• 제목/요약/키워드: Fire Management

검색결과 1,704건 처리시간 0.025초

감지기의 점검 기술향상을 위한 복합시험기의 개발 (Development of Composite Examination Equipment for Improvement of Fire Detectors Checking Technology)

  • 공하성;이종화
    • 대한안전경영과학회지
    • /
    • 제10권4호
    • /
    • pp.135-143
    • /
    • 2008
  • Recently as the testing of fire detector used the testing device for fire detector, there are something the matter in the perception function loss of fire detector, structure and form of the testing device for fire detector. The problem at oxidation of emitting smoke ashes hazardous article part and so on that checking person absorbs be. In this paper the problem or the conventional the examination equipment of fire detectors is analysed and researched. To solve these problems after the theoretical study and design and paint drawing of equipment the prototype of composite examination equipment of fire detectors was made. After compared with the conventional, part that improve of composite examination equipment of fire detectors are verified through the examination. In the future it will be useful the operation state and correct operation time of the fire detectors are measured after the research about the quality of the material and transparency of bellows cover is done.

Meteorological Determinants of Forest Fire Occurrence in the Fall, South Korea

  • Won, Myoung-Soo;Miah, Danesh;Koo, Kyo-Sang;Lee, Myung-Bo;Shin, Man-Yong
    • 한국산림과학회지
    • /
    • 제99권2호
    • /
    • pp.163-171
    • /
    • 2010
  • Forest fires have potentials to change the structure and function of forest ecosystems and significantly influence on atmosphere and biogeochemical cycles. Forest fire also affects the quality of public benefits such as carbon sequestration, soil fertility, grazing value, biodiversity, or tourism. The prediction of fire occurrence and its spread is critical to the forest managers for allocating resources and developing the forest fire danger rating system. Most of fires were human-caused fires in Korea, but meteorological factors are also big contributors to fire behaviors and its spread. Thus, meteorological factors as well as social factors were considered in the fire danger rating systems. A total of 298 forest fires occurred during the fall season from 2002 to 2006 in South Korea were considered for developing a logistic model of forest fire occurrence. The results of statistical analysis show that only effective humidity and temperature significantly affected the logistic models (p<0.05). The results of ROC curve analysis showed that the probability of randomly selected fires ranges from 0.739 to 0.876, which represent a relatively high accuracy of the developed model. These findings would be necessary for the policy makers in South Korea for the prevention of forest fires.

차동식 열감지기 설치기준 비교분석에 관한 연구 (Differential temperature fire detector analysis of comparative study based on sensor installation)

  • 황동환;양광모;강경식
    • 대한안전경영과학회지
    • /
    • 제16권4호
    • /
    • pp.379-389
    • /
    • 2014
  • Fire detectors are designed to minimize loss of life from a fire alarm system as an alarm to help evacuate more quickly until the completion of the evacuation alarm should be continued. the purpose of such alarms in order to achieve the characteristic fire heat release rate reaches a certain level, or when a certain time has elapsed, when the heat detector is to be alarms to answer. Requires a quick response, it is desirable to install the sensor as much as possible, but taking into account the cost of installation problems by engineering approach to minimize the quantity and rapidity of detection capability should be increased. In order to increase the rapidity of fire detectors in a room according to the height of the sensing period is to be maintained the optimum distance of the fire detector detects characteristics should be considered. Differential spot-type heat detectors installed domestic basis, depending on the type of sensor that can detect one sensor area is limited and less than 4m ceiling height regulations and simply double the number in excess of 4m and intended to be installed.

소방장비의 효과적 운용방안에 관한 연구 (The Study on Effective Maintenance and Management of the Fire Fighting Equipment)

  • 채진;우성천
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.48-60
    • /
    • 2009
  • 최근 소방행정 분야에 인력 및 각종 소방장비의 확충보강 등은 이루어 졌으나 소방장비분야에서는 주로양적 팽창만 이루어진 결과 유지 관리상에 여러 가지 문제점이 나타나고 있다. 소방장비는 특성상 실용성 경제성 내구성이 높고 꼭 필요한 곳에 사용될 수 있는 효과성을 갖고 있어야 하나 현실적인 유지관리 상태는 그렇지 못한 실정이다. 따라서 본 연구는 소방장비 유지 관리에 대한 실태분석에서 도출된 문제점을 비교 분석하여 의사소통의 활성화, 최고 관리자의 관심과 지지, 전문성 확보, 현장에 적합한 장비 보급 등 소방장비의 효과적인 운용방안을 제시함.

아파트 지하주차장 소화기의 유지관리 효율화 방안에 관한 연구 (A Study on the Effective Method of Fire Extinguisher Maintenance In the Underground Parking Lot of the Apartment)

  • 이영삼
    • 대한안전경영과학회지
    • /
    • 제18권3호
    • /
    • pp.1-8
    • /
    • 2016
  • The definition of an apartment is a building more than 5 stories high and which is the standard law. Currently, the number of apartments is increasing much faster than detached houses. Owning an apartment is a normal trend these days. However, the increasing number of apartments has been increasing the number of apartment fires which also has been making social problems. Therefore, this study was conducted for the fire extinguisher among other fire facilities because it is important for initial fire suppression. The research subject is on the fire extinguisher that is in the underground parking lot of 40 apartment complexes which are more than 10 stories. Survey and analysis were conducted for 80 fire extinguishers. There are two fire extinguishers for each apartment. The result of this study is that all installed fire extinguishers are ABC dry chemical type, 92% of them is 3.3kg and that meet the legal height(less than 1.5m). However, the condition such as appearance, inspection, manufactured year, appearance of signs, material of signs, size of signs, etc. was insufficiency. So improvement of law and system that are fire facility construction, maintenance implementation and additional designation of type approval about sign will be needed in my opinion.

국민소득과 화재발생 건수의 상관관계에 관한 연구 (A Study on the Correlation between Fire Statistics and GNI(Gross National Income))

  • 최진만;최재성;최돈묵
    • 대한안전경영과학회지
    • /
    • 제11권4호
    • /
    • pp.147-152
    • /
    • 2009
  • As a results of comparing with fire occurrences and gross national income(GNI), annual fire increasing rate has been 5.6%, and that of GNI has been 11% for the past 55 years. As GNI shows 5.4% higher than fire occurrences, economy growing rate is faster than that of fires. In addition, study has been done every 10 years from 1950's to 2000's. Fire occurrences increase twice as much annually and GNI increases above 3.3 times as much.

숭례문 화재의 감식 사례 연구 (A Case Study of the Sungnyemun Fire for Identification)

  • 최승복;이정진;황태연;이창우;최돈묵
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2009년도 춘계학술대회
    • /
    • pp.1-6
    • /
    • 2009
  • 국보 1호인 숭례문 화재는 화재조사자뿐만 아니라 국민들에게 크나큰 아픔을 안겨 주었다. 이 연구의 목적은 현장조사를 통하여 목조 문화재 화재 시 생성되는 연소패턴과 목재 마루바닥에 인화성물질을 살포 후 착화하였을 때 나타나는 촉진제에 의한 연소 흔적 등을 확인하는데 있다. 또한 이 연구결과는 유사한 화재 발생 시 화재조사요원에게 정확한 화재 원인을 감식할 수 있는 자료가 될 것이다.

  • PDF

화재조사의 협력방안 모색: 민관파트너십이론을 중심으로 (A Cooperating Plan of Fire Investigation: Focused on Public-Private Partnership Theory)

  • 이란희;공하성
    • 대한안전경영과학회지
    • /
    • 제16권1호
    • /
    • pp.37-44
    • /
    • 2014
  • This study is to search cooperation plan about fire investigation based on the public-private partnership. Especially focused on the partnership with 4 sector; the academic world, insurance sector, industrial world, professionalist of private fire investigation. In conclusion, Firstly a partnership with the academic world should have courses or school subject extensions related to fire investigation. Secondly, a partnership with insurance sector should secure trust through unifying estimate standard about the origin of damage. Thirdly, A partnership with industrial company is presented making collaboration team to investigate the fire investigation. Lastly, the partnership with the private professionalist related to fire investigation should strengthen credibility and expertise.

공장소음으로 인한 화재 경보음 인지 영향정도에 관한 연구 (A study on Noise Generation and Awareness of the Fire Alarm Sound in the Factory)

  • 이영삼
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.97-103
    • /
    • 2015
  • The people who are in the noise factory are difficult to hear and recognize about fire and to evacuate quickly when a fire occurs. This study was conducted to analyze workplace's background noise of 31 factories in Incheon and to know the workplace noise level comparing to fire alarm sound level. The measured average noise level was 96.8dB(A). Noise level of measured result was exceeded as 6.8dB(A) comparing to NFSC (National Fire Safety Code) noise level of 90dB. NFPA suggests that when background noise exceeds 85dB or more than that, other methods should be considered to know alarm sound. Also fire alarm sound should exceed more than 15dB(A) comparing to background noise level. Therefore it was concluded that the design of the fire alarm systems should not be applied to the workplace without considering background noise and it needs to be improved with regulations and the systems.

웨어러블 기기의 배터리화재사례와 실험을 통한 화재위험성 분석 (Analysis of Fire Risk through Battery Fire Cases and Experiments of Wearable Devices)

  • 이정일
    • 대한안전경영과학회지
    • /
    • 제22권2호
    • /
    • pp.47-55
    • /
    • 2020
  • This study analyzed ignition probability about Lithium-polymer batteries of what variously were being produced wearable devices recently. The study analyzed ignition probability by PCM(Protection Circuit Module) operating state and overcharged, over-discharged, exposed to high temperatures of Lithium polymer batteries, analyzing wearable devices on the market. Then it classified experimental results to implement analysis comparison about weight, X-ray imaging, battery decomposition. With these experiments, the study analyzed combustion-possibility and fire patterns. These statistics will be used to measure and verify the cause of a fire when identify wearable devices using Lithium-polymer batteries.