• Title/Summary/Keyword: Fire Module

Search Result 149, Processing Time 0.028 seconds

Case Study of S2 Service Response Guidance in case of Passenger Ship H Abnormal Condition (여객선 H호 선내이상 알람 발생시 대응가이던스 사례연구)

  • Yoo, Yun-Ja;Song, Chae-Uk;Yea, Byeong-Deok
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2018.05a
    • /
    • pp.45-46
    • /
    • 2018
  • S2 module, which is one of the Korean type e-Navigation services, is a service concept that monitors the situation onboard and provides an emergency level determination and response guidance to the ship when an alarm occurs. S2 module is divided into fire/ seakeeping / navigation safety sub-module. In this paper, the concept of S2 service based on actual ship is explained through the response guidance case study of navigation safety module in case of abnormal condition in the passenger ship H.

  • PDF

Development of a Single Fire Alarm System of House Based on Wireless Communication (무선 감응식 주택 단독 화재 경보 시스템 개발)

  • Park, Hyeon-Ho;Cho, Seong-Jin;Park, Byeong-Hwa;Heo, Jeong-Hun;Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.5
    • /
    • pp.1017-1022
    • /
    • 2018
  • In this paper, a single house fire alarm device, which can solve the problem of fire perception at midnight time and the attenuation of alarm signal due to the wall between rooms based on the wireless communication, was developed. The radio controlled fire alarm device was designed to allow fire to be recognized quickly and accurately by monitoring the temperature and $CO_2$ concentration based on the temperature sensor and gas sensor, by detecting the fire in the house and by transmitting the fire alarm to the individual wireless alarms of other rooms using the wireless transmission/reception module. Using the Arduino as a main control device, three independent fire alarm device prototypes were made, and their usefulness was verified by the correct operations in temperature and gas tests.

Overview of Fire Safety onboard International Space Station(ISS): Characteristics of Flame Ignition, Shape, Spread, and Extinction in Microgravity (국제우주정거장 화재안전 연구개괄: 마이크로중력화염의 특성(점화/형상/전파/소멸특성))

  • Park, Seul-Hyun;Hwang, Cheol-Hong
    • Journal of the Korean Society of Combustion
    • /
    • v.17 no.4
    • /
    • pp.21-29
    • /
    • 2012
  • Due to a significant leap in the science and technology, the manned space exploration that has started with suborbital flights is now being expanded into the deep space. The space superpowers such as the U.S. and Russia have been making an effort to further develop the manned space technology. Among such technologies, the fire safety technology in microgravity has recolonized as one of the most critical factors that must be considered for the manned space mission design since the realistic fire broke out onboard the Mir station in 1997. In the present study, the flame characteristics such as flame ignition, shape, spread, and extinction that are critical to understand the fire behavior under microgravity conditions are described and discussed. The absence of buoyancy in microgravity dominates the mass transport driven by diffusiophoretic and thermophorectic fluxes (that are negligible in normal gravity) and influences the overall flame characteristics-flame ignition, shape, spread, and extinction. In addition, the cabin environments of the pressurized module (PM) including the oxygen concentration, ambient pressure, and ventilation flow(which are always coupled with microgravity condition during the ISS operation) are found to be the most important aspects in characterizing the fire behavior in microgravity.

Development of K-Maryblyt for Fire Blight Control in Apple and Pear Trees in Korea

  • Mun-Il Ahn;Hyeon-Ji Yang;Sung-Chul Yun
    • The Plant Pathology Journal
    • /
    • v.40 no.3
    • /
    • pp.290-298
    • /
    • 2024
  • K-Maryblyt has been developed for the effective control of secondary fire blight infections on blossoms and the elimination of primary inoculum sources from cankers and newly emerged shoots early in the season for both apple and pear trees. This model facilitates the precise determination of the blossom infection timing and identification of primary inoculum sources, akin to Maryblyt, predicting flower infections and the appearance of symptoms on various plant parts, including cankers, blossoms, and shoots. Nevertheless, K-Maryblyt has undergone significant improvements: Integration of Phenology Models for both apple and pear trees, Adoption of observed or predicted hourly temperatures for Epiphytic Infection Potential (EIP) calculation, incorporation of adjusted equations resulting in reduced mean error with 10.08 degree-hours (DH) for apple and 9.28 DH for pear, introduction of a relative humidity variable for pear EIP calculation, and adaptation of modified degree-day calculation methods for expected symptoms. Since the transition to a model-based control policy in 2022, the system has disseminated 158,440 messages related to blossom control and symptom prediction to farmers and professional managers in its inaugural year. Furthermore, the system has been refined to include control messages that account for the mechanism of action of pesticides distributed to farmers in specific counties, considering flower opening conditions and weather suitability for spraying. Operating as a pivotal module within the Fire Blight Forecasting Information System (FBcastS), K-Maryblyt plays a crucial role in providing essential fire blight information to farmers, professional managers, and policymakers.

Development of Multi-purpose Smart Sensor Using Presence Sensor (재실 감지 센서를 이용한 다용도 스마트 센서 개발)

  • Cha, Joo-Heon;Yong, Heong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.1
    • /
    • pp.103-109
    • /
    • 2015
  • This paper introduces a multi-purpose smart fusion sensor. Normally, this type of sensor can contribute to energy savings specifically related to lighting and heating/air conditioning systems by detecting individuals in an office building. If a fire occurs, the sensor can provide information regarding the presence and location of residents in the building to a management center. The system consists of four sensors: a thermopile sensor for detecting heat energy, an ultrasonic sensor for measuring the distance of objects from the sensor, a fire detection sensor, and a passive infrared sensor for detecting temperature change. The system has a wireless communication module to provide the management center with control information for lighting and heating/air conditioning systems. We have also demonstrated the usefulness of the proposed system by applying it to a real environment.

The devepoement of a raid and fire preventable system using the Zigbee communication and multi-sensor (ZigBee 통신 및 다중센서를 이용한 방범.방재 시스템 개발)

  • Han, Young-Oh
    • Journal of the Korea Computer Industry Society
    • /
    • v.10 no.5
    • /
    • pp.193-200
    • /
    • 2009
  • In this paper, the raid and fire preventable system using Zibee module with IEEE 802.15.4 wireless communication standard and multi-sensor was developed displaying raid and firing condition with wireless network. The raid preventable system is designed using a ultrasonhe waves sensor and infrared sensor. The fire preventable system is designed using a thermistor. The datas for raid and firing condition are communicated from enddevice to coordinator with wireless network and are displayed on PC monitor.

  • PDF

Study on the Explosion and Fire Risks of Lithium Batteries Due to High Temperature and Short Circuit Current (고온 및 단락전류에 따른 리튬배터리의 폭발 및 화재 위험성에 관한 연구)

  • Sim, Sang-Bo;Lee, Chun-Ha;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.114-122
    • /
    • 2016
  • This study is to analyze the explosion and fire risks due to high temperature and short circuit current of Lithium batteries. This study selected the typical types of Li-polymer batteries and Li-ion batteries as the test samples. The result of explosion risk assessment due to the high temperature showed that, while a Li-polymer battery had $170^{\circ}C$ explosion on average, a Li-ion battery had $187^{\circ}C$ explosion. The measurement result of temperature increase due to short circuit current revealed that, in case that protection circuit module (PCM) was normally working, there was little of temperature increase due to over-current limitation. However, in case that PCM was out of order, the temperature of a Li-polymer battery increased up to an average of $115.7^{\circ}C$ and the temperature of a Li-ion battery increased up to an average of $80.5^{\circ}C$, which showed the higher risks of fire and burn.

A Study on the Identification Technique and Prevention of Combustion Diffusion through ESS (Energy Storage System) Battery Fire Case (ESS (에너지 저장장치) 배터리 화재사례를 통한 감식기법 및 연소 확산방지에 관한 연구)

  • Lee, Jung-Il
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.383-391
    • /
    • 2020
  • Purpose: To identify internal self ignition and ignition caused by external flames in energy storage rooms, and to analyze the difference between ignition due to overheating and ignition caused by external heat sources. Method: membrane melting point measurement, battery external hydrothermal experiment, battery overcharge experiment, comparative analysis of electrode plate during combustion by overcharge and external heat, overcharge combustion characteristics, external hydrothermal fire combustion characteristics, 3.4 (electrode plate comparison) / 3.5 (overcharge) /3.6 (external sequence) analysis experiment. Result: Since the temperature difference was very different depending on the position of the sensor until the fire occurred, it is judged that two temperature sensors per module are not enough to prevent the fire through temperature control in advance. Conclusion: The short circuit acts as an ignition source and ignites the mixed gas, causing a gas explosion. The electrode breaks finely due to the explosion pressure, and the powder-like lithium oxide is sparked like a firecracker by the flame reaction.

A Development on Universal RF based Module for Wireless Network (계측 시스템의 무선통신을 위한 RF모듈 개발)

  • Park, Suk-Hyun;Shim, Woo-Hyuk;Seo, Young-Jo;Kim, Beung-Jin;Jeon, Hee-Jong
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3064-3066
    • /
    • 1999
  • The existing equipment with wire communication can expect the stability of data transmission. However, according to increasing a number of DTE (Data Terminal Equipment), wiring work becomes a heavy burden. Restriction to application about portable DTE and the lack of flexibility are another drawback of wire communication. This paper presents the design and implementation of a RF (Radio Frequency) based wireless communication system. The RF based module is designed to the multi communication between DTEs. The RF based module consists of RF circuit and microprocessor. The main properties of RF circuit are maximum 5Kbps transmission rate, maximum 90m transmission distance and 433MHz frequency band. The microprocessor rearrange the data into AHDLC(Advanced High level Data Link Control) format and then instructs RF circuits to transmit/receive the data. The RF module have a wide application field such as fire/security alarm, remote control/measurement etc..

  • PDF

A study of high-efficiency rotating condensing hybrid solar LED street light module system (고효율 회전 집광형 하이브리드 태양광 LED 가로등 모듈 시스템 연구)

  • Min, Kyung-Ho;Jeon, Yong-Han
    • Design & Manufacturing
    • /
    • v.15 no.3
    • /
    • pp.50-55
    • /
    • 2021
  • Solar power generation, which is one of the methods of using solar energy, has a high possibility of practical implementation compared to other renewable energy power generation, and it has the characteristic that it can generate as much power as needed in necessary places. In addition, maintenance is easy, unmanned operation is possible, and power management can be performed more efficiently if operated in a hybrid method with existing electric energy. Therefore, in this study, numerical analysis using a computer program was performed to analyze the efficient operation and performance improvement of solar energy of the rotating condensing type solar LED street lamp. As a result, the two-axis tracking type could obtain 15.23 % more electricity per year than the fixed type, and additional auxiliary power generation was required for the fixed type by 19 % per year than the tracking type. As a result of computational fluid dynamics(CFD) simulation for PV module surface temperature prediction, the The surface temperature of the Photovoltaics(PV) module incident surface was predicted to be about 10℃ higher than that of the fixed type.