한 지하차도 내화성 평가 결과를 ACI 216R-89의 결과와 비교하였다.

축사 화재의 현황과 그 방지 대책 -전라북도를 중심으로- (The Present Situation and Preventive Measure of the Fire in the Cattle Shelter -Based on Jeonbuk Province-)

  • 정기성
    • 한국화재소방학회논문지
    • /
    • 제21권4호
    • /
    • pp.81-87
    • /
    • 2007
  • 근래에 축사가 화재로 인하여 큰 피해가 발생하고 있다. 또한 화재로 피해를 입은 축사를 재건축하기가 매우 어렵다. 이러한 화재로부터 축사를 보호하기 위해서 철저한 재검토가 필요하다. 소방서에서 화재를 예방하는 대에는 한계가 있다. 무엇보다도 축사를 운영하는 사람이 어떻게 예방할 것인가를 아는 것이 중요한데, 축사를 화재로부터 예방하는 것을 명백히 세분할 필요가 있다. 화재로부터 축사를 안전하게 보호하는 것이 중요하다. 축사관리자는 화재를 진압하는 장비를 갖추어야 한다. 대부분의 축사화재는 전기에서 기인된다. 따라서 전기시설의 재정비가 필요한데, 소방서나 한전과 같은 기관의 도움이 필요하다. 축사소유자나 그 종사자들에게 화재발생 원인을 소방 교육을 통하여 알려야 한다. 소방서는 매년 발생하는 축사화재에 대비하여 소방도로나 장비, 경보시설 등을 정비하고 소방훈련 등을 실시하는 것이 화재예방에 도움에 될 것이다.

도로 터널 스마트관리를 위한 디지털 트윈 및 지능형 레일 로봇 개발 (Development of Digital Twin and Intelligent Monorail Robot for Road Tunnel Smart Management)

  • 손영우;박재홍;김응욱;정영식
    • 한국산업융합학회 논문집
    • /
    • 제27권1호
    • /
    • pp.25-37
    • /
    • 2024
  • The objective of this study was to create intelligent rail robots that are optimized for facility management and implement digital twin systems for smart road tunnel management. An autonomous surveillance system is formed by combining the sensing platform consisting of railing robots, fixed cameras and environmental detection sensors with the digital twin data platform technology for tunnel monitoring and early fire suppression. In order to develop mobile rail robots for fire extinguishing, we also designed and manufactured robots for extinguishing & monitoring and fire extinguishing devices, and then we examined the optimization of all parts. Our next step was to build a digital twin for road tunnel management by developing continuous image display system and implementing 3D modeling. After constructing prototypes, we attempted simulations by configuring abnormal symptom scenarios, such as vehicles fires. This study's proposal proposes high-accuracy risk prediction services that will enable intelligent management of risks in the tunnel with early response at each stage, using the data collected from the intelligent rail robots and digital twin systems.

도로터널 화재 시 외부 바람에 의한 연기거동 특성에 관한 실험적 연구 (An Experimental Study on Smoke Movement by the External Wind in Road Tunnel Fires)

  • 이성룡
    • 터널과지하공간
    • /
    • 제24권4호
    • /
    • pp.308-315
    • /
    • 2014
  • 본 연구에서는 도로터널 화재 시 외부 바람에 의한 영향을 평가하기 위하여 축소모형 실험을 실시하였다. $1.1m{\times}0.5m{\times}50.4m$ 모형 터널에서 휘발유 4.5리터를 사용하여 실험을 실시하였다. 터널 내부의 온도, 산소와 일산화탄소 농도를 측정하였다. 외부 바람의 영향에 따라 연기의 출구 도달 시간에 차이를 보였다. 최성기 이후에는 외부 바람의 영향이 초기에 비하여 작은 것을 확인할 수 있었다. 화재로 인하여 발생한 일산화탄소가 1,500 ppm 이상 도달하여 피난자에게 치명적인 위해를 가할 수 있다.