• 제목/요약/키워드: Fire Department

검색결과 3,204건 처리시간 0.025초

FDS를 이용한 실내화재 모사의 문제점 II. 벽면형 및 모서리형 화재 (A Numerical Study of a Room Fire for Fire Sizes II. wall fire and corner fire)

  • 고경찬;박외철
    • 한국안전학회지
    • /
    • 제19권3호
    • /
    • pp.9-13
    • /
    • 2004
  • To confirm the previous finding that FDS predicts a fire growth rate too rapid compared with an experiment in a center fire in a room with an opening, the same computational fluid dynamics was applied to two types of fires, wall fire and comer fire. First the grid size was chosen to eliminate possible numerical errors due to a coarse grid system. Then the two types of fires were simulated for three different fire sizes, 7.65, 21.25, and 51.57kW for each type, which are the same as in the experiment to be compared with. The fires were predicted to grow too fist although the average temperatures and heights of the neutral planes were in good agreement with measurement.

Transient heat transfer analysis using Galerkin finite element method for reinforced concrete slab exposed to high elevated temperature

  • Han, Byung-Chan;Kwon, Young-Jin;Lee, Byung-Jae;Kwon, Seung-Jun;Chae, Young-Suk
    • Computers and Concrete
    • /
    • 제18권6호
    • /
    • pp.1097-1112
    • /
    • 2016
  • Fire loading causes a critical collapse of RC (Reinforced Concrete) Structures since the embedded steels inside are relative week against high elevated temperature. Several numerical frameworks for fire resistance have been proposed, however they have limitations such as unstable convergence and long calculation period. In the work, 2-D nonlinear FE technique is proposed using Galerkin method for RC structures under fire loading. Closed-form element stiffness with a triangular element is adopted and verified with fire test on three RC slabs with different fire loading conditions. Several simulations are also performed considering fire loading conditions, water contents, and cover depth. The proposed numerical technique can handle time-dependent fire loading, convection, radiation, and material properties. The proposed technique can be improved through early-aged concrete behavior like moisture transport which varies with external temperature.

단일화재실험을 통한 FDS 신뢰성 분석 연구 (A Reliability Analysis on FDS through Full Scaled Fire Experiment of a Sing Fire Area)

  • 김동은;김봉찬;서동구;이주희;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2012년도 춘계학술발표회 초록집
    • /
    • pp.282-285
    • /
    • 2012
  • 최근 화재시뮬레이션을 이용한 화재위험성평가를 많이 실시하고 있다. 이에 따라 화재시뮬레이션에 대한 중요성도 강조되고 있으나, 국내에서는 화재시뮬레이션에 대한 신뢰성에 대한 연구는 미흡한 실정이다. 따라서 본 연구에서는 단일구획의 화재실험을 실시하고 각 가연물의 연소 특성 실험을 적용한 FDS와 일반적으로 구동하는 FDS의 비교를 실시하여 FDS의 신뢰성을 알아보았다.

  • PDF

가연물 연소 특성 분석에 관한 연구 (A Study on Fire Behavior analysis of Combustibles Experiment of a Sing Fire Area)

  • 김동은;김봉찬;서동구;이주희;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2012년도 춘계학술발표회 초록집
    • /
    • pp.416-419
    • /
    • 2012
  • 본 연구는 주거시설 중 공동주택의 가연물 조사결과를 토대로 9개의 시료를 ISO-9705의 Furniture Calorimeter의 실험결과를 토대로 연소 실험한 결과의 HRR값을 기존의 범용화재시뮬레이션 FDS에 적용 가능한 HRR유형화 곡선화시키고 이에 따른 가연물 연소특성에 대한 분석방법에 대해서 제시하여 기존 국외 문헌 및 실험 결과를 토대로 실시하고 있는 화재 시뮬레이션의 사용에 있어서의 신뢰성 향상을 목적으로 하고 있다.

  • PDF

2005년 낙산사 화재 후 소방대책의 환경변화에 관한 조사 연구(II) - 낙산사 주변지역의 영향 및 방재의식 변화에 관한 조사 - (A Study on the Environment Change of Fire Protection System After Naksan Temple Fire in 2005 year(II) - A Study on the Influence of Naksan Temple Area and the Change of Disaster Prevention Attitude -)

  • 구원회;정해준;신호준;백민호
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 추계학술논문발표회 논문집
    • /
    • pp.442-445
    • /
    • 2011
  • 2005년 4월 강원도 산불로 인해 낙산사 화재가 발생하여 많은 문화재의 손실이 발생하여 문화재에 대한 소중함과 경각심을 일깨워 주었으며 화재로 인해 발생하는 문화재 손실을 막기 위해 많은 노력이 요구되었다. 본 연구는 강원도 중요 목조문화재인 낙산사 화재 발생 후 6년이 지난 현 지점에서, 주민 방재의식조사를 통해 낙산사 주변지역의 방재의식 변화에 대해 알아보고 이를 바탕으로 문화재 방재대책을 제안하고자 한다.

  • PDF

An experimental study on fire resistance of medical modular block

  • Kim, Hyung-Jun;Lee, Jae-Sung;Kim, Heung-Youl;Cho, Bong-Ho;Xi, Yunping;Kwon, Ki-Hyuck
    • Steel and Composite Structures
    • /
    • 제15권1호
    • /
    • pp.103-130
    • /
    • 2013
  • Fire performance and fire safety of high-rise buildings have become major concerns after the disasters of World Trade Center in the U.S. in 2001 and Windsor tower in Spain in 2005. Performance based design (PBD) approaches have been considered as a better method for fire resistance design of structures because it is capable of incorporating test results of most recent fire resistance technologies. However, there is a difficulty to evaluate fireproof performance of large structures, which have multiple structural members such as columns, slabs, and walls. The difficulty is mainly due to the limitation in the testing equipment, such as size of furnace that can be used to carry out fire tests with existing criteria like ISO 834, BS 476, and KS F 2257. In the present research, a large scale calorie meter (10 MW) was used to conduct three full scale fire tests on medical modular blocks. Average fire load of 13.99 $kg/m^2$ was used in the first test. In the second test, the weighting coefficient of 3.5 (the fire load of 50 $kg/m^2$) was used to simulate the worst fire scenario. The flashover of the medical modular block occurred at 62 minutes in the first test and 12 minutes in the second test. The heat resistance capacity of the external wall, the temperatures and deformations of the structural members satisfied the requirements of fire resistance performance of 90 minutes burning period. The total heat loads and the heat values for each test are calculated by theoretical equations. The duration of burning was predicted. The predicted results were compared with the test results, and they agree quite well.

일본 동경소방청의 피난안정성평가 시뮬레이션 기술개발 사례연구 (A Investigation Study on the Development of Egress Simulation for Evacuation Safety Evaluation of Tokyo Fire Dept. Department in Japan)

  • 이현진;서동구;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.216-222
    • /
    • 2008
  • A large number of Computer-based fire growth and Evacuation model have been developed for various purpose and many of these are widely used for research and engineering. And Most of Egress simulation program are ordinary case only related to human behavior But Egress safety Evaluation is very closed to smog movement. It is well known that the Egress simulation program made by Tokyo Fire Department are related to smog movement. So It is the aim of this study to investigate on the Development of Egress Simulation for Evacuation Safety Evaluation of Tokyo Fire Dept. Department in Japan.

  • PDF

Fire Behavior of Steel Columns Encased by Damaged Spray-applied Fire Resistive Material

  • Kwak, Yoon Keun;Pessiki, Stephen;Kwon, Kihyon
    • Architectural research
    • /
    • 제10권1호
    • /
    • pp.1-11
    • /
    • 2008
  • A Steel column with damaged spray-applied fire resistive material (SFRM) may exhibit reduced structural performance due to the effects of elevated temperature during fire events. Thus, the fire load behavior of steel columns with removed or reduced SFRM needs to be examined to predict the structural damage by fire. FEM analyses were performed for the flange thinning removal models in which the SFRM was reduced as a constant strip in thickness at the top flange of the column. The temperature results for all models obtained from the heat transfer analyses were included as an initial condition in the FEM structural analyses. In this study, the results of analysis show that even small remnants of SFRM led to an effective reduction of temperature at any given fire duration, and improved significantly the axial load capacity of a column as compared to the complete removal cases of SFRM.

화재저감정책의 현황과 개선과제 (Current Status of Fire Reduction Policy and Its Policy Impressions)

  • 조광희;김성일;강경식
    • 대한안전경영과학회지
    • /
    • 제19권3호
    • /
    • pp.19-25
    • /
    • 2017
  • To minimize and prevent the increasing fire and personal injury, the domestic firefighting organizations are making continuous efforts to strengthen the response system and safety standards. "Fire Reduction Program" has been prepared to reduce the outbreak of fire up to 20% in the next 10 years, and the analysis of fire sources should be done and its countermeasures also should be done accordingly. Therefore, the management status, the improvement tasks, and the limitations of the implementation plan are reviewed and studied so that the implementation and goal of the "Fire Reduction Policy" can be achieved.

INFLUENCE OF AERIAL FIRE FIGHTING ON INTENSITY OF RADIATION FROM FIRE

  • Iwata, Yusaku;Koseki, Hiroshi;Kon, Fumio
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.269-274
    • /
    • 1997
  • A large scale fire experiment was conducted through the collaboration between the Tokyo Fire Department and the National Research Institute of Fire and Disaster (NRIFD) for the purpose of studying the effectiveness of aerial fro fighting against urban fire. Ten model houses and ten collapsed model houses were arranged in an area of about $2,000\;m^2$. Water was dropped totally fourteen times by helicopters onto the model houses. In order to know influence of water drop, radiation was measured by four radiometers and four IR (Infrared) cameras, which were set around the burning area. In this report, the influence of aerial Ore fighting on fire was discussed in terms of irradiance and IR images. Data of irradiance, flame temperature and flame area showed that influence of each water drop continued only at most a minute.

  • PDF