• Title/Summary/Keyword: Fire Load Test

Search Result 160, Processing Time 0.032 seconds

Comparative Study on the Estimation Method of Fire Load for Residential Combustibles (주거공간 가연물의 화재하중 산정방법의 비교연구)

  • Choi, Su-Young;Kim, Jung-Yong;Nam, Dong-Gun;Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.38-43
    • /
    • 2013
  • As a preliminary study to evaluate the reliability of the calculation method of fire load for residential furniture combustibles, the present study estimates the fire load considering the volume data obtained by the 3D geometrical information of combustibles and material properties based on the literature survey and sample burning test. A kitchen sink cabinet, couch and workstation were investigated for estimating its fire load and real fire test have been performed to measure total energy released from the combustibles. Based on total energy measured from real fire test, the relative error of the estimated fire load due to literature survey and measured material properties showed 6~120% and less than 20%, respectively. It shows that the estimation error of fire load are greatly affected by its material properties as well as geometrical information of combustibles and the present study will be able to contribute to accurate estimation of fire load.

Characterization of Live Fire Load in Buildings - Heat Release Characteristics of Typical Live Fire Load in Post Office Building - (건축물의 적재가연물 특성에 관한 연구 -우체국 적재가연물의 연소성상 -)

  • Nam, Dong-Gun;Yuji, Hasemi;SaKong, Seong-Ho;Jung, Jong-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.7-10
    • /
    • 2008
  • Heat release characteristics of live fire load are an important parameter for performance oriented fire safety design of a building. While investigations have been carried out on the fire load and its burning behavior in office, residential and commercial buildings and so on, little effort has been paid for the rational treatment of fire load in post office buildings in Japan. In this report, burning behavior of typical combustible objects in post office buildings are studied by measuring heat release rates of plastic palettes with and without postal envelopes or packages and special containers loading numbers of palettes. The test results suggest that dynamic heat release rate is highly dependent on the condition of palettes especially if they load appropriate amount of postal envelopes or not.

  • PDF

An experimental study on fire resistance of medical modular block

  • Kim, Hyung-Jun;Lee, Jae-Sung;Kim, Heung-Youl;Cho, Bong-Ho;Xi, Yunping;Kwon, Ki-Hyuck
    • Steel and Composite Structures
    • /
    • v.15 no.1
    • /
    • pp.103-130
    • /
    • 2013
  • Fire performance and fire safety of high-rise buildings have become major concerns after the disasters of World Trade Center in the U.S. in 2001 and Windsor tower in Spain in 2005. Performance based design (PBD) approaches have been considered as a better method for fire resistance design of structures because it is capable of incorporating test results of most recent fire resistance technologies. However, there is a difficulty to evaluate fireproof performance of large structures, which have multiple structural members such as columns, slabs, and walls. The difficulty is mainly due to the limitation in the testing equipment, such as size of furnace that can be used to carry out fire tests with existing criteria like ISO 834, BS 476, and KS F 2257. In the present research, a large scale calorie meter (10 MW) was used to conduct three full scale fire tests on medical modular blocks. Average fire load of 13.99 $kg/m^2$ was used in the first test. In the second test, the weighting coefficient of 3.5 (the fire load of 50 $kg/m^2$) was used to simulate the worst fire scenario. The flashover of the medical modular block occurred at 62 minutes in the first test and 12 minutes in the second test. The heat resistance capacity of the external wall, the temperatures and deformations of the structural members satisfied the requirements of fire resistance performance of 90 minutes burning period. The total heat loads and the heat values for each test are calculated by theoretical equations. The duration of burning was predicted. The predicted results were compared with the test results, and they agree quite well.

A Study on the Fire Resistance Performance of Reinforced Concrete Columns according to Axial Load Ratio (축력비 조건에 따른 철근콘크리트기둥의 내화성능에 관한 연구)

  • Hwang, Kyu-Jae;Cho, Bum-Yean;Yeo, In-Hwan
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.26-31
    • /
    • 2013
  • This study, to evaluate the technology of the fire resistance design of Reinforced Concrete columns based on fire resistance performance design, was suppose to use as basic data for performance design through a measure of temperature and deformation using heat transfer analysis and Heat-load test of the Reinforced Concrete columns as parameter is the axial load ratio. In accordance with axial load without eccentricity, the load ratio of 0.30, 0.35, 0.40 and 0.47 were imposed on columns. As a result of this study, 0.40 or more of axial load ratio can be ensured that the fire resistance performance was considered satisfactory.

Fire resistance of high strength concrete filled steel tubular columns under combined temperature and loading

  • Tang, Chao-Wei
    • Steel and Composite Structures
    • /
    • v.27 no.2
    • /
    • pp.243-253
    • /
    • 2018
  • In recent years, concrete-filled box or tubular columns have been commonly used in high-rise buildings. However, a number of fire test results show that there are significant differences between high strength concrete (HSC) and normal strength concrete (NSC) after being subjected to high temperatures. Therefore, this paper presents an investigation on the fire resistance of HSC filled steel tubular columns (CFTCs) under combined temperature and loading. Two groups of full-size specimens were fabricated to consider the effect of type of concrete infilling (plain and reinforced) and the load level on the fire resistance of CFTCs. Prior to fire test, a constant compressive load (i.e., load level for fire design) was applied to the column specimens. Thermal load was then applied on the column specimens in form of ISO 834 standard fire curve in a large-scale laboratory furnace until the set experiment termination condition was reached. The results demonstrate that the higher the axial load level, the worse the fire resistance. Moreover, in the bar-reinforced concrete-filled steel tubular columns, the presence of rebars not only decreased the spread of cracks and the sudden loss of strength, but also contributed to the load-carrying capacity of the concrete core.

Calculation of Limit Temperature on H-Beam Flexural Member Through the Thermal Stress Analysis under the Lateral Load (재하된 H형강 휨재의 열응력해석을 이용한 한계온도 산정)

  • Yoon, Sung Kee;Lee, Chy Hyoung;Koo, Bon Hoon
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.4
    • /
    • pp.387-397
    • /
    • 2015
  • The domestic fire resistance performance test is conducted as a prescriptive design method such as quality test. In quality test there are 2 methods, unloaded fire resistance test and fire resistance test under load. In realistic, these tests, however, have problems with expense, time and diversity of structure. This study reviewed fire resistance performance of H-beam flexural member by thermal stress analysis using finite element ABAQUS program. This research is for the performance-based design reviewing applicability of domestic standard. As a result of this study, limit temperatures per each load ratio provied for proper performance of fire resistancy.

Experimental Studies on PSC Airpit-Slab with Fire Resistance Panel under Static and Dynamic Loads (내화패널이 부착된 프리캐스트 PSC 풍도슬래브의 정적/동적하중에 관한 실험연구)

  • Kim, Tae Kyun;Bae, Jeong;Choi, Heon;Min, In Gi
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.4A
    • /
    • pp.245-253
    • /
    • 2012
  • In the longway tunnel and underground traffic road, the structure of transverse ventilation system is constructed by the airpit slab. In this study, the full scale specimens of the PSC airpit slab that attached fire resistance panel are performed the static and dynamic loading tests for evaluation of bending capacity. The first of all, it confirmed the evaluations about the fundamental efficiency of the fire resistance panel and PSC slab by the 3-point bending test and pull-off test. The tests are performed for evaluation of the bending resistance under ultimate static load and the bonded capacity under dynamic fatigue load. A fatigue test is performed for an investigation of the effect on wind pressure that is developed by transit of traffic. The damage or debonding on surface between fire resistance panel and PSC slab was not developed in dynamic fatigue load test, also the behavior of the specimens is very stable and the debonding of the fire resistance panel attached at the bottom surface of PSC slab was not developed in static load test, too. Therefore, the crack or debonding of the fire resistance panel will be not developed by external loads during the construction or completion of the precast fire resistance system.

An Experimental Study on the Thermal Property of Concrete under the Load Ratio Condition in Fire (고온화재조건 콘크리트 라이닝의 하중비에 따른 폭렬영향성 및 화재손상특성에 관한 실험적 연구)

  • Kim, Hyung-Jun;Kim, Heung-Youl;Park, Kyung-Hun;Ahn, Chan-Sol;Kwon, Ki-Hyuk
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.145-151
    • /
    • 2010
  • The fire in tunnel, when failed to extinguish at early stage, tends to easily develop to high temperature and spread to entire area of the tunnel because of considerable level of fire load and smoke control facility within the tunnel, resulting in severe damage to the people and tunnel structure. This study was intended to carry out the fire test with MHC fire curve, a scenario, which has the most rapid fire rise, on assumption of load ratio of 1, 20, 40, 60 and 70%, so as to identify the thermal characteristics of the concrete against spalling and the range of fire damage. The specimen was small scale sample as defined by EFNARC and the mixing ratio was based on 24 MPa, which is considered to be the normal strength. As a result of test, 16mm spalling was occurred on the lining under the non-load condition, while no spalling was occurred with 20% and 40% of load ratio. In case of 60% of load ratio, 24 mm of spalling was occurred and it failed in 10 minutes after heating in case of 70% load condition.

Fire resistance of high strength fiber reinforced concrete filled box columns

  • Tang, Chao-Wei
    • Steel and Composite Structures
    • /
    • v.23 no.5
    • /
    • pp.611-621
    • /
    • 2017
  • This paper presents an investigation on the fire resistance of high strength fiber reinforced concrete filled box columns (CFBCs) under combined temperature and loading. Two groups of full-size specimens were fabricated. The control group was a steel box filled with high-strength concrete (HSC), while the experimental group consisted of a steel box filled with high strength fiber concrete (HFC) and two steel boxes filled with fiber reinforced concrete. Prior to fire test, a constant compressive load (i.e., load level for fire design) was applied to the column specimens. Thermal load was then applied on the column specimens in form of ISO 834 standard fire curve in a large-scale laboratory furnace until the set experiment termination condition was reached. The test results show that filling fiber concrete can improve the fire resistance of CFBC. Moreover, the configuration of longitudinal reinforcements and transverse stirrups can significantly improve the fire resistance of CFBCs.

Temperature and Stress Analysis of Box Culvert in Fire (화재에 의한 지하공동구의 온도 및 응력해석)

  • Kim, Hyun-Jun;Im, Cho-Rong;Yoo, Hyeon-Kyeong;Chung, Chul-Hun
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.6
    • /
    • pp.31-44
    • /
    • 2011
  • This paper has presented a finite element analysis of structural behaviour of box culvert during and after fires. The fire tests were carried out in a furnace on RC slabs using the ISO 834 standard fire curve. The load capacity after cooling of the RC slab that was not loaded during the fire tests was evaluated by means of additional 3 points bending tests. In the past, stress-strain models of concrete under fire loading have been proposed by several researchers. Comparisons are made with the load-displacement relations of RC slabs after fire loading using the existing stress-strain models with temperature, such as Schneider, EUROCODE 2, Lie, Shi and Nan model. By comparing the load-displacement relations, Lie model was found to result in a maximum load about 2.0% higher than that of test. Based on the fire test results of RC slabs, this paper presents an extensive analytical study on the fire response of box culvert during and after fires.