• Title/Summary/Keyword: Fire Accident

Search Result 703, Processing Time 0.023 seconds

Research on Characteristics of Arcing Circuit and Evaluation of Societal Cost caused by AFCI Installation (아크 회로의 특성 분석 및 AFCI 설치로 인한 사회적 비용평가에 관한 연구)

  • Park, Chee-Hyun;Bae, Suk-Myeong;Lim, Yong-Bae;Kim, Gi-Hyun;Choi, Myung-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.144-150
    • /
    • 2007
  • As usage of electric power is increased, the electric fire accident occurrences are growing, too. According to statistics it can be known that electric fire occupies the most weight. However, the method that can detect electric fire accurately is not being developed yet. This paper analyzes the cause of electric fire and the characteristics of Arc Fault Circuit Interrupter(AFCI). First this paper compares AFCI with existing molded-case circuit breaker and finds the hazards caused by arc through power calculation and compares with danger by short circuit. And we suggest the necessity of AFCI through studying relationship of AFCI installation and societal cost.

Cause Investigation and Verification of Fire Accidents for Road and Street Lighting (가로등 화재사고의 원인규명과 검증)

  • Shong, Kil-Mok;Han, Woon-Ki;Kim, Jong-Min;Kim, Young-Seok;Kim, Myoung-Soo;Kim, Hyeok-Soo
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.31-36
    • /
    • 2008
  • This paper carried out a variety of analysis for a finding out the causes of fire on the street lamp. The glass bulb of 250W metal-halide(MH) lamps attached with the impurities rose the temperature by at $410.4^{\circ}$ in normal condition. Therefore, a lamp apparatus is needed the improvement for ventilation and the protection against dust. The heat of MH lamps is diffused through out the luminous tube, a glass bulb, and apparatus by degrees. The accident cause of the lamp is presumed that the accumulated heat by deposits of the inner part. It will be recommended the improvement of the structure that aren't the external impurity and accumulated heat in the MH lamps set.

  • PDF

Construction of Event Tree & Fault Tree for Train Fire Risk Assessment (철도화재사고 위험도평가를 위한 Event Tree 및 Fault Tree 구성)

  • Kwak, Sang-Log;Wang, Jong-Bae;Lee, Bong-Seob;Park, Chan-Woo
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.6
    • /
    • pp.530-535
    • /
    • 2008
  • After train fire accident in Daegue, many research on train fire safety improvement have been carrying out. Since many alternative fire safety measures can be applied in our railway system, the effect of the each safety measure must be quantified prior to the safety investment. In order to estimate the effects of each safety measure quantitatively, fault trees and event trees are constructed in this study. Results can be applied for cost-benefit analysis or sensitivity analysis for safety measures in risk assessment process.

A Study on the Application of Simple Sprinkler Facility at Single Housing (단독주택의 간이스프링클러설비 적용에 관한 연구)

  • Hong, Sung-Woo;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.33-41
    • /
    • 2008
  • Presently, there is no legal regulation pertaining to the installation, maintenance, management and operation of fire-fighting facilities in single housing in Korea, relying instead on the awareness of the residents which hopefully will prevent fire. Likewise, accident prevention effort is very limiting and weak. Accordingly, this research examines current situation in which fire results, identifies root causes and studies application of regulations and develop design measures centered on the single housing that is most afflicted with fire. As part of the measure to prevent fire that afflict housing, it is necessary to classify single housing as specific target for fire fighting just like the joint housing among the types of the building structures that are classified according to the usage on the "Appendix Chart I of the Enforcement Ordinance of the Construction Law" for management purpose. Moreover, it is necessary to make the installation of fire-fighting facilities such as simple sprinkler facility for residential area, fire extinguisher, warning system and others for the sake of the senior citizens and disabled people who reside in single housing, mandatory.

Thermal Image Real-time estimation and Fire Alarm by using a CCD Camera (CCD 카메라를 이용한 열화상 실시간 추정과 화재경보)

  • Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.92-98
    • /
    • 2016
  • This study evaluated thermal image real-time estimation and fire alarm using by a CCD camera, which has been a seamless feature-point analysis method, according to the angle and position and image fusion by a vector coordinate point set-up of equal shape. The system has higher accuracy, fixing data value of temperature sensing and fire image of 0~255, and sensor output-value of 0~5,000. The operation time of a flame specimen within 500 m, 1000 m, and 1500 m from the test report specimen took 7 s, 26 s, and 62 s, respectively, and image creation was proven. A diagnosis of fire accident was designated to 3 steps: Caution/Alarm/Fire. Therefore, a series of process and the transmission of SNS were identified. A light bulb and fluorescent bulb were also tested for a false alarm test, but no false alarm occurred. The possibility that an unwanted alarm will be reduced was verified through a forecast of the fire progress or real-time estimation of a thermal image by the change in the image of a time-based flame and an analysis of the diffusion velocity.

A Study on Fire and Evacuation of TrainingShip HANBADA using FDS (FDS를 이용한 실습선 한바다호 화재 및 피난 연구)

  • KIM, Won-Ouk
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.29 no.2
    • /
    • pp.380-385
    • /
    • 2017
  • Maritime accidents caused by a ship include collisions, sinking, stranding and fire etc. This study is intending to consider fire accidents among such diverse marine accidents. It is much likely that various sorts of fires break out because crews are living in a narrow space for long periods of time consequent on the ship's characteristic of sailing on the sea. This study carried out a simulation through the special program for fire analysis - FDS (Fire Dynamics Simulator) in order to find the effective evacuation time, i.e. life survival time. Particularly, this study did comparative analysis of the influence on the survival of cadets based on the collected simulation data by fire size and sort. As a result of the analysis, It was analyzed the Evacuation Allowable Limit Temperature $60^{\circ}C$ and resulted that there is no influence in evacuation by temperature. In case of visibility analysis, it reached to 5m which is the Evacuation Allowable Limit at 117 seconds under the condition of wood fire in 1MW. When there is Kerosene in 1MW, it took 92.4 seconds to reach by 5m which is the Evacuation Allowable Limit. Theoretical evacuation time for the non-tilted ship was 118.8 seconds in 1MW sized fire so it is shown that the most passengers are met the evacuation safety in case of wood fire. However, the majority of passengers could not be ensured the evacuation safety in Kerosene case.

Evaluation on Sensitivity and Approximate Modeling of Fire-Resistance Performance for A60 Class Deck Penetration Piece Using Heat-Transfer Analysis and Fire Test

  • Park, Woo Chang;Song, Chang Yong
    • Journal of Ocean Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.141-149
    • /
    • 2021
  • The A60 class deck penetration piece is a fire-resistance apparatus installed on the deck compartment to protect lives and to prevent flame diffusion in the case of a fire accident in a ship or offshore plant. In this study, the sensitivity of the fire-resistance performance and approximation characteristics for the A60 class penetration piece was evaluated by conducting a transient heat-transfer analysis and fire test. The transient heat-transfer analysis was conducted to evaluate the fire-resistance design of the A60 class deck penetration piece, and the analysis results were verified via the fire test. The penetration-piece length, diameter, material type, and insulation density were used as the design factors (DFs), and the output responses were the weight, temperature, cost, and productivity. The quantitative effects of each DF on the output responses were evaluated using the design-of-experiments method. Additionally, an optimum design case was identified to minimize the weight of the A60 class deck penetration piece while satisfying the allowable limits of the output responses. According to the design-of-experiments results, various approximate models, e.g., a Kriging model, the response surface method, and a radial basis function-based neural network (RBFN), were generated. The design-of-experiments results were verified by the approximation results. It was concluded that among the approximate models, the RBFN was able to explore the design space of the A60 class deck penetration piece with the highest accuracy.

Deep-Learning Based Real-time Fire Detection Using Object Tracking Algorithm

  • Park, Jonghyuk;Park, Dohyun;Hyun, Donghwan;Na, Youmin;Lee, Soo-Hong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • In this paper, we propose a fire detection system based on CCTV images using an object tracking technology with YOLOv4 model capable of real-time object detection and a DeepSORT algorithm. The fire detection model was learned from 10800 pieces of learning data and verified through 1,000 separate test sets. Subsequently, the fire detection rate in a single image and fire detection maintenance performance in the image were increased by tracking the detected fire area through the DeepSORT algorithm. It is verified that a fire detection rate for one frame in video data or single image could be detected in real time within 0.1 second. In this paper, our AI fire detection system is more stable and faster than the existing fire accident detection system.

Analysis of Ambulance Traffic Accident During Driving (국내 구급차량의 운행 중 사고 분석에 관한 조사 연구)

  • Shin, Dong-min;Yoon, Byung-gil;Han, Yong-taek
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.130-137
    • /
    • 2016
  • The purpose of this study is to investigate the circumstances surrounding collisions involving ambulances with an aim to improving the safe operation of emergency services. Collisions are relatively common within paramedic emergency services. We analyzed the time, injury site, and any other specific factors of 908 collisions occurring within four cities. Within our study 29.6% of paramedics have been involved in accidents while responding to an emergency call, with the main cause of the accident being signal violation (35.7%), and is the other party's negligence (22.2%). 92.1% of these accidents occurred while the emergency lights were being operated. XX% of accidents took place in the afternoon, while xx% took place within the hours of xx:xx and xx:xx, during which time there is generally lower levels of traffic, which can cause severe brain and neck damage of 14.4% but the other part is 62.1%. (Ed note; this is not clear at all. 14.4% of collisions resulted in severe head and neck injuries, while 23.5% of collisions resulted in no injury. According to the respondents, defensive driving (xx%), observance of traffic laws (xx%), safe driving habits (xx%)to paramedics were the most critical factors in evading collision. Signal passes were identified as the most common cause of collision (70.1%). Although the majority of collisions occurred while the emergency lights were operational, the damage can cause severe damage at the time of accident occurred.

Night fire fighting helicopters operations and Aviation Safety (야간산불진화 헬기 운영과 항공안전)

  • Choi, Youn-Chul
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.22 no.1
    • /
    • pp.145-151
    • /
    • 2014
  • Not only in Korea, but also in other countries, most helicopter accidents occur at low altitude. Analysis on accidents data collected both in Korea and other countries has brought two conclusions. Firstly, helicopter operations during the night hours carries a high risk. Secondly, the most common cause of night hour operations is loss of control due to the flight illusion. As an operation relying on a night vision in particular has a very high accident hazard, accompanying instruments such as NVG are ought to be provided. Hence, a thorough preparation and inspection on missions for night forest fire extinguishing should be required and perfect guidelines/road maps and enough training programs for the operation should be provided before the engagement in missions.