• Title/Summary/Keyword: Fire Extinguisher

Search Result 93, Processing Time 0.027 seconds

The Suitability Evaluation of Training on How to Use Fire Extinguisher through Analyzing Fire Safety Awareness of Preschoolers - Based on Preschoolers in Nowon-gu and Seongbuk-gu - (영유아의 화재안전 의식수준 분석을 통한 소화기 사용 교육의 적합성 평가 - 노원구와 성북구 소재 영유아를 대상으로 -)

  • Lee, Se-Myeoung
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.3
    • /
    • pp.155-163
    • /
    • 2014
  • Preschoolers are the most effective age to start fire safety education. But, if the education contents are inappropriate, they may form the wrong habit to preschoolers. Many educational contents of fire safety in Korea are not so obvious in the principle and order of priority about what to do during fire and they often contain unnecessary contents to preschoolers such as how to use fire extinguisher. This paper has analyzed fire safety awareness of preschoolers and teachers and, based on the results, has claimed unsuitability of training on how to use fire extinguisher and has suggested the improvement of fire safety education.

Analysis of the Apparent Specific Gravity for Type-3 Dry Chemical Powder with the Changes in the Internal Pressure of Dry Chemical Extinguisher (분말소화기의 내부압력 변화에 따른 제3종 분말소화약제의 겉보기비중 실험 분석)

  • Ju-Dal, Son;Seo-young, Kim;Ha-sung, Kong
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.3
    • /
    • pp.607-617
    • /
    • 2023
  • This study aims to analyze whether the performance of the fire extinguisher meets the criteria for the apparent specific gravity property test by calculating the change in internal pressure and the use period of the fire extinguisher as a new one with 5 years, recycled one with 5 years, a new one with 10 years, and a new one with 13 years, respectively. As a result of the experiment, when the internal pressure of the fire extinguisher was 0%, the first, second, and third arithmetic mean analysis of the dry chemical extinguisher according to the use period was found to be condemned. When the internal pressure of the fire extinguisher was 50%, it was measured as 130 ml in sample 12-08-new and analyzed as unsuitable. Also, sample 09-09-new of a new dry chemical extinguisher with 13 elapsed years measured 145ml, which was found inappropriate. All other dry chemical extinguishers were analyzed to be suitable. All were noted suitable when having normal internal pressure of the fire extinguisher, except for sample 09-06 of a new dry chemical extinguisher with 13 elapsed years, which was determined to be unsuitable caused by measuring as 131 ml for experimental value. As a result of experiments, some of the apparent specific gravity tests of dry chemical extinguishers from 10 years to 13 years have found that they are unsuitable for the performance of the fire extinguishers due to the massive phenomenon. Accordingly, it is necessary to reduce the endurance period of dry chemical extinguishers from 10 years to 7 years.

A Study on the Status of Recharging of Fire Extinguishers (수동식소화기의 재충전 현황 및 문제점 연구)

  • Park, Yong-Hwan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.47-55
    • /
    • 2005
  • Fire extinguisher, which is cost effective and easily accessible, is a very effective way of fire suppression. To keep its initial performance it needs periodical inspection and appropriate maintenance. However, many fire extinguishers of which the powder is incompletely coated deteriorates due to the moisture and leak of charge pressure after several years. Accordingly inappropriate powder replacement and pressurization has widely been doing by unqualified persons. Also, the absence of lifetime for fire extinguisher made people keep old bad fire extinguisher without precise inspection. This study specified those issues through case studies and suggested some ways for the systematic improvement.

  • PDF

Fire Extinguisher Maintenance System using Smart NFC Communication and Real-Time Pressure Measurement (스마트 NFC 통신과 실시간 압력 측정을 이용한 소화기 유지관리 시스템)

  • Park, Byeng-Cheol;Park, Ki-Hong
    • Journal of Digital Contents Society
    • /
    • v.18 no.2
    • /
    • pp.403-410
    • /
    • 2017
  • In this paper, the fire extinguisher maintenance system using smart NFC communication and the real-time pressure measurement is proposed. The proposed system consists of three steps in the flow of information. The first step is to identify the fire extinguisher through NFC tagging in the fire extinguisher module using the smart device. The fire extinguisher appearance check and the real-time pressure measurement is performed in the second step, and the last step sends the check status information to the management server. In particular, the actual pressure value is calculated based on the angle of the green area and the indicating needle. Some experiments are conducted so as to verify the proposed system, and as a result, the proposed system shows that the administrator can effectively control the status information of fire safety check.

A Measure on the Use of Metal Fire Extinguisher for Effective Early Extinguishment of Magnesium Fire (마그네슘 화재의 효과적인 초기소화를 위한 금속화재용 소화기 활용방안에 관한 연구)

  • Nam, Ki-Hun;Lee, Jun-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_2
    • /
    • pp.795-800
    • /
    • 2021
  • Magnesium fires require early fire extinguishment due to impulsive and rapid-fire expansion that makes difficult fire fighting. For this reason, efficient early fire fighting and appropriate prevention of fire spread are considered mainly as significant fire extinction measures. However, there is a limit to developing tools for metal fire fighting, such as devices, facilities, and fire extinguishing agents, due to a lack of regulatory instruments in South Korea. It often generates challenges to early fire fighting implementation by fire responders. Thus, the aim of this study is to investigate a measure for securing the efficiency of early fire fighting in magnesium. This study identified the applicability of the metal fire extinguisher used in the United States for magnesium fire through a performance test of a fire extinguishing agent for metal fire. Moreover, we implemented a free burning experiment using magnesium powder to compare varying combustion and extinction process that could occur during applying metal fire extinguishers. Finally, this study suggests measures of the use and application of metal fire extinguishers for magnesium.

An Analysis on Storing Container Corrosion of Powder Extinguisher according to Durable Years of Each Type-3 Powder Extinguisher (제3종 분말소화기 대상별 내용연수에 따른 저장용기의 부식도 분석)

  • Son, Ju-Dal;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.6
    • /
    • pp.661-666
    • /
    • 2022
  • This study presented the criteria for analyzing the corrosion of the powder extinguisher storage container according to the useful life, and conducted an experiment on the market area, the factory area, and the apartment building area to ensure proper performance at all times and drew the following conclusions.First, the experimental value for the degree of corrosion of external contact storage containers was found to be unsuitable in the factory area in 2014. In 2012, the experimental value for the degree of corrosion of external contact storage containers in apartment complexes was found to be inappropriate. Second, the experimental value for the dropout of the external paint in the storage container was found to be inappropriate in the factory area in 2014. In 2012, the experimental value of the degree of coating of the external paint storage container in the apartment building area was found to be inappropriate. It was analyzed that the useful life of the fire extinguisher is 10 years, and if it passes the sample test only once, it will be used for up to 13 years, but in fact, the difference varies greatly depending on the surrounding environment of the fire extinguisher place. Since the degree of corrosion of the storage container of the fire extinguisher from 8 years of the fire extinguisher's useful life is clearly decreased, it is judged that 5 years of the fire extinguisher is appropriate.

Fire Suppression Performance of a New Automatic Fire Extinguisher with Fusible Metal Detectors (이융성금속 응용 자동감지형소화기의 소화성능 특성에 관한 연구)

  • 박용환
    • Fire Science and Engineering
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • In general, small buildings and residence housings rely on manual fire extinguishers instead of automatic fire suppression systems, which causes bigger disasters during the absence of human-beings or in the presence of children or the olders. For this reason, simple structured and low-cost automatic fire extinguisher using fusible metal detector was newly developed and patented. In this paper, some field tests were carried out to investigate its fire suppression performance. As a result, reaction time of the detection parts varied from 2 min 19s to 7 min 20s depending upon the room size and installation position. It was suggested that to reduce reaction time within 3 minutes, fusible metals with lower melting point should be adopted and the installation location should be moved to near ceiling instead of below 1.5 m.

A Study on Clean Agents for Halon Replacement in the Portable Extinguisher with CO2 as an Expellant Gas (이산화탄소를 가압원으로 하는 할론대체 소화기용 청정소화약제에 대한 연구)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.51-55
    • /
    • 2019
  • To prevent ozone depletion caused by CFCs, the replacement of Halon with clean agents has been developed in the fire protection field along with refrigerants, detergents, and foaming agents. The alternatives for Halon 1211 have been developed in the portable fire extinguisher area and HCFC-123 is used widely as a clean fire extinguishing agent. The type of expellant gas is important because their own vapor pressure is low. In this study, HCFC-123, HCFC-124, HFC-125, and Novec-1230 were selected as fire extinguishing agents and CO2, which is expected to improve the fire extinguishing ability, was chosen as the expellant gas. For each agent, experiments changing the agent and CO2 amount were carried out and HCFC-123 showed a good result, as expected. The extinguisher, HCFC-123 of 1.5 kg, showed the same ability to suppress a class A and B fire as the extinguisher, HCFC-123 of 2.5 kg, which is currently sold on the market. According to this result, the expellant gas has a subsidiary fire extinguish effect. This can reduce the amount of HCFC fire extinguishing agent, which is categorized in the phase-out alternatives, and is a more eco-friendly and economical fire extinguisher than the previous one. This study can also help solve the problems of CO2 fire extinguishers for class B and C fires, and can be used to extinguish electric and electron facilities fire, which contains large amounts of class A fire combustibles.