• Title/Summary/Keyword: Fire Alarm System

Search Result 163, Processing Time 0.029 seconds

Notify boiling water by using TMP36 sensor

  • Lau, Shuai
    • Korean Journal of Artificial Intelligence
    • /
    • v.4 no.1
    • /
    • pp.8-10
    • /
    • 2016
  • These days, citizens have a lot of ways to get access to IT. In the past, they tended to neglect IT that was thought to be difficult. But, currently, everyone can manufacture and get access not only software but also hardware when he has an idea. Arduino is used. Rinnai had recently released new product named Smart Sensor Range. Safe consumer who gave priority to the safety made new trend gave attention to fire prevention and smart sensor range. The ones who buy gas range prefer safety to economic advantage and/or fire power. The safety system does not always prevent fire accident. This study makes design and produces alarm that perceives temperature of pot when boiling. Not only temperature sensor but also alarm sensor was used to make alarm of boiling water and to give convenient living life. The arduino can be used at practical life to make products for various kinds of people. The invention can give convenience to housewives at kitchen, children and many persons making use of gas range. Another function can be added to develop. This arduino can develop a lot of products by using the study and other designs.

Intelligent Diagnostic System of Photovoltaic Connection Module for Fire Prevention (화재 예방을 위한 태양광 접속반의 지능형 진단 시스템)

  • Ahn, Jae Hyun;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.3
    • /
    • pp.161-166
    • /
    • 2021
  • To prevent accidents caused by changes in the surrounding environment or other factors, various protection facilities are installed at the photovoltaic connection module. The main causes of fire are sparks due to foreign substances inside the photovoltaic connection module through high temperature rise and dew condensation in the photovoltaic connection module, and fire due to heat from the power diode. The proposed method can predict the fire by measuring flame, carbon dioxide, carbon monoxide, temperature, humidity, input voltage, and current on the photovoltaic connection module, and when the fire conditions are reached, fire alarm and power off can be sent to managers and users in real time to prevent fire in advance.

Study on Theoretical Research to Reduce Fire Risk of Solar Power System (태양광 발전 시스템의 화재 위험 감소 방안에 관한 이론적 연구)

  • Park, Kyong-Jin;Lee, Guen-Cull;Lee, Bong-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.2_2
    • /
    • pp.219-224
    • /
    • 2020
  • This study is based on the principle of solar power system and fire breakout. The result of the survey indicates that a solar power system is vulnerable to fire due to lack of maintenance after the installation. Currently the national fire safety agency does not have standards and legal provisions for the installation and maintenance of solar power facilities. Therefore, it increases the risk of fire breakouts as well as possibility of electric shock for the firefighters during fire fighting. This results possible damages to the human and equipments. In this study is proposing an automatic fire extinguishing system to reduce the power generation of solar panels during fire breakouts. Also, propose an over load current alarm system and fire prevention measures for fire fighters. The results of this study will be used as basic data for further fire testing of solar power systems.

A Study on the Awareness of Fire Safety and Evacuation Guide System (화재안전의식 및 피난유도 시스템에 대한 연구)

  • Baek, Eun-Sun;Baek, Geon-Jong;Shin, Hoon;Song, Min-Jeong;Kook, Chan;Kim, Sun-Woo
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.45-53
    • /
    • 2010
  • The purpose of this study is to find out the most effective evacuation alarm sound which is the one of the most important element of the evacuation guidance system as a fundamental mechanism to minimize the damages of a fire. In this regard, a survey was conducted against the firefighting officers and the general public with questions about the general awareness of fire and their preference to various kinds of fire alarm sounds. The result showed that 1) even though the awareness of the interviewees on fire was improving while there were in familiar places like homes or works. But, when they were situated in unfamiliar locations, the fire safety awareness could not be deemed to be strong. This in turn calls for the education of the public and improvement of the existing policies for the enhancement of the fire related safety awareness in unfamiliar environments. 2) For the question about the possible time they could survive in a fire or the time required for safe evacuation, it turned out that the interviewees were thinking of the time required for evacuation to be short, which calls for proper actions. 3) When the visibility in a fire situation is highly limited, the most preferred answer for the alarm sound was a female voice, saying "The emergency exit is this way," accompanies with flashing lights of sirens for the emergency evacuation guidance.

Experimental Performance Evaluation of a Fire System for Apartment Buildings (공동주택 전용화재시스템의 성능평가를 위한 실험적 연구)

  • Jung, Jong-Jin;Hong, A-Reum;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.51-56
    • /
    • 2015
  • In Korea, measures to maintain sustainable fire safety performance for apartment buildings are insufficient in terms of fire-fighting products, skilled personnel, and maintenance status. Also, because of the particular features of a fire compartment, it has structural problems that are very likely to cause damage to human life when a fire occurs. Currently, problems with the fire supervisory system installed in an apartment building cannot be checked in real time, so it is difficult to identify the location of a fire accurately. Protected areas are also not assigned to each household, and residents cannot be clearly informed of the occurrence of a fire. As a consequence, safety evacuation cannot be secured. In addition, it is impossible to test the operation performance for water detectors in sprinkler fire extinguishing systems outside of the household. Therefore, an experiment was conducted to evaluate the performance of a remote fire supervisory system. The results show that the system satisfies all performance requirements. Also, an household alarm system was installed in each household to alert of any occurrence of a fire accurately, and the performance of the alarm system was improved to ensure that residents were quickly evacuated.

Development of CAN based Automatic Fire Detection System

  • Lee, Hong-Hee;Kim, Jung-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.695-699
    • /
    • 2003
  • It is general to use the control network in control systems in order to reduce the complexity of the related wiring harnesses and to improve the system flexibility. CAN becomes one of the most popular network protocols because of its low price, multiple sources, high performance and reliability. This paper describes a CAN based real-time control of the fire detection system for the intelligent building system. The proposed fire detection and alarm system is stronger than the previous one against noises and communication media faults and can solve many problems such as complex cabling and increment of I/O ports by using many sensors. Furthermore, MMI can be achieved easily with the personal computer that is used for replacing the traditional monitoring system. The proposed system is implemented and the experimental results are given.

  • PDF

Analysis of the Causes of Multiple Casualties in an Electronics Factory Fire (전자공장 화재의 다수 사상자 발생원인 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.130-139
    • /
    • 2019
  • The electronics factory fire, that occurred at 15:40 on August 21, 2018, killed nine people and injured six. This study analyzes the causes of many of the casualties from the fire, and is based on fire investigation results and so on. The findings suggest that major causes included failure of the automatic alarm system to function, failure of the emergency broadcasting system to function, the fire suddenly spreading due to polyurethane foam in a ceiling on the 4thfloor, a power outage immediately after the fire started, a sprinkler system that was not working, a delay in reporting the fire, and improper management of fire facilities by a fire safety management company.

Introduction of Intelligent fire-disaster Surveillance System for Subway Station (도시철도 역사 지능형 화재감시시스템 구축방안 연구)

  • Shin, Jeong-Ryol;An, Tae-Ki;Jeon, Bo-Ik;Kim, Gab-Young;Kim, Hyung-Min;Yun, Byeong-Ju
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.457-465
    • /
    • 2009
  • Subway system including light-rail transit system is the representative public urban transportation. Accordingly, Nothing is more important than the safety operation as well as passengers' convenience. Due to the fire disaster of Daegu subway on 2003, more strict regulations of detecting fire and of conducting on emergency circumstances. However, regardless of this improved management, it was reported that installations of lots of fire-detection facilities may be harm than good to operate subway system due to frequent malfunction of some fire-detection facilities. It may cause mis-alarm for fire and induces abnormal operation of subway due to the strict regulation; the train shall be stopped on emergency circumstances. Therefore, in this paper, new scheme on surveiling breaking-out-of fire in the station is suggested with new IT technologies, Wireless Sensor Network(WSN) and CCTVs. which were integrated with an intelligent software. This intelligent system enables to surveil breaking-out-of fire in real time through sensor network technology and watch the emergency site on CCTV as well. Through this system, subway organizers could cope with the emergency circumstance rapidly as well as judge precisely whether fire breaks out or not.

  • PDF