• Title/Summary/Keyword: Fire Module

Search Result 149, Processing Time 0.027 seconds

Implementation of Intelligent Home Service Robot Using Wireless Internet Platform (무선인터넷 플랫폼을 이용한 지능형 홈서비스 로봇의 구현)

  • Kim, jin-hwan;Kim, dong-gyu;Son, ki-young;Shin, dong-suk
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2007.11a
    • /
    • pp.201-205
    • /
    • 2007
  • This thesis aims to realize an intelligent home service robot that alerts the user to dangerous situations such as fires and gas leaks by utilizing wireless internet platforms in a cellular phone. The intelligent home service robot is composed of the following parts: The robot part consists of a gas sensor, a fire detector, a smoke sensor, ultrasonic sensors, motors, a camera and a Blue-tooth module and perceives various danger circumstances; The middleware part connects the robot part with the mobile part through the middleware applications, monitors the robot and notifies an emergency situation using SMS modules; The mobile part communicates with the middleware using TCP/IP protocol and controls the robot through various commands; The proposed scheme is to control the sensors of the robot part through and Atmega128 processor, and the mobile part was developed based on the WIPI platform. The robot and middleware parts will be installed in the household, and will be controled by mobile part from the outside.

  • PDF

Implementation of Leakage Monitoring System Using ZigBee (ZigBee를 적용한 누전상태 모니터링시스템 구현)

  • Ju, Jae-han;Na, Seung-kwon
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.1
    • /
    • pp.107-112
    • /
    • 2017
  • In recent years, electric shock accidents due to electric leakage currents of household appliances such as computers, TVs, refrigerators, and LED lights are continuously occurring in homes and industrial buildings. And it is not easy to check the leakage current of each household appliances connected in parallel at the rear end of the module. In addition, the leakage current flowing through the path of the normal current other than the existing current leakage circuit breakers are installed in the distribution box, only the function to cut off the power when the leakage. Therefore, there are various disasters such as electric shock and fire caused by short circuit of household appliances, and the risk of such leakage current is seriously presented. In this paper, we propose a method to implement a leakage monitoring system that can be monitored at all times using Zigbee communication based on IEEE 80215.4, which has advantages in low power and low cost among short range wireless communication systems.

The implementation of liquefaction equipment monitoring system based on Android (안드로이드 기반의 유증기 액화장치 모니터링 시스템 구현)

  • Park, Man-Kyu;Tack, Han-Ho;Kim, Gwan-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.3
    • /
    • pp.583-589
    • /
    • 2016
  • Volatile organic compounds(VOCs) are regarded as a harmful cause substance not only causing air pollutions but also causing global warming phenomenon. For this reason, VOCs are managed politically to reduce emissions by each country. In particular, the vapor from the gas station contains VOCs which is harmful to the human body such as carcinogens benzene and pollute the atmosphere, the Ministry of Environment defined every gas station must install vapor recovery equipment to recover volatile organic compounds. Recently, there are many accidents caused by existing vapor treatment methods, the liquefaction recovery technology is getting the spotlight to cool the vapor at the field. However, because the liquefaction recovery technology have risks of fire or explosion in accordance with temperature, the real time monitoring is critical factor. In this paper, we implement an Android-based monitoring application for liquified vapor recovery device which attached sensor module for temperature and power to monitoring real time information.

A Study of Evaluation Certification on Electronic Power u-IT Convergence Equipment (전력 u-IT 융복합화 기기의 평가와 인증 연구)

  • Yi, Jeong-Hoon;Park, Dea-Woo;Kim, Eung-Sik;Kim, Hong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.11
    • /
    • pp.2433-2440
    • /
    • 2009
  • Whole system and network for supply of electric power and electricity safety are essential element. Electricity safety technology need rating for product and research about certification as product development that is done electric power u-IT cotton flannel mixed with development of u-IT, u-City base technology consists. Study on serve to develop electricity safety integration supervision system to apply product to u-City electric power appliance and cotton flannel mixed of u-IT appliance, Connection badness sensing instrument made device built-in electric power u-IT cotton flannel mixed in outlet that is used most in electric power appliance terminal. Using sensor on ZigBee, RFID performance estimation of communication module about function of product for remote safety check of electricity safety integration supervision system. A performance experiment and estimation in electric leakage, high voltage, Arc, fire detection diagnosis system and certification KS, electricity safety about product that get fitness finding.

A Study on the Design of IoT-based Thermal Sensor and Video Sensor Integrated Surveillance Equipment (IoT 기반 열상 센서와 영상 센서 일체형 감시 장비 설계에 관한 연구)

  • Lee, Yun-Min;Shin, Jin-Seob
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.6
    • /
    • pp.9-13
    • /
    • 2019
  • In this paper, IoT based thermal sensor data and image sensor integrated environmental monitoring system for ship, and it is the monitoring system which can process and transmit the Full HD IP camera image and thermal data transmitted from the thermal module for processing and transmitting, and the viewer S/W is to be developed which provides in real time the information for actual surrounding temperature together with the image, and enables fire prediction which was impossible in the case of the existing equipment by estimating the temperature change as the thermal image is added to the image camera, and saves and analyzes all data while receiving the temperature data and image signal transmitted from the integrated thermal sensor environmental monitoring equipment for ship and displaying them as 2D on the monitoring system.

Structural Performance Evaluation for Composite Beam Member of Hybrid Modules Frame with Steel-Precast Concrete (강-PC 복합모듈러 골조의 합성보에 대한 구조성능 평가)

  • Lee, Sang Sup;Park, Keum Sung;Bae, Kyu Woong;Choi, Yoon Chul
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.5
    • /
    • pp.331-340
    • /
    • 2017
  • This study was performed in order to develop of the new modular construction system. For the modular construction method that is currently applied in the country, it is very expensive in terms of material costs and fire resistance because it uses only the steel C-type beam. In order to overcome this, and the practical application of new steel-PC hybrid module construction system. Improvement and development of the cross-section of the structural beam member in order to be carried out first. An experiment was carried out by making three specimens. Experiment result, the composite beam was dominated by the horizontal shear failure. It was evaluated through a nonlinear analysis and experimental & theoretical for the structural performance the composite beam member.

Implementation of a WIPI-based Intelligent Home Service Robot (WIPI 기반의 지능형 홈서비스 로봇의 구현)

  • Kim, Jin-Hwan;Shin, Dong-Suk
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.5
    • /
    • pp.19-28
    • /
    • 2008
  • In this paper, we implemented an intelligent home service robot system which alerts users to danger by wireless internet platforms for interoperability(WIPI) of a cellular phone. This paper discusses the three parts of the system: robot, middleware and mobile system. First, the robot consists of a gas sensor, a fire detector, ultrasonic sensors, motors, a camera and a Bluetooth module. The robot perceives various danger circumstances. Second, the middleware connects the robot and the mobile system. It monitors the robot and sends emergency notification SMS message to the user's cellular phone if in danger. Third, the mobile system sends commands which control the robot using TCP/IP protocol. The proposed scheme is to control the sensors of the robot part through Atmega 128 processor, and the robot and middleware parts will be installed in the household, and will be controled by mobile part from the outside.

Analysis of GIS Function of Integrated Management Platform for the u-City Service (u-City 서비스를 위한 통합운영플랫폼의 GIS 기능 분석)

  • Kang, Joon-Mook;Seo, Dong-Seob;Baik, Song-Hoon;Seo, Myung-Woo;Park, Joon-Kyu
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.26 no.6
    • /
    • pp.571-581
    • /
    • 2008
  • With the advent of u-City(ubiquitous city) concept, the importance of urban management has been increased. GIS is a foundation for the efficient urban management and an essential technology for the development of u-City. u-City, which aims for convenient, safe, healthy, and comfortable life, provides diverse services based on advanced information technologies, and it will offer more services in the future. u-City integrated management platform enables the ease of service development, guarantees the quality of services for the resident, and provides organic information sharing. Moreover, the platform by integrating GIS and other common management functions, makes possible efficient urban management. In this paper, required functions of u-City integrated management platform for u-City service were analyzed. As a result, GIS module for management of street lights and supervision of fire was developed and the application usability of u-City integrated management platform was verified by service simulation.

Design and Implementation of LoRa-based Emergency Exit Guide System (LoRa 기반 피난 유도 체계의 설계 및 구현)

  • Shin, Jaejun;Eun, Seongbae;So, Sun-Sup;Kim, Byungho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.4
    • /
    • pp.569-574
    • /
    • 2018
  • This paper proposes and implements a LoRa-based emergency exit guide system which can direct the optimal refuge path accounting for the real state of the fires. Each 4-way emergency exit guide sign presents a right direction through one of four LED signs toward the possible exit dynamically calculated by the shortest path algorithm. We constructed a simulation environment with 8 spots of the emergency exit guide signs and 2 exits, which can simulate variant cases of fire accidents, and showed that the proposed algorithm can presents the right guidance for each emergency exit guide sign. We also evaluated the performances of LoRa-based wireless communications using a self developed communication module in the various indoor and outdoor environments. The proposed system can be applied to small and medium sized buildings as well as larger ones in terms of cost efficiency, in which there's no needs to invest for the complex equipments except only sensors and emergency exit guide signs.

Development of M2M-based Underground Space (subway) Disaster Response Network and EL Display Integrated Board (M2M기반 지하공간(지하철) 재난대응 네트워크 및 EL 디스플레이 통합 보드 개발)

  • Park, Miyun;Kwon, Segon;Park, EunChurn;Lee, Jeonhun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.4
    • /
    • pp.422-441
    • /
    • 2017
  • Notifying emergency evacuation methods, accurate disaster location and evacuation route guidance can be very active alternatives to quickly minimize evacuation and casualties in disaster situation in the development of subway disaster prevention detection system that detects the disaster signs at the subway station early on the basis of Internet of things and leads passengers to evacuate. It's not easy to ensure perfect functioning of fire fighting facilities and equipments due to underground space structure with narrow exits. Therefore, we developed disaster provision EL Display integrated board that can induce the most efficient evacuation and the field experiment was conducted to examine the practical application in this study. Especially the applicability was verified by field application test because there is no case in which EL panels are used to evacuate disasters.