Application of Signal Pattern Recognition Technique of Digital Wireless Fire Alarm System (디지털 방식 무선 화재알림설비의 신호 패턴 인식기법 적용)

  • Park, Seunghwan;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.5
    • /
    • pp.14-21
    • /
    • 2022
  • The purpose of this study was to apply the signal pattern recognition technique to the digital wireless fire-alarm system and to reduce unwanted fire alarms. In this study, the fire alarms of the K Institute, which operates the largest digital wireless fire-alarm system in Korea, were classified into normal operations and unwanted fire alarms, and these were analyzed and compared with actual fire signals. In addition, by designing a non-fire signal filter and applying it to the K Institute, we confirmed that the monthly unwanted fire alarm rate of all 5,713 detectors decreased sharply. In particular, the unwanted fire alarm rate for flame decreased from 1.09% to 0.11% and the unwanted fire alarm rate for smoke decreased from 0.65% to 0.035%.

A Study on the Analysis of Fire Risk according to the Operation Scenario of Fire Safety Equipment (화재안전설비 작동 시나리오에 따른 화재위험분석에 관한 연구)

  • Jin, Seung-Hyeon;Koo, In-Hyuk;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.139-140
    • /
    • 2022
  • This study aims to present basic data for fire risk assessment. In the existing fire risk assessment, the operation of fire safety facilities is not considered. In addition, there is a lack of data on the fire growth rate to predict the spread of fire. Therefore, this study intends to build a fire scenario using fire statistics data. In addition, the fire growth rate is to be derived in consideration of the floor area of burnout and the cause of fire.

  • PDF

A Study on Fire Scenario Analysis Based on Fire Statistics for Building Fire Risk Analysis (건축물 화재위험평가를 위한 화재통계 기반 화재시나리오 분석에 관한 연구)

  • Jin, Seung-Hyeon;Kim, Hye-Won;Koo, In-Hyuk;Kwon, Yeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.81-82
    • /
    • 2022
  • This study aims to establish a methodology for rational fire risk assessment for building evacuation safety in case of fire, and specifically, to propose a fire risk assessment technique using fire scenarios considering various uncertain factors in case of fire. In order to analyze the extent to which the assumed conditions can occur, that is, the probability of each accident caused by fire, the safety rate is analyzed according to the presence or absence of each factor by using fire statistics. Factors related to the fire protection performance and evacuation ability of buildings are defined as disaster factors. In this study, disaster factors were classified into the following three categories.

  • PDF

Statistics and Management Systems of Unwanted Domestic and Foreign Fire Alarms (국내·외 비화재보의 통계 및 관리체계에 관한 연구)

  • Hwang, Euy-Hong;Lee, Sung-Eun;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.30-40
    • /
    • 2020
  • In the event of a fire and a disaster, prompt and accurate alarms inside and outside the building are directly related to the minimization of damage and the success of life evacuation. However, due to unwanted fire alarms in automated fire detection systems, the number of dispatches by misunderstanding in the 119 service is increasing. This causes the insensitivity to the safety of building managers and the waste of the fire-fighting power. Therefore, in this study, the statistical databases and literature on unwanted fire alarms in Korea and abroad (USA, UK) were identified and the management systems for unwanted fire alarms were compared and analyzed to identify problems of statistics in the management systems for unwanted fire alarms.

A Study on the Fire Resistance Design of Buildings Considering the Fire Load Energy Density (화재하중밀도를 고려한 건축물의 내화설계법에 관한 연구)

  • 이평강;이용재;최인창;김회서
    • Fire Science and Engineering
    • /
    • v.17 no.2
    • /
    • pp.10-16
    • /
    • 2003
  • The main purpose of this study is to raise the point at issue and to propose reform direction about the current performance criteria of fire resistance through the examination of the fire resistance required for each use of compartment by using performance-based fire safety design method. To examine the performance criteria of fire resistance, this study compared the equivalent time of fire exposure which was calculated by using time-equivalent formulae with the required fire resistance time determined by existing prescriptive code, and surveyed factors such as the fire load energy density, ventilation factor, fire compartment materials and fire compartment geometry in order to calculate the equivalent time of fire exposure.

A New Approach to Statistical Analysis of Electrical Fire and Classification of Electrical Fire Causes

  • Kim, Doo-Hyun;Lee, Jong-Ho;Kim, Sung-Chul
    • International Journal of Safety
    • /
    • v.6 no.2
    • /
    • pp.17-21
    • /
    • 2007
  • This paper aims at the statistical analysis of electrical fire and classification of electrical fire causes to collect electrical fires data efficiently. Electrical fire statistics are produced to monitor the number and characteristics of fires attended by fire fighters, including the causes and effects of fire so that action can be taken to reduce the human and financial cost of fire. Electrical fires make up the majority of fires in Korea(including nearly 30% of total fires according to recent figures), The incorrect and biased knowledge for electrical fires changed the classification of certain types of fires, from non-electrical to electrical. It is convenient and required to develop the standardized form that makes, in the assessment of the cause of electrical fires, the fire fighters directly ticking the appropriate box on the fire report form or making an assessment of a text description. Therefore, it is highly recommended to develop electrical fire cause classification and electrical fire assessment on the fire statistics in order to categorize and assess electrical fires exactly. In this paper newly developed electrical fire cause classification structure, which is well-defined hierarchical structure so that there are not any relationship or overlap between cause categories, is suggested. Also fire statistics systems of foreign countries are introduced and compared.

A Study on the Modeling of Vertical Spread Fire of Exterior Panel by Fire Dynamic Simulation (FDS) (FDS를 이용한 외장재의 수직 확산 화재의 모델링에 관한 연구)

  • Min, Seh-Hong;Yoon, Jung-En
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.2
    • /
    • pp.77-85
    • /
    • 2009
  • Considering heat insulation and beautiful sight of construction, making use of exterior panels is increasing. Recently the exterior panels now are weak very much, and so in consequence of the weakness fire spreads rapidly. Compared with internal fire, external vertical fire spread rate goes rapidly and it is extensive in spread range, therefore it is dangerous very much. Accordingly, under present condition of poor standard of exterior panels, it is required to take measure to meet the appropriate situation. In this study, by making use of FDS(Fire Dynamic Simulation) program about external vertical fire of high rise building, fire behavior is searched by computer. It is important that realizing by computer fire modeling about external vertical fire must be included certainly in procedure of fire performance design in the future. In modeling program, FDS version 5 is available, and aluminium composite panel is applied in external panels. In this study, for realizing of actual fire condition, FDS is applied by details of fire scenarios considering influence of wind.

Analysis on the Implementation Status of Domestic PBD (Performance Based Design) - Focusing on the Fire Scenario and Simulation (국내 성능위주설계의 시행현황 분석 - 화재시나리오 및 시뮬레이션을 중심으로)

  • An, Sung-Ho;Mun, Sun-Yeo;Ryu, Ill-Hyun;Choi, Jun-Ho;Hwang, Cheol-Hong
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.32-40
    • /
    • 2017
  • The current status of Performance-Based Design (PBD) implemented in 4 wide areas (Seoul, Gyeonggi, Incheon and Busan) over the past 5 years was reviewed with regard to the number of PBD implementation and target buildings. Then, detailed status related to fire scenarios, input information for fire simulation, and grid size were analyzed with the pre-review for the PBD. As a result, the domestic PBD was mainly applied to the mixed occupancy. In the fire simulations performed on the identical fire scenario and fire space, the maximum heat release rate (HRR) varied significantly depending on the PBD designer. Various combustibles were also considered for the identical fire source, and their combustion properties also showed considerable uncertainty. In addition, the applicability of accurate input information for predictive models of heat and smoke detectors was examined. Finally, the average grid size for the fire simulation using Fire Dynamics Simulator (FDS) was analyzed, and the improvement of PBD to minimize designer dependency was proposed.

Research about Improvement Way of Fire Investigation System - Regarding Product Liability Responsibility Law - (화재조사 제도의 개선방안에 관한 연구 - 제조물 책임법과 관련하여 -)

  • Mun, Yong-Soo;Kong, Ha-Sung;Yoon, Myong-O
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.105-111
    • /
    • 2008
  • Improvement of fire investigation system is required to supplement problem that can happen after product liability law enforcement of our country. This treatise searches special quality of inside and outside of the country fire investigation that was enforced present with theoretical background of manufacture water responsibility law and compared. And is based and grasped objective and hangup in police fire investigation, fire fighting fire investigation, engine fire investigation of private fire judgment. By improvement way accordingly first, proposed fire emotion connection studies and establishment and connoisseurship qualification system establishment etc. in the common people private fire diet, judgment, analysis company's necessity second, fire fighting of fire investigation system, police's member anger third, college.

A Study on fire risk in an enclosure room (밀폐공간에서의 화재 위험성에 관한 연구)

  • Kim, Soo-Young;Kim, Hong-Sik;Han, Dong-Hun;Lee, Sung-Ryoun;Kim, Joo-Seok;Yuk, Geun-Hwan;Chon, Sung-Soo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.449-453
    • /
    • 2009
  • 기존 주택 및 고층건물화재에서 발생하는 화재 폭발 사고에 대해서는 많은 연구가 이루어지고 있으나, 이천 냉동창고 화재와 같이 많은 인명피해가 발생되는 작업환경에서의 화재 특히 밀폐공간에서의 화재 폭발 위험성 및 특성은 주택 및 고층건물화재에 비교하여 높은 폭발위험성 및 빠른 화염전파 특성을 보이나 이에 관한여 구체적인 연구는 미비한 실정이다. 본 연구는 밀폐공간 작업환경에서의 화재 폭발 위험성 특성 분석을 위하여 밀폐공간에서 작업 시 발생되어지는 가연성 가스의 확산 특성 분석 및 폭발 위험성 분석 방법에 관한 연구와 밀폐공간에서의 화염 확산 특성에 관한 연구논문 이다.

  • PDF