• Title/Summary/Keyword: Fire Accident

Search Result 697, Processing Time 0.031 seconds

Investigation and Theoretical Analysis of a Fire Accident Caused by Smoldering Combustion (Smoldering 연소로 인한 화재사고 조사보고 소개 및 이론적 해석)

  • 김연승;변영철;황정호
    • Fire Science and Engineering
    • /
    • v.13 no.3
    • /
    • pp.3-17
    • /
    • 1999
  • Smoldering is a non-flaming combustion mode, characterized by thermal degradation and c charring of the virgin material, evolution of smoke and emission of visible glow. A big fire may @ occur even in a confined environment having a limited amount of oxygen, due to smoldering c combustion through a porous solid material. This paper presents a theoretical analysis on the effect of smoldering combustion on fire occurrence based on a report about fire investigation of a real f fire accident. It is assumed that the propagation of the smolder wave is one-dimensional, d downward, opposing an upward forced flow and steady in a frame of reference moving with the s smolder wave. Smoldering combustion is modeled by a one-step reaction mechanism, without c considering pyrolysis. It is found that dominant parameters controlling smoldering combustion i include mass flux of oxidizer entering the reaction zone and void fraction of solid fuel. It is also found that the mechanism of transition to flaming is critically influenced by these two parameters.

  • PDF

Electrical fire prediction model study using machine learning (기계학습을 통한 전기화재 예측모델 연구)

  • Ko, Kyeong-Seok;Hwang, Dong-Hyun;Park, Sang-June;Moon, Ga-Gyeong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.6
    • /
    • pp.703-710
    • /
    • 2018
  • Although various efforts have been made every year to reduce electric fire accidents such as accident analysis and inspection for electric fire accidents, there is no effective countermeasure due to lack of effective decision support system and existing cumulative data utilization method. The purpose of this study is to develop an algorithm for predicting electric fire based on data such as electric safety inspection data, electric fire accident information, building information, and weather information. Through the pre-processing of collected data for each institution such as Korea Electrical Safety Corporation, Meteorological Administration, Ministry of Land, Infrastructure, and Transport, Fire Defense Headquarters, convergence, analysis, modeling, and verification process, we derive the factors influencing electric fire and develop prediction models. The results showed insulation resistance value, humidity, wind speed, building deterioration(aging), floor space ratio, building coverage ratio and building use. The accuracy of prediction model using random forest algorithm was 74.7%.

A Study on the Use of Wireless Signals of Mobile Phones for Effective Rescue Activities at Fire Sites (화재 현장에서 효과적인 구조활동을 위한 휴대전화의 무선 신호 활용 방안 연구)

  • Kim, Younghyun;Kim, Boseob;Jung, Jongjin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.235-236
    • /
    • 2021
  • As a result of analyzing the fire accident of the Jecheon complex that occurred at the end of 2017, there have been many casualties due to delays in checking the location information of isolated people. In order to prevent such an accident, various research has been conducted to estimate the location of requesters by means of detecting wireless communication information of mobile phones existing at disaster sites. The main concept is to detect an RF signal of a mobile phone at fire sites and, based on this, precisely estimate the location of the mobile phone on the LOS/NLOS. However, it is difficult to get visibility at fire sites due to smoke and the fire. Therefore, apart from estimating the location of requesters, a research is also needed to determine the direction of entry within fire sites. In this paper, we propose a method to determine a direction of entry to provide effective rescue activities using wireless communication information of mobile phones.

  • PDF

An Analysis on the Accident Influence Factor and Severity of Construction General Workers (건설 보통인부의 안전재해 영향요인 및 재해강도 분석)

  • Shin, Won-Sang;Son, Chang-Baek
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.3
    • /
    • pp.69-76
    • /
    • 2018
  • General workers who assist various technicians in different fields with their work across the whole construction sites without having a particular skill are at risk of the highest accident rate and their accident form becomes varied. Accordingly, this study was conducted to identify the relationship between form of safety accident and influence factor in general workers and analyze accident severity by influence factor. The followings are the results from this study. First, as a result of analyzing major form of accident and influence factors in general workers with network analysis methodology, nine forms of accident and seventeen influence factors were drawn. Second, it was found that in accident severity among general workers, collapsing, among various forms of accident, appeared the highest, followed by fall, electric shock, fire, hit by an object, bumped against, trip, scission getting cut chopped in order. Third, main points of special, concentrated, and permanent management were presented in order to reduce the safety accident in general workers effectively.

A study on the motivation analysis and prevantion of incendiary crime (방화범죄의 동기분석 및 대책에 관한 연구)

  • Kim, Soo-Jin;Kim, Soo-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.207-230
    • /
    • 2010
  • Nowadays, the arson is not common interest happening. the arson has been handled with a crime of violence along with murder, robbery and rape. because of being detrimental to the public clam. but the arson a has not been made award of a serious social problem. There is a rise in the control pos-sibility according to a level of national concern. we have known that the last fire accident of the Dea-gu underground It took a heavy toll of lives and the property due to our no interest in arson. The government should not only make up for legislation and systematize to correct a defect but also there is uniting the countermeasure system of the organs. The government establish particular research institution of the arson to consider a useful countermeasure. a purpose of this study is to enhance the concern and cognition of people and to search for the effective approach on the control of crime arson which is increasing recently.

  • PDF

A Study on the Possibility of Electrical Fires due to the Short Circuit and Ground Fault of Power Cable Supported by an Iron Fence (철제펜스로 지지된 동력배선의 단락.지락에 의한 전기화재 발생 개연성 연구)

  • Kim, Jeong-Hun;Park, Byoung-Ki;Song, Jong-Hyeok;Jung, Ki-Chang
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.6
    • /
    • pp.41-45
    • /
    • 2007
  • Short circuit and ground fault account for the primary causes of electrical fires. In this research, real-scale experiments were conducted to assess the possibility of electrical fires due to these causes. The experiment conditions were identical with an actual fire accident, in which the power cable was supported by an iron fence. The purposes of this research are to investigate the short circuit caused by wire cutting, the conductivity of the iron fence depending on its coating conditions, and the ground fault of one wire or two wires in an effort to reconstruct the fire accident. The test results show that, owing to the instant operation of circuit breaker in the moment of short circuit or ground fault, the generated ignition energy is far less than necessary to start an ignition. Therefore it is concluded that electrical fire is highly unlikely if the electric system is protected by a circuit breaker with normal functions.

Toxic Concentration(T-LOC) Endpoint Distance Study for Fire Brigade Protection in Response to Chemical Accidents (화학사고 초기대응 소방대 보호를 위한 독성농도(T-LOC) 끝점거리 연구)

  • Jong Chan Yun;Chul Hee Cho;Jeong Hun Won
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.6
    • /
    • pp.60-71
    • /
    • 2023
  • The purpose of this study is to propose a quantitative toxicity endpoint distance suitable for the initial response of firefighters by comparing and analyzing the commonly applied toxic level of concern (T-LOC), specifically emergency response planning guidelines (ERPG), acute exposure guideline levels (AEGL), and immediately dangerous to life or health (IDLH). This is to protect the fire brigade, which responds to toxic chemical accidents first during the golden time. Using areal locations of hazardous atmospheres, a damage prediction program, the amount of leakage for both acidic and basic substances, along with the endpoint distance, were analyzed for alternative accident and worst-case accident scenarios. The results showed that the toxicity endpoint distance, serving as a compromise between Level-3 and Level-2 of T-LOC, was longer than ERPG-3 and shorter than ERPG-2 with IDLH, while its values were analyzed in the order of ERPG-2, AEGL-2, IDLH, AEGL-3, and ERPG-3. It is suggested that the application of IDLH in an emergency (red card) and ERPG-2 endpoint distance in a non-emergency (non-red card) can be utilized for the initial response of the fire brigade.

An Accident Investigation of Fire and Explosion Case During Painting Work in the Tank of the Crude Oil Carrier (선박 탱크 내부 도장작업 중 발생한 화재·폭발 사고원인 분석)

  • Ahn, Byung-Joon;Jung, Ki-Hyuk;Rhim, Jong-Kuk
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.20-31
    • /
    • 2018
  • There was an amazing growth in the korean shipbuilding industry considering the industrial magnitude and the technical level. On the contrary of the growth, there are a number of accidents in the shipbuilding yard. According to the statistic data of the industrial accident in the last 7 years, the number of accidental fatalities in shipbuilding industries are 1.48 ‱ which are over more than doubles of the average in the Korean industries, 0.66 ‱. Thus, through an accident investigation of fire and explosion case during painting work in the tank of the crude oil carrier, it have been tried to diagnose actual conditions in the shipbuilding yards.

Investigation of the LPG Gas Explosion of a Welding And Cutting Torch at a Construction Site

  • Lee, Su-kyung;Lee, Jung-hoon;Song, Dong-woo
    • Korean Chemical Engineering Research
    • /
    • v.56 no.6
    • /
    • pp.811-818
    • /
    • 2018
  • A fire and explosion accident caused by a liquefied petroleum gas (LPG) welding and cutting torch gas leak occurred 10 m underground at the site of reinforcement work for bridge columns, killing four people and seriously injuring ten. We conducted a comprehensive investigation into the accident to identify the fundamental causes of the explosion by analyzing the structure of the construction site and the properties of propane, which was the main component of LPG welding and cutting work used at the site. The range between the lower and upper explosion limits of leaking LPG for welding and cutting work was examined using Le Chatelier's formula; the behavior of LPG concentration change, which included dispersion and concentration change, was analyzed using the fire dynamic simulator (FDS). We concluded that the primary cause of the accident was combustible LPG that leaked from a welding and cutting torch and formed a explosion range between the lower and upper limits. When the LPG contacted the flame of the welding and cutting torch, LPG explosion occurred. The LPG explosion power calculation was verified by the blast effect computation program developed by the Department of Defense Explosive Safety Board (DDESB). According to the fire simulation results, we concluded that the welding and cutting torch LPG leak caused the gas explosion. This study is useful for safety management to prevent accidents caused by LPG welding and cutting work at construction sites.

A Study on the Improvement of Hazardous Materials Accident Report for Chemical Safety Management (화학물질 안전관리를 위한 위험물 사고 발생보고서 개선연구)

  • Goh, Moon-Soo;Jang, Hyeon-Jun;Seong, Chun-Mo;Lee, Hunggi;Lee, Bong-Woo;Shin, Dong-il
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.1
    • /
    • pp.41-49
    • /
    • 2022
  • Chemicals are widely used throughout society, and usage is expected to increase in the future. As a result, various accidents related to chemicals and dangerous substances are occurring, and the frequency of occurrence is expected to continue to increase. Thus, it is expected that this study will present problems and improvement directions through analysis of each associated agency's accident report and management system, and improve the research input system to increase efficiency in collecting and statistical calculation of chemical and hazardous accident.