• Title/Summary/Keyword: Fire Prevention Administration

Search Result 66, Processing Time 0.02 seconds

A Study on the Systemic Improvement for the Enactment and Revision of the National Fire Safety Code (국가화재안전기준(NFSC)의 제·개정 시스템 개선에 관한 연구)

  • Song, Young-Joo;Kim, Tae-Woo;Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.110-119
    • /
    • 2020
  • The National Fire Safety Code (NFSC) sets forth the installation methods and technical standards of firefighting facilities. This information is stipulated in the attached Table 1 of the Enforcement Decree of the Act on Fire Prevention and Installation, Maintenance and Safety Control of Fire-Fighting Systems. The NFSC serves as a foundation for fire prevention and public safety. However, the current version of the NFSC has been under scrutiny due to its delayed enactment and revision process. This is because of its structural inflexibility, time-consuming procedures, and mixed usage of both performance and technical standards. Furthermore, there are difficulties with keeping its unique specialties due to the absence of a specialized, permanent independent entity that enacts, revises, and maintains its standards. Moreover, the NFSC lacks collectivity, openness, and consistency. Therefore, to overcome the aforementioned obstacles, this study investigates the operational and legal status of the NFSC and the problems regarding its enactment and revision process. Further, it presents suggestions for system improvement by analyzing and comparing the information with domestic and foreign counterparts dedicated to managing their similar technical NFSC standards. First, the study recommends that the legal performance and technical standards mixed within the current NFSC should be separated. Second, the enactment and revision of technical standards should be implemented by the private sector and not by the government. Third, technical standards should adopt a user-oriented approach for the code system.

Fire Service Policy Theory for Establishing Fire Science (소방학의 학문적 정체성 확립을 위한 소방정책론 정립방안)

  • Ryu, Sang-Il;Lee, Jae-Eun
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.2
    • /
    • pp.421-432
    • /
    • 2010
  • In Korea, about 80 academic departments related to fire science are in operation throughout the country, but fire science is not included as a branch science in the science classification system acknowledged by the Ministry of Education, Science and Technology and its position as a science is not solid yet. In response to this problem, research is being made actively to establish fire science recently. This study aims at composing the fire service policy theory which is one of sub areas of fire science. First, the concept of fire service policy should be established, and fire service policies should be divided into different types. In addition, it is necessary to examine the direction of the development of fire service policies in Korea, and the unique characteristics of fire service policies should be described. Next, we will mention fire service policy making and participants, theories on the determinants of fire service policies, the execution of fire service policies, and the evaluation of fire service policies. Particularly, based on the peculiarity of fire service, it is necessary to explain policies on fire prevention and precaution, fire investigation, rescue and first aid, public campaigns for safety and prevention, fire insurance, etc. Finally, we suggest the future directions of fire service policies according to the change of environment in the future.

Methods to Improve the Design of Household Fire Extinguishers through an Empirical Analysis of Consumer Compatibility (소비자의 적합성 실증분석을 통한 가정용 소화기의 디자인 개선방안)

  • Lee, Sung-Woo
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.58-66
    • /
    • 2020
  • Households are categorized as exceptions in the Fire Services Act; oftentimes, the 'Golden Time' is missed at the early stages of a fire, resulting in loss of life. As such, due to the high number of deaths caused by household fires, the Korean government amended the Fire Services Act to make it mandatory for all detached houses to be equipped with a fire extinguisher from 2017 onwards. Only 34.8% of households were properly equipped with a fire extinguisher, according to the 2018 factual survey on fire extinguishing facilities in households conducted by the Fire Department. Fire extinguishers are crucial in case of fire but many households avoid them because they are red and have a rough aesthetic, which does not suit the household environment. There is now a need for diverse simple fire extinguisher designs so that they can be used as interior décor in the household in the day-to-day while being available for putting out a fire when necessary. If fire extinguishers have designs that go well with any household space like other decorative ornaments, this will greatly increase consumers' motivation to purchase them. It is greatly anticipated that various companies will work on developing designs for fire extinguishers to commercialize them for households in the future.

Development of Safety Equipment Database for Effective Management in Wooden Cultural Heritage (효율적 목조 문화재 방재관리를 위한 방재설비 데이터베이스구축)

  • Kim, Donghyun;Lee, Ji-hee;Yi, Myungsun
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.46-53
    • /
    • 2016
  • Wooden cultural heritage is vulnerable to fire, flooding and other hazards. Therefore, an effective disaster prevention and mitigation strategy for them should include preventive measures in a full range of management. These were used to construct a disaster safety system for 508 wooden cultural heritage items by the Cultural Heritage Administration. According to the type of ownership and administration, national and public heritage is controlled by personal management or commissional management. Among them, it is arranged with the safety security institute for important cultural properties. In addition, they have problems of field management with no computerization about the management information for a disaster facility system. Therefore, this study aimed to develop a DB platform that can share information with many users who need to manage cultural heritage. Through a field survey, it is feasible to develop a disaster facility system to provide the information, such as the main data, quantity and location.

A Study on Factors Influencing Fire Service Power - An Analysis of the Fundamental Variable for Fire Service Budget - (소방력에 영향을 미치는 요인에 관한 연구 - 소방예산의 기본변수분석을 중심으로 -)

  • Kim, Jin-Dong
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.9-19
    • /
    • 2008
  • Recently the systematic change in the fire and disaster prevention administration, which was less studied than other administrative systems, has been in progress. In particular, the fire service demands are increasing and forms are diversified. The first thing you must do is to make up the fire service power according to the fire service demands. Such an allocation results in social welfare satisfaction. The purpose of this study is to investigate the determinants of fire service force. And this study investigates that fire service demand is affected by socioeconomic factor. To do this, this study reviews fire service force, the fire service demand, socioeconomic factor and financial factor. And this study sets up four hypotheses based on the theoretical backgrounds and the past research. The statistical method used for the verification of hypotheses are multiple regression analysis and structural equitation analysis. The analysis showed that fire service demand and financial factor were positive significant variable for fire service power. But socioeconomic factor was a negative significant variable. Also the analysis showed that social factor was a positive significant variable and economic factor was a negative significant variable for fire service demand.

Assessment of Fire Risk Rating for Wood Species in Fire Event (화재 발생 시 목재 수종의 화재위험성 등급 평가)

  • Jin, Eui;Chung, Yeong-Jin
    • Applied Chemistry for Engineering
    • /
    • v.32 no.4
    • /
    • pp.423-430
    • /
    • 2021
  • In order to evaluate the fire risk and fire risk rating of wood for construction materials, this study focused on fire performance index-III (FPI-III), fire growth index-III (FGI-III), and fire risk index-IV (FRI-IV) according to Chung's equations-III and -IV. Western red cedar, needle fir, ash, and maple were used as the specimens. The fire characteristics were investigated using a cone calorimeter (ISO 5660-1) equipment on the specimen. The FPI-III measured after the combustion reaction was 0.86 to 12.77 based on polymethylmethacrylate (PMMA). The FGI-III was found to be 0.63 to 5.26 based on PMMA. The fire rating according to the FRI-IV, which is the fire rating index, was 0.05 to 6.12, and the western red cedar was 122.4 times higher than that of the maple. The fire risk rating according to the FRI-IV increased in the order of maple, ash, needle fir, PMMA and western red cedar. The CO peak concentration of all specimens was measured as 103 to 162 ppm, and it was 2.1 to 3.2 times higher than 50 ppm, the permissible exposure limits of the US occupational safety and health administration. Materials such as western red cedar, which have a low bulk density and contain a large amount of volatile organic substances, have a low FPI-III and a high FGI-III, so they have a high fire risk rating.

The Study for Fire Prevention of Main Wooden Cultural Properties of Korea (국가지정 목조문화재의 소방대책에 관한 실태조사)

  • Back, Min-Ho;Lee, Ji-Hyang
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.1-8
    • /
    • 2010
  • This study is searched in the on actual condition and analysis about the fire fighting measure of 123 main wooden cultural properties designated by the Cultural Heritage Administration. First, the management of wooden cultural properties and the present condition of fire occurrence are arranged. Second, The field research and the information research of related government agencies are done from August. 2008 to October. 2008 about 123 main wooden cultural properties: Cultural properties designation classification, location classification, building area, number of possession cultural properties, present condition of fire fighting, a fire engine drive direction for fire suppression, number of self-defense fire brigade, fire administrator nomination, and the distance and time from a fire station are arranged in this study. Third, the inside and outside present conditions are classified and analyzed by average index for the fire occurrence risk of 123 main wooden cultural properties. And the basic data is arranged for the fire fighting measure of main wooden cultural properties.

The Impact of the Government's Earthquake Disaster Response Capabilities and the Legal and Institutional Appropriateness of the Disaster Management System on the Operational Performance of Disaster Management : Focused on Fire Officer's Consciousness (정부의 지진재난 대응역량과 재난관리체계의 법·제도적 적절성이 재난관리 운영성과에 미치는 영향 : 소방공무원의 인식을 중심으로)

  • Youn, SeokMin
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.318-330
    • /
    • 2020
  • Purpose: In this study, the effect of the government's disaster response capabilities and the legal and institutional appropriateness of the disaster management system on the operational performance of disaster management performance were verified. Method: Questionnaire survey was performed for the fire officials, and the surveyed data was statistically analyzed by using SPSS 25.0 program. Result: The main results of this study are as follows. First, the government's earthquake disaster response capability is found to have a significant effect on disaster follow-up management as well as disaster prevention preparation, which is a factor in disaster management performance. Second, it has been shown that the legal and institutional appropriateness of the earthquake disaster management system has a significant impact on disaster follow-up management as well as disaster prevention preparation, which is a factor of disaster management performance. Conclusion: The important policy implications for improving the operation performance of disaster management could be obtained in preparation for earthquakes in Korea.

A Qualitative Study on the Fire Officials Inter Integrity (소방공무원의 내부청렴도에 관한 질적 연구)

  • Chae, Jin;Woo, Seong-Cheon
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.107-114
    • /
    • 2010
  • Corruption in public offices can lead to corruption in overall society. Moreover, it can also result in steady growth of social expense caused by distrust in direct public relations of civil society administration. In order to devise a more comprehensive measure against corruption, it is essential to evaluate internal organization. This study suggests a scheme for improvement on fire officers' inter integrity, researched by in-depth interview. According to the study, there are numerous conventional corporate cultures remaining in the organization which fire officers are mutually trying to create reasonable and democratic corporate cultures. Furthermore, it was found out that structural issues of the organization, such as guaranteed anonymity of corruption prevention system, closed budget, et cetera, are the mostly dissatisfactory factors other than individual matters of the organizational members.

Assessment of Smoke Risk of Combustible Materials in Fire (화재 시 가연성 물질의 연기 위험성 평가)

  • Chung, Yeong-Jin;Jin, Eui
    • Applied Chemistry for Engineering
    • /
    • v.31 no.3
    • /
    • pp.277-283
    • /
    • 2020
  • The smoke hazard assessment of building materials focusing on smoke performance index-II (SPI-II) and smoke growth index-II (SGI-II) was investigated. The test species used were Japanese cedar, spruce, lauan, and red pine. The smoke characteristics of wood specimen were investigated using a cone calorimeter (ISO 5660-1). SPI-II was measured after the combustion reaction increased by 1.31~2.15 times based on red pine. The fire risk by SPI-II increased in the order of spruce, lauan, Japanese ceda, and red pine. SGI-II increased by 1.18~2.55 times compared to that of Japnese ceda. The fire risk caused by SGI-II increased in the order of Japanese ceda, spruce, lauan, and red pine. COmean concentrations were ranged from 58 to 133 ppm, which was higher than permissible exposure limits of the occupational safety and health administration (OSHA), 50 ppm. Therefore, woods such as red pine containing various volatile organic substances, were considered to be highly smoke hazardous due to low SPI-II and high SGI-II.