도금 공장의 화재 예방을 위한 도금장비 개선에 관한 연구 (A Study on improvement of plating equipment for fire prevention)

  • 김성재;김성곤;유우식
    • 대한안전경영과학회지
    • /
    • 제19권4호
    • /
    • pp.35-42
    • /
    • 2017
  • A number of plating companies have been exposed to the risk of fire due to unexpected temperature increasing of water or other reasons in a plating bath. Since the companies are not able to forecast the unexpected temperature increasing of plating bath and most of raw materials in the bath have low ignition temperature, it is easy to be exposed to the risk of fire. Thus, in previous study, we tried to monitor and notice the dangerous change of temperature of water immediately to prevent the risk of fire from plating process. However, unfortunately previous studies were not able to shut out the fundamental cause of fire since bath temperature sensor can detect air temperature when the level sensor was malfunctioned. In this paper we developed the Teflon heater which contains a built in temperature sensor and improved plating equipment system. Teflon heater is improved using Pt $100{\Omega}$ sensor which can detect until $600^{\circ}C$. When the bath temperature sensor detects over $60^{\circ}C$ or the Teflon heater sensor detects over $240^{\circ}C$ they temporarily shut down the heater to control temperature. Also relay completely shuts down main power when detects instant temperature is detected over 5% of $240^{\circ}C$ by the heater sensor to prevent teflon melting down and fire spreads. Developed plating equipment system can monitor a real time temperature in the teflon tube and bath water. Therefore we think the proposed plating equipment can eliminate the possibility of fire in plating processes fundamentally.

법과 제도적 관점에서 본 소방특별조사의 개선방안 (A Study on The Improvement of the Leagal Study on Special Fire Safety Inspection System)

  • 이재욱;정기성
    • 문화기술의 융합
    • /
    • 제7권3호
    • /
    • pp.545-552
    • /
    • 2021
  • 2011년 8월 4일에 개정된 법률에 따라 소방특별조사는 소방시설의 유지·관리 등을 관계인(소유자·관리자·점유자)이 하고 이에 대한 책임도 관계인에게 주어졌다. 소방특별조사는 기존의 모든 소방대상물에 직접 출입하여 소방시설의 유지·관리 상태 등을 조사하는 대신에 매년 일부 대상물을 선별하여 방문하고 소방시설의 유지·관리 상태 등을 확인하고 잘못된 부분에 대하여 시정하고 그 책임에 대하여 과태료 등의 처분을 하는 것이다. 이 제도를 도입한 이유가 관계자의 책임을 강화하여 민간자율정정제도의 정착, 소방전문 인력의 부족, 빈번한 대민접촉에 따른 부패의 개연성과 소방검사에 따른 소방기관의 책임 등이 고려되었다. 그러나 소방특별조사제도를 도입하여서도 여러 가지 문제가 대두되고 있다. 소방안전을 위한 제도 중 하나인 소방특별조사는 관계 법령에 따라 소방대상물에 설치된 소방시설에 대하여 적합하게 설치·유지·관리되고 있는지를 관계 공무원, 특히 소방공무원이 확인하는 것이다. 소방특별조사는 1958년 소방법이 제정된 당시에 소방검사로 도입되어 최근까지 30여 차례의 개정과정을 거쳐, 현행 소방특별조사는 2003년 기존의 소방법체계가 4개의 법률로 분법화되면서 "화재예방, 소방시설 설치·유지 및 안전관리에 관한 법률"로 기존의 소방검사 소방특별조사로 변경되어 수용되었다.

화학물질 취급시설의 안전관리 합리화 방안 연구: 건축물 내화기준 중심 (A study on the Rationalization of Safety Management in Chemical Facilities: Focused on Architecture Fire Resistance Standards)

  • 이은별;유병태
    • 한국화재소방학회논문지
    • /
    • 제33권3호
    • /
    • pp.91-97
    • /
    • 2019
  • 국내 화학물질 안전관리는 환경부의 화학물질관리법이 기본이 되어 관리되고 있다. 그 중에서도 취급시설의 설치 및 관리기준을 강화하여 관리하고 있는데, 타 법과의 상충, 시설 규모 및 물질 특성 미반영 등으로 인한 문제점들이 노출되었다. 본 연구에서는 이러한 취급시설 기준 중 건축물 내화기준에 대해 보다 현실적이면서 합리적인 개선 방안을 마련하고자 하였다. 이를 위해 국내 유사 화학물질 취급시설 안전관리 법령의 건축물 내화기준을 비교하였으며, 환경부 화학물질안전원 국민신문고를 통해 접수된 취급시설 기준 관련 민원 2220건 중 대표 민원 사례를 통해 주요 문제점을 파악하였다. 마지막으로 화학물질관리법상 취급시설의 규모와 물질의 종류를 구체화하여 건축물 내화기준을 적용하는 개선 방안을 제시하였다. 향후, 본 연구 결과는 환경 유해성을 고려한 화학물질관리법의 기본 취지에 부합하고, 산업계에도 현실적으로 적용될 수 있는 합리적인 기준마련에 기여할 수 있을 것으로 기대된다.

건축물 제배연시나리오 작성을 위한 구획실 발열특성 연구 (Study on Characteristics of Heat Release Rate in Compartment of Building for Scenario of Smoke Management)

  • 김정엽;신현준
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.398-403
    • /
    • 2009
  • The theoretical bases on characteristics of heat release rate in compartment of building for scenario of smoke management are introduced and the numerical applications to simple compartment model are carried out. The growth stage which is important for smoke management design is modelled as t-squared fire curve including fire growth coefficient with related to growth rate. The conditions for the happening of flashover is presented such as $600^{\circ}C$ of temperature or $20kW/m^2$ of radiation heat flux. After the flashover happen, the fire in compartment changes to fully developed fire having the characteristics of ventilation-controlled fire. As the result of numerical analysis to simple compartment model, the time to reach 900K under ceiling for condition of medium growth is twice for condition of fast growth.

  • PDF

태양광 발전 시스템의 화재 위험 감소 방안에 관한 이론적 연구 (Study on Theoretical Research to Reduce Fire Risk of Solar Power System)

  • 박경진;이근출;이봉우
    • 한국산업융합학회 논문집
    • /
    • 제23권2_2호
    • /
    • pp.219-224
    • /
    • 2020
  • This study is based on the principle of solar power system and fire breakout. The result of the survey indicates that a solar power system is vulnerable to fire due to lack of maintenance after the installation. Currently the national fire safety agency does not have standards and legal provisions for the installation and maintenance of solar power facilities. Therefore, it increases the risk of fire breakouts as well as possibility of electric shock for the firefighters during fire fighting. This results possible damages to the human and equipments. In this study is proposing an automatic fire extinguishing system to reduce the power generation of solar panels during fire breakouts. Also, propose an over load current alarm system and fire prevention measures for fire fighters. The results of this study will be used as basic data for further fire testing of solar power systems.

목조 문화재 건축물의 화재 방재를 위한 조사 연구 (A Study on the Methods of Fire-Safety in Cultural Property Wooden Buildings)

  • 장형순;조원석;김흥기
    • 한국농촌건축학회논문집
    • /
    • 제10권4호
    • /
    • pp.25-32
    • /
    • 2008
  • The prevention of disasters in cultural property is very important management and historical duties. The reason can't be measured values with monetary scale of our contemporary. Therefore, this paper was considered fire-safety as one of terrible threat-disasters about the wooden buildings. This research deal with 47 cases cultural property wooden building by whole investigation(field survey and interview) in Gangnung province. The most buildings have basic fire extinguisher; ABC powder. A few buildings are rarely installed fire extinguishing equipments; outdoor fire hydrant, heat sensor, ground sprinkler, CO2-hose-reel. But these state is very insufficient for the fire-safety in cultural property wooden buildings. Specially as particular attention in province, forest fire of regional characteristic have close relation with cultural property fire. The majority of factor against forest and building fire is to provide monitoring and security system; CCTV, Fence, Sensor, Alarm and paid guard man against incendiary. Ultimately it is necessary to construct comprehensive disaster prevention system with the organic cooperation such as National Emergency Management Agency, Cultural Heritage Administration, Forest Service, local government officials and regional citizen.

  • PDF

긴급서어비스 시설의 적정소요 및 배분 (A Study on an Optimal Requirement and Allocation Planning of Emergency Service Facilities)

  • 황학;황흥석;정호원
    • 한국경영과학회지
    • /
    • 제6권1호
    • /
    • pp.75-82
    • /
    • 1981
  • This paper considers urban emergency service systems that dispatch vehicles (facilities) from fixed bases with the objective of finding an optimum allocation of emergency facilities. A case study of fire station problem of Seoul city is conducted to analyze the deployment of fire-fighting resources and develop a class of improved deployment strategies with Parameteric Allocation Model (P.A.M.). The study shows a long term plan leading to balanced fire protection for most fire hazardous districts as well as low alarm districts.