• 제목/요약/키워드: Fire Incident

검색결과 129건 처리시간 0.021초

Mechanical behavior of 316L austenitic stainless steel bolts after fire

  • Zhengyi Kong;Bo Yang;Cuiqiang Shi;Xinjie Huang;George Vasdravellis;Quang-Viet Vu;Seung-Eock Kim
    • Steel and Composite Structures
    • /
    • 제50권3호
    • /
    • pp.281-298
    • /
    • 2024
  • Stainless steel bolts (SSB) are increasingly utilized in bolted steel connections due to their good mechanical performance and excellent corrosion resistance. Fire accidents, which commonly occur in engineering scenarios, pose a significant threat to the safety of steel frames. The post-fire behavior of SSB has a significant influence on the structural integrity of steel frames, and neglecting the effect of temperature can lead to serious accidents in engineering. Therefore, it is important to evaluate the performance of SSB at elevated temperatures and their residual strength after a fire incident. To investigate the mechanical behavior of SSB after fire, 114 bolts with grades A4-70 and A4-80, manufactured from 316L austenitic stainless steel, were subjected to elevated temperatures ranging from 20℃ to 1200℃. Two different cooling methods commonly employed in engineering, namely cooling at ambient temperatures (air cooling) and cooling in water (water cooling), were used to cool the bolts. Tensile tests were performed to examine the influence of elevated temperatures and cooling methods on the mechanical behavior of SSB. The results indicate that the temperature does not significantly affect the Young's modulus and the ultimate strength of SSB. Up to 500℃, the yield strength increases with temperature, but this trend reverses when the temperature exceeds 500℃. In contrast, the ultimate strain shows the opposite trend. The strain hardening exponent is not significantly influenced by the temperature until it reaches 500℃. The cooling methods employed have an insignificant impact on the performance of SSB. When compared to high-strength bolts, 316L austenitic SSB demonstrate superior fire resistance. Design models for the post-fire mechanical behavior of 316L austenitic SSB, encompassing parameters such as the elasticity modulus, yield strength, ultimate strength, ultimate strain, and strain hardening exponent, are proposed, and a more precise stress-strain model is recommended to predict the mechanical behavior of 316L austenitic SSB after a fire incident.

잠재적 화재.폭발 위험 지역 작업용 녹전환형 중방식 코팅제의 특성에 관한 연구 (A Study on the Properties of the Heavy Duty Rust-Converting Agent used in the Potential Hazard Areas of Fire & Explosion)

  • 강영구
    • 한국안전학회지
    • /
    • 제13권3호
    • /
    • pp.102-111
    • /
    • 1998
  • This study was concerned with the development of a heavy duty rust-converting agent, the function of which is to form metal complex coatings, containing vinyl halide-acrylic terpolymer emulsion, defoamer, emulsifying agent, glass flakes, chelating agent such as gallotannic acid, gallic acid, and pyrogallic acid, and other additives. The resulted emulsion products(Sample No.1~No.5) were characterized through test either in the forms of emulsions, which include Viscosity, Penetration rate, Acidity and Film drying rate test, or in the forms of coated layer on rusty steel substrates by FT-IR, which include hardness, gloss, salt spray, adhesion and flame retardant test. The test results are as follows ; Penetration rate(0.1~0.4 mm/min), Solid content(70%), Acidity (pH 1.8~2.0), Specific gravity(1.30~1.35), Film drying rate(108min, RH 40% ; 150min, RH 80%), Gloss(83~92, incident angle $60^{\circ}$; 88~97, incident angle $85^{\circ}$), Pencil hardness(4H~5H), Adhesion (100/100), Salt spray test(>720Hr), LOI(%) value(38%), Vertical burning test(UL 94-v-l). According to the various performance of specimens show above, the evaluation of the availability of this heavy duty rust-converting agent can be concluded that all the samples(No.1~No.5) are capable of being used in the field of chemical plant and in the hazard areas of fire and explosion potential. It was observed that the properties of sample No.2, especially gloss and hardness, were much better than that of the other samples.

  • PDF

건물 내장재의 화재위험성 평가 방법 (A Fire Hazard Assessment of Interior Finish Materials)

  • 김운형
    • 한국화재소방학회논문지
    • /
    • 제12권2호
    • /
    • pp.17-28
    • /
    • 1998
  • 건물 화재시 예상되는 내장재의 실째 화재성농올 기준으로 한 위험성 명가방법올 제시하였다. 이률 위해 ISO Room Corner Test. (9705)를 기준으로 Qui ntie re의 화재확산 모델을 이용하여 내장재의 열 적 특성과 플래쉬 오버 도달시간과의 상관성을 유도하고 스쩨덴의 실제 시험결과와 비교 분석하였다. 이 결과, 내장재의 상대척인 화재위험성은 화재확산 변수 b륨 기준으로 명가될 수 있었다.

  • PDF

난연처리된 목재의 연소속도에 관한 연구 (A Study on the Burning Rate of Fire Retardant Treated Wood)

  • 박형주
    • 한국안전학회지
    • /
    • 제22권6호
    • /
    • pp.46-54
    • /
    • 2007
  • The purpose of this study was to examines the burning rate of fire retardant treated wood in the cone heater with a one-dimensional integral model. The wood samples used in this study were four species. The species of woods are Redwood, White oak, Douglas fir and Maple. Each sample was nominally 50mm thick and 100mm square. Samples were exposed to a range of incident heat fluxes 10 to $35kW/m^2$ using the cone heater. A one-dimension integral model has been used to predict burning rate, heat of gasification, flame heat fluxes, charring rate and char depth of samples. As a result measurement of mass loss rate, softwoods(Redwood and Douglas fir) has relatively low value than those for hardwoods(White oak and Maple). Average charring rate of woods in case of fire retardant treatment showed reduction effect of 41.29%, 50.00%, 48.18% and 60.82% for Redwood, Douglas fir, White fir and Maple, respectively. Almost all the predictions from integral model showed faster charring than those measured. Average difference between predictions and experimental data was 16%, 9.5% and 11.8% for N, F1 and F2 respectively. Water-soluble fire retardant used in this study find out more effect in hardwood than softwood from the result of measurement of mass loss rate and average charring rate.

놀이방 퍼즐매트의 화재위험성에 관한 연구 (A Study on the Fire Hazards of Puzzle Mats in Group Day Care Home)

  • 박형주
    • 한국안전학회지
    • /
    • 제23권5호
    • /
    • pp.73-78
    • /
    • 2008
  • The fire hazards and combustion heat of puzzle mats in group day care home were analysed using variable external irradiation level. The fire hazards such as ignition time, ignition temperature, mass loss rate, and flame temperature profile were measured. Incident heat fluxes of $15kW/m^2$, $20kW/m^2$, $25kW/m^2$, $35kW/m^2$, $50kW/m^2$ and $75kW/m^2$ were selected for these experiments. All samples were tested in the horizontal orientation and were wrapped in a single layer of aluminium foil. Each sample was nominally 20mm thick and 100mm square. Five samples of puzzle mat were tested in the study : Type A, B, C, D and E. Type A, B and C are all general grades whereas Type D and E are both Flame retardant grades. As results, Type E of FR-grade showed the best characteristics in safety of the early fire from ignition time, critical heat flux, and ignition and flame temperature data of this study. All specimen of G-grade(Type A, B and C), however, showed the weak in safety of fire.

산후조리원 화재안전매뉴얼구축을 위한 안전의식 조사 및 개선방안에 관한 연구 (A Study on the Investigation of Safety Consciousness and Improvement Plan for Fire Safety Manual in Postpartum Care Center)

  • 진승현;김혜원;한지우;박성하;이병흔;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.96-97
    • /
    • 2018
  • Facilities used by senior citizens, infants, and disabled people have characteristics that make it difficult to escape on their own or require a lot of evacuation time. Therefore, to ensure safety in case of fire, clear measures for securing safety of facilities, fire response methods, and training are required in accordance with the regulations. In case of postnatal care center facilities, newborn babies and mothers reside 24 hours a day, and as they are located in high-rise and multi-use facilities, measures for fire safety are necessary, but the domestic manual lacks. Accordingly, a field survey for security of the manual revealed that the establishment of awareness and facilities on temporary waiting areas and smoke control, which are easy for evacuation and fire safety, was a problem.

  • PDF

목재 가연물의 두께에 따른 화염연소와 훈소상태에서의 화재특성 (Fire Characteristics of Flaming and Smoldering Combustion of Wood Combustibles Considering Thickness)

  • 김성찬;남동군
    • 한국화재소방학회논문지
    • /
    • 제29권4호
    • /
    • pp.67-72
    • /
    • 2015
  • 본 연구는 콘칼로리미터 실험을 통해 건축물 마감재와 가구소재로 널리 적용되는 목재 가공품의 화염연소와 훈소시 화재특성을 파악하고자 한다. 시험대상 목재 가연물은 MDF, 합판, 칩보드이며 $50kW/m^2$의 복사열유속을 시편에 가하여 점화를 유도하였다. 실험과정에서 화재특성을 나타내는 발열량, 연소가스 생성율, 유효연소율 등의 주요 인자를 가연물의 두께에 따라 정량화하였다. 실험결과 초기 평면방향의 화염전파와 후기 시편의 관통에 의한 화재확대로 인해 단위면적당 발열량에 대한 두 개의 피크점이 관측되었다. 화염연소시의 질량감소율이 훈소시에 비해 5배 이상 높게 나타난 반면에 훈소과정에서 CO 생성율은 화염연소에 비해 10배 이상 높게 측정되어 훈소시 높은 독성가스 생성율을 보였다. 본 연구는 목재 가연물의 화재성상을 이해하고 화재해석을 위한 물성자료로 활용될 수 있다.

소방공무원의 비화재 밀폐공간 구조·구급 활동 중 질식 및 중독재해 사례 분석 (Fire fighters' Asphyxiation Incidents during Confined Space Rescue in Korea)

  • 이주희;강태선
    • 한국산업보건학회지
    • /
    • 제29권4호
    • /
    • pp.590-602
    • /
    • 2019
  • Objectives: This study was conducted to prevent asphyxiation of firefighters during confined space rescue. The specific purpose was to identify the magnitude of the problem, identify the cause of the accidents, and suggest measures to ensure safety of confined space rescues. Methods: We collected data from National Fallen Firefighters Memorial, press releases, and other sources In order to identify the current situation of asphyxiation incidents among firefighters from 1945 to 2019. In addition, an incident investigation was conducted for each case, and the processes, causes, and control measures of the incidents were described as a narrative data entry. Results: Over the past 73 years, eight incidents involving firefighter in Korea have occurred. In these incidents, five firefighters were killed, and eight were injured. The confined spaces incidents occurred were water supply tanks, wastewater treatment tanks, pickling pits, septic tanks, and more. The causes were three cases of hydrogen sulfide poisoning, one of oxygen deficiency, one of carbon monoxide poisoning, and three unclassifiable asphyxiations. The people in need were all workers in various industries. Conclusions: The number of firefighters' deaths and injuries during rescues in confined spaces was severe and the risks have not been completely eliminated. By establishing and implementing a precise incident investigation system, according control measures should be initiatedin order to prevent a recurrence of the same type of disaster and reflected in the SOP. In particular, due to the high risk of occurrence at workplaces, cooperation between fire and rescue authority and relevant agencies such as the Ministry of Employment and Labor and the KOSHA should be strengthened.

붕사, 붕산 및 인산암모늄을 가압 함침한 편백 루버의 연소특성 (Combustion Characteristics of Hinoki Cypress Louver after Pressure Impregnation with Boric Acid, Borax and Ammonium Phosphate)

  • 박형주
    • 한국화재소방학회논문지
    • /
    • 제29권6호
    • /
    • pp.1-5
    • /
    • 2015
  • 본 논문은 편백 루버에 붕산, 붕사 및 인산암모늄 수용액을 가압함침 후 외부 복사열원(25, 30 및 $50kW/m^2$)에 따른 점화시간, 임계 열유속 및 질량감소속도 등의 연소특성을 측정하였다. 실험에 사용된 시료의 크기는 $100{\times}100{\times}10mm$이며, 각 외부 복사열원에서 5분간 변화를 3회 반복 측정하였다. 연구결과, $25kW/m^2$의 외부 복사열원에 있어서 착화시간은 Type C-H를 제외하고는 17.4~21.3%의 지연효과를 나타낸 반면 35 및 $50kW/m^2$에서는 큰 차이가 없음을 알 수 있었으며, 평균질량감소속도는 Type A-H와 Type D-H에서 Type N-H보다 낮게 측정되었다. 또한, 외부 복사열원에 따른 착화시간으로부터 임계 열유속은 $14.79{\sim}17.17kW/m^2$$10.7kW/m^2$인 Type N-H보다 38.22~60.46% 높게 예측됨에 따라 초기 화재시 화재확대에 대한 지연효과가 있을 것으로 예상된다.