• 제목/요약/키워드: Fire Resistance Performance

검색결과 476건 처리시간 0.027초

주거용 내화단면 중공슬래브의 휨거동 평가 (A Evaluation on Flexural Behavior for Hollow Core Slab of Fire Resistance section for Residence Building)

  • 부윤섭;배규웅;신상민
    • 한국공간구조학회논문집
    • /
    • 제23권2호
    • /
    • pp.61-68
    • /
    • 2023
  • A two-hour fire-resistance PC hollow slab for residential use was developed to secure structural and fire-resistance performance and to be applied to the general building and apartment housing markets. Compared to the existing hollow slab, in order to secure the same or better structural performance and economic feasibility by reducing the quantity, it was attempted to secure the fire resistance performance by reducing the concrete filling rate in the cross section and adjusting the thickness of the upper and lower flanges by optimizing the hollow shape in the cross section of the slab. For structural performance evaluation, experiments were performed on PC hollow slabs by varying the member thickness and the presence or absence of overlaid concrete, and all of the experimental results showed that the design strength was sufficiently exhibited and that stability during construction was possible. The developed synthetic PC hollow slab has secured fire resistance and residential performance so that it can be applied to all buildings, and it is intended to be immediately applied to the field.

축력비 조건에 따른 철근콘크리트기둥의 내화성능에 관한 연구 (A Study on the Fire Resistance Performance of Reinforced Concrete Columns according to Axial Load Ratio)

  • 황규재;조범연;여인환
    • 한국화재소방학회논문지
    • /
    • 제27권6호
    • /
    • pp.26-31
    • /
    • 2013
  • 본 연구의 목적은 성능적 내화설계를 기반으로 한 철근콘크리트 기둥의 내화성능 평가를 최종 목표로 철근콘크리트 기둥의 열전달 해석을 통한 온도분포와 재하가열실험을 통한 수축량으로 적정 축력비를 도출하여 성능설계를 위한 기초 자료로 활용하고자 하는데 있다. 편심이 전혀 없는 순수축력을 기준으로 축력비 0.30, 0.35, 0.40, 0.47을 재하한 결과, 0.40 이상의 축력비를 확보하여야 내화성능을 만족할 수 있다고 판단하였다.

Fire Resistance Performance of FRP Rebar Reinforced Concrete Columns

  • Wang, Hui;Zha, Xiaoxiong;Ye, Jianqiao
    • International Journal of Concrete Structures and Materials
    • /
    • 제3권2호
    • /
    • pp.111-117
    • /
    • 2009
  • Concrete columns reinforced with Fibre Reinforced Polymer (FRP) rebar have been increasingly used in civil engineering applications, while the research on fire resistance of such structural members is still very limited. In this paper, attempts are made to predict temperature distribution and mechanical performance of FRP rebar reinforced concrete columns in fire. The effect of concrete cover and section size on fire resistance time is studied by the finite element method. Based on a parametric study, a simple empirical formula to predict fire resistance time is proposed for possible adoption in fire resistance design.

경계조건에 따른 고강도 H형강 부정정 보부재의 해석적 내화성능 연구 (Study on Fire Resistance Performance According to Boundary Conditions for Beams Made of High-Strength Structural Steels Using Analytical Methods)

  • 권인규
    • 한국화재소방학회논문지
    • /
    • 제29권5호
    • /
    • pp.23-28
    • /
    • 2015
  • 건축물의 공간 효율성 증대를 주 목적으로 고강재 강재(SM 520)의 사용이 활성화되고 있으나, 화재와 같은 고온조건에서의 보부재에 대한 내화성능은 검증되지 못하고 있는 실정이다. 따라서 본 연구에서는 SM 520강재가 적용된 양단 고정단 경계조건인 부정정 보부재를 대상으로 표준화재온도곡선과 고온에서의 항복강도, 탄성계수 그리고 비열, 선팽창계수를 적용하는 해석적 방법을 통하여 내화성능을 평가하고, 이를 바탕으로 일반 구조용 강재에 의한 보부재의 내화성능 평가의 안전성을 확인하였다.

Probabilistic seismic and fire assessment of an existing reinforced concrete building and retrofit design

  • Miano, Andrea;de Silva, Donatella;Compagnone, Alberto;Chiumiento, Giovanni
    • Structural Engineering and Mechanics
    • /
    • 제74권4호
    • /
    • pp.481-494
    • /
    • 2020
  • In this paper, a probability-based procedure to evaluate the performance of existing RC structures exposed to seismic and fire actions is presented. The procedure is demonstrated with reference to an existing old school building, located in Italy. The vulnerability assessment of the building highlights deficiencies under both static and seismic loads. Retrofit operations are designed to achieve the seismic safety. The idea of the work consists in assessing the performance of the existing and retrofitted building in terms of both the seismic and fire resistance. The seismic retrofit and fire resistance upgrading follow different paths, depending on the specific configuration of the building. A good seismic retrofit does not entail an improving of the fire resistance and vice versa. The goal of the current work is to study the variation of response due to the uncertainties considered in records/fire curves selection and to carry out the assessment of the studied RC structure by obtaining fragility curves under the effect of different records/temperature. The results show the fragility curves before and after retrofit operations and both in terms of seismic performance and fire resistance performance, measuring the percent improving for the different limit states.

비금속관 설비관통부의 슬리브 종류에 따른 내화성능 비교 (Comparison of the Fire Resistance Performance of Firestop Systems on Non-Metallic Pipes, Based on the Type of Through-Penetration Sleeve Used)

  • 정아영;최홍범;박진오;이형도
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.301-302
    • /
    • 2023
  • In this study, we aimed to identify changes in fire resistance according to the type of sleeves used for pipe penetrations and to examine their accreditation of fire resistance performance and use them as basic data. The test results of fire resistance according to the type of sleeve used in non-metallic pipe facilities showed that the temperature on the support side was higher for sleeves with higher thermal conductivity. For the temperature on the surface of the pipes, in the case of galvanized steel plates, steel pipes, and structures without sleeves, the highest temperature was observed after the expansion of the firestop material for 46 to 53 minutes and then decreased. PVC sleeves showed a steady increase in temperature until 53 minutes, after which the temperature did not increase further. In addition, for non-metallic pipes, the effect of the type of sleeve on fire resistance is considered to be insignificant because the lower part (heating direction of the furnace) under the support structure is cut off to block the heat during the two-hour fire resistance test.

  • PDF

Enhancing the Fire Performance of Concrete-Filled Steel Columns through System-Level Analysis

  • Fike, R.S.;Kodur, V.K.R.
    • 국제초고층학회논문집
    • /
    • 제2권1호
    • /
    • pp.11-21
    • /
    • 2013
  • The use of concrete filling offers a practical alternative for achieving the required stability of steel Hollow Structural Section (HSS) columns under fire conditions. However, current methods for evaluating fire resistance of Concrete Filled Hollow Structural Steel (CFHSS) columns are highly conservative as they are based on an elemental approach without due consideration to structural interactions that occur in framed structural systems. To overcome this limitation, a system level fire resistance analysis was carried out by treating CFHSS columns as part of an overall structural frame. In this analysis, an eight story steel-framed building was modeled under a range of standard and performance-based fire scenarios (including multi-story progressive burn-out fires) to evaluate the contribution of various structural members/assemblies to overall fire resistance. One of the primary factors considered was the use of concrete filling in HSS columns as an alternative to standard W-shape columns. Results from the analysis indicate that the use of CFHSS columns, in place of W-shape columns, in a performance-based environment can fully eliminate the need for applied fire protection to columns, while providing the required level of structural fire resistance.

단면크기 및 피복두께 변화에 따른 철근콘크리트 기둥의 내화성능에 관한 실험적 연구 (An Experimental Study on the Fire Resistance Performance of the Reinforced Concrete Columns According to the Cross Section Size and Depth of Concrete Cover)

  • 조경숙;여인환;조범연;김흥열;민병렬
    • 한국화재소방학회논문지
    • /
    • 제25권1호
    • /
    • pp.78-84
    • /
    • 2011
  • 최근 콘크리트 내화 연구는 대부분 고강도 콘크리트의 내화성능 확보에 많은 초점이 맞추어져 있다. 그러나 국내의 콘크리트 수요를 살펴보면 40MPa 이하의 일반강도 콘크리트의 수요가 전체 콘크리트 수요량의 대부분을 차지한다. 따라서 고강도 콘크리트의 내화성능에 대한 연구뿐만 아니라 일반콘크리트의 내화성능에 관한 연구도 필요하다. 본 연구에서는 40MPa 콘크리트 기둥을 대상으로 콘크리트 피복 두께와 단면크기를 변수로하여 내화성능을 평가하였으며, 연구 결과 단면크기가 커질수록, 피복두께가 두꺼워질수록 내화성능은 향상되는 것으로 나타났다.

철골 철근콘크리트 보 및 철골철망 모르타르조 보의 전열특성 및 화재거동에 관한 실험적 연구 (An Experimental Study on The Fire Resistance Performance of Steel Encased Reinforcement Concrete and Steel Framed Mortar Beam with Loading Condition)

  • 김형준;김흥열;여인환;권기혁;권인규
    • 한국화재소방학회논문지
    • /
    • 제26권1호
    • /
    • pp.80-88
    • /
    • 2012
  • 본 연구에서는 건축물의 피난 및 방화에 관한 규칙 제3조에 명시된 법정내화구조 중 보의 내화성능을 평가하고, 국내외 규정과 비교 및 분석을 하였다. 현행 규칙에 따르면 국내의 법정내화구조는 피난 및 방화구조에 관한 규칙의 시방기준을 만족하면 최대 3시간의 내화성능을 갖는 것으로 본다. 법정내화구조로서 보는 총 5개의 구조가 있으나, 본 연구에서는 우선 철근콘크리조를 대상으로 피복두께에 따른 내화성능을 평가하였다. 실험결과 하중비 0.5와 피복두께 40 mm를 확보할 경우, 최대 법정요구내화시간인 3시간을 만족하는 것으로 나타났다. 철골철망 모르타르조 보의 경우, 피복두께 60 mm 하중비 0.4에서 3시간 내화성능을 확보할 수 있다.

환경시험방법에 의한 내화도료의 내화성능에 관한 실험적 연구 (An Experimental Study on the Fire Resistance Performace of Intumescent Coating System by Environmental Testing Procedure)

  • 박수영;성시창;최동호;김대회;이세현;이종찬
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.69-72
    • /
    • 2008
  • This study is designed to understand changes in fire resistance performance of intumescent coating system through follow-up tests on temperature of unexposed surface for the domestic intumescent coating system by environmental testing procedure.

  • PDF