• Title/Summary/Keyword: Fire Protection System

Search Result 571, Processing Time 0.022 seconds

A Study on the Fire Protection System in the Stage (공연장의 소방시설 설치기준의 개선방안에 관한 연구)

  • 장상태;이영재
    • Fire Science and Engineering
    • /
    • v.13 no.4
    • /
    • pp.13-19
    • /
    • 1999
  • Currently, conventional fire prevention facility installation standard is based on the use and size of the domestic theaters. In the study, theaters with 1,900 seats were examined to suggest a suitable method to adapt a better fire preventing system. The proposed systems are as follow. - 100% of backup pressed-water outlet device, considering waterproof pressure for fire prevention facility at the top floor. - The supplement of the side wall type header and a large caliber outlet header for stage open sprinkler. - Subdividing a installation rule for special detector and implementing the latestdetector. - Installation of fire curtain for dividing stage area and auditorium area, and also the method of installation of fire curtain.

  • PDF

Study of the Effective Management and Care System on in-Use Fire Fighteris Turnout Gear (소방복 유지관리시스템의 효율화 방안)

  • Son, Bong-Sae;Choi, Kye-Youn
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.72-77
    • /
    • 2011
  • This study aims to provide fundamental information required to establish an efficient maintenance and management system for fire fighting clothing which takes into account the domestic fire protection environment and situation. There aren't any detailed regulations and appropriate pre-inspection systems which would be required for proper maintenance of fire fighting clothing, as well as any test methods to determine the life spans of fire fighting clothing properly. Thus, this study tries to analyze the problems in use of fire fighting clothing and its maintenance situation and summarize overseas maintenance situation for fire fighting clothing. As a result, it is found that domestic fire fighting clothing is washed, repaired, and stored without any systematic management regulations. It is also found that the life spans of fire fighting clothing are determined, based on part of overseas management regulations on fire fighting clothing. Therefore, it is imperative to set up efficient management regulations and test methods for fire fighting clothing which would be required for efficient use of the fire fighting budgets and the life safety of fire fighters.

A study on the implementation of digital anti-fire monitoring system with multipoint communication protocol (다중포인트 통신 프로토콜을 지원하는 디지털 화재 방지 모니터링 시스템 구현에 관한 연구)

  • Kim, Ki-Jung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.6
    • /
    • pp.1423-1428
    • /
    • 2012
  • In this paper, we investigated an implementation of anti-fire monitoring system based on the RS-485 communication to support local area coverage within a range of 1 Km range. We developed a Multi Point Communication Protocol supporting input/output information processing and control up to 8128 terminal check points, which provides an interface between the anti-fire monitoring system receiver and multiplex transponders. Additionally, a multiplex transponders controller has been designed for the implemented system to comply with the government regulation on fire protection, especially to monitor, report and control 1016 terminal check points within the time limit.

A Study on the Development of Fire Extinguishing Agent and Extinguishing System for ESS Fire (ESS 화재전용 소화약제 및 소화시스템 개발에 관한 연구)

  • Lee, Yeon-Ho;Lee, Joo-Hyung;Kim, Soo-Jin;Chon, Sung-Ho;Choi, Byoung-Chul;Oh, Seung-Ju;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.147-155
    • /
    • 2020
  • This paper presents a study on the development of a fire extinguishing agent and extinguishing system for an energy storage system (ESS) fire. The fire extinguishing agent designed to extinguish an ESS fire is a highly permeable fire extinguisher that reduces the surface tension and viscosity while bringing about cooling action. This is the main extinguishing effect of this type of wetting agent, which displays the characteristics of fire extinguishing agents used for penetrating the battery cells inside the ESS module. For the fire extinguishing system, a local application system was designed to suppress fire on a rack-by-rack basis. A 360° rotating nozzle was inserted into the rear hall of the ESS module, and general nozzles were installed in the rack to maximize the fire extinguishing effect. The fire extinguishing agent was strongly discharged by virtue of the gas release pressure. Experiments on fire suppression performance with ESS module 1 unit and module 3 units showed that all visible flames were extinguished in 8 s and 9 s, respectively, by the fire extinguishing agent. In addition, based on confirming reignition for 600 s after the fire extinguishing agent was exhausted, it was confirmed that the ESS fire was completely extinguished without reignition in all fire suppression performance experiments.

Boryeong Fire Plant Museum Project (보령화력발전소 홍보관 계획)

  • Lee, Moo-Sang;Jung, Do-Kuen
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2007.05a
    • /
    • pp.77-78
    • /
    • 2007
  • This project has been designed for people to experience and understand the process, importance and benefit of coal fire plants. As the biggest and first typical Korean fire plant using coal, Boryeong fire plant has had important roll for the Korean industries. Even so, people has had wrong prejudice for the fire plant in terms of environmental protection. To do these kind of rolls, this museum has been designed with theme, "Boryeong fire plant mating symbiotic relationship between nature, human and technologies." The space was zoned with five major themes: i. circulation of energy in nature, ii. electric power and eco-fire plant, iii. future energy, iv roll for future of environment, v. Korea as the leading energy industry. The design has been developed focused on spatial experiences to make 'Design Sequence' with linear circulations haying several important destinations. The interior has been finished with minimal color and materials projected by big sized movie and various LED movie system. Concept of appordance has been used to make interactive experiences between exhibits and visitors.

  • PDF

Predicting on Human-caused Forest Fire Occurrence in South Korea

  • Chae, Hee Mun;Lee, Chan yong
    • Journal of Korean Society of Forest Science
    • /
    • v.95 no.2
    • /
    • pp.160-167
    • /
    • 2006
  • Most of the forest fires that occur in South Korea are caused by human. We partitioned South Korea into nine districts and used observed weather data and daily fire occurrence records for the 1994 to 2003 period to develop a human-caused fire occurrence model of South Korea. Logistic regression analysis techniques were used to relate the probability of a fire day to Fine Fuel Moisture Code (FFMC) component of the Canadian Forest Fire Danger Rating System. The probability of the number of fire day was increased as FFMC increased in the nine districts of South Korea.

A Comparison Study on the System of the cultural properties law for Fire Protection in Korea and Japan (한국과 일본의 제도적 문화재보호에 대한 비교연구)

  • Yun, Yoo-Hyuk;Kim, Dong-Eun;Seo, Dong-Goo;Lee, Jae-Young;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.57-60
    • /
    • 2008
  • A comparative study on the prevention regulation of historical heritage between Korea and Japan. Every years fire accident to historical building is increasing such as Daewoongjun, Naksansa, Namdaemun and so on. The aim of this comparative study is to investigate and compare the prevention regulation in the side of fire safety of historical building between Korea and Japan. This study focus on the background of development and exchange of Fire safety law in Japan because of same condition, building material and prevention regulation.

  • PDF

A Study on the Measures of Fire Protection System of Historic Timber Architecture in Kangwon-Do (강원도지역 중요목조문화재 소방대책에 관한 연구)

  • Koo, Won-Hoi;Jung, Hae-June;Shin, Ho-Joon;Back, Min-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.446-449
    • /
    • 2011
  • 2005년 낙산사 이후 강원도 지역의 목조문화재의 소방대책 및 안전의식의 증대와 함께 많은 소방시설의 보강 및 정비가 이루어 졌다. 그럼에도 2008년 숭례문화재가 발생하는 등 목조 문화재의 손실이 발생하고 있다. 이 논문에서는 강원도에 위치한 중요 목조 문화재를 중심으로 목조 문화재의 소방 시설을 비교하고 삼척시에 위치한 죽서루를 중심으로 소방 현황과 대책에 대해서 알아보고 목조문화재의 화재 예방 및 소방대책에 대하여 제안하고자 한다.

  • PDF

A Study on the Analysis of Operation Reliability of Fire Doors and Fire Shutters Using Fire Statistical Data (화재통계자료를 활용한 방화문, 방화셔터 작동신뢰성 분석에 관한 연구)

  • Jin, Seung-hyeon;Kim, Hye-Won;Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.119-120
    • /
    • 2020
  • In order to establish an evaluation method that can quantitatively evaluate the fire safety of existing buildings in Korea, a stochastic approach is needed to consider the extent of damage in the event of actual fire, along with the operation and installation of facilities. Accordingly, as a basic study for the establishment of fire safety assessment methods for buildings, this study aims to analyze the results of safety inspection and the degree of damage caused by the operation of fire doors and fire shutters in order to derive the reliability of fire doors and fire shutters. As a result, the results of inspection of fire shutters and fire doors and the results of operation using fire statisticians are as follows. As a result of the inspection, the positive rate of fire doors was about 82% and 98% of normal operation was derived from the fire investigation.

  • PDF

Citic Tower Construction Key Technology

  • Xu, Lishan
    • International Journal of High-Rise Buildings
    • /
    • v.8 no.3
    • /
    • pp.185-192
    • /
    • 2019
  • Citic Tower is the first over-500 m-tall super highrise building in the world, located in the high seismic intensity area with paek ground acceleration over 0.2g in 475 years. This project is unique in its complexity, large volume, and challenging site conditions (zero site for construction). The traditional techniques can hardly meet safty, quality and schedule requirements of the construction. This article introduces the key construction technologies that are innovatively developed and applied in Citic Tower project construction, including intelligent super-high-rise building integrated construction platform system, independently developed by the CCTEB; Jump-Lift Elevator, which is the first of the kind with service height over 500 meters; combined temporary-and-permanent fire protection systems. The BIM technology is also applied in this project. Through technical innovation, and utilization of technologies, construction speed and safety had been greatly improved.