Browse > Article
http://dx.doi.org/10.7731/KIFSE.2015.29.5.023

Study on Fire Resistance Performance According to Boundary Conditions for Beams Made of High-Strength Structural Steels Using Analytical Methods  

Kwon, In-Kyu (Department of Fire Protection Engineering, Kangwon National University)
Publication Information
Fire Science and Engineering / v.29, no.5, 2015 , pp. 23-28 More about this Journal
Abstract
Recently, structural materials have been developed to have high performance, and SM 520 has been developed and used for high-rise buildings. However, fires frequently occur in buildings, and the number of victims and amount of damage increase year by year. However, the evaluation of fire resistance performance for structural beams made of SM 520 is done with specimens made of ordinary structural steels with boundary conditions of a fixed beam, and the results are allowed for use in steel-framed buildings. This study analyzed the fire resistance performance of statistically indeterminate beams built with SM 520. The analysis used a fire engineering technique that includes mechanical and thermal data of SM 520 and heat transfer theory, and heat stress analysis was also conducted. The results from the analysis were compared with those from a statistically determinate beam made of ordinary structural steels.
Keywords
High strength steels; SM 520; Fire resistance performance; Fire design;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 BHP Melbourne Research Laboratories, "Open-deck Car Park Fire Tests", Melbourne, Australia (1985).
2 Kawasaki, "Unprotected Steel Frame of Car Park Applied Fire Resistance Steel", Kawasaki, Japan (1996).
3 J. Outinen, J. Kesti and P. Makelainen, "Fire Design Model for Structural Steel S 355 Based on Transient State Tensile Test Results", Journal of Steel Construction Research, Vol. 42, No. 3, pp. 161-169 (1998).
4 J. W. Lee, M. A. Morovat, G. Hu, M. D. Engelhardt and E. M. Taleff, "Experimental Investigation of Mechanical Properties of ASTM A992 Steel at Elevated Temperatures", American Institute of Steel Construction, Vol. 50, No. 4, pp. 249-272 (2013).
5 I. K. Kwon, "Evaluation of Structural Stability for Beams Made of High Strength Structural Steels (SM 570) by Analytic Method", Journal of Korean Institute of Fire Science and Engineering, Vol. 28 No. 3, pp. 49-54 (2014).
6 Swedish Institute of Steel Construction, "Fire Engineering Design of Steel Structures", Stockholm, Sweden (1976).
7 I. K. Kwon, "Introduction of Architectural Engineering", Kyunggi, Korea (2010).
8 Ministry of Construction and Transportation, "Development of Fire Engineering Technique", Gwachenon, Korea (2002).
9 A. H. Buchanan, "Structural Design for Fire Safety", Chichester, England (2000).
10 C. Neves, "The Critical Temperature of Steel Columns with rEstrained Thermal Elongation", Fire Safety Journal, Vol. 24, No. 3, pp. 211-229 (1995).   DOI