• Title/Summary/Keyword: Finite difference element

Search Result 1,024, Processing Time 0.029 seconds

A Study on High Frequency Induction Hardening of S45C Specimen by FEA and Experiment (유한요소해석 및 실험에 의한 S45C 시편의 고주파 유도경화에 관한 연구)

  • Park, Kwan-Seok;Choi, Jin-kyu;Lee, Seok-Soon
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.5
    • /
    • pp.1-7
    • /
    • 2018
  • In this study, we proposed a high frequency induction hardening analysis method based on electromagnetic-thermal co-simulation. In the high frequency induction heating analysis, the results of the finite element analysis (FEA) (considering the change of the material property and the cooling factor according to the temperature) and those of the high frequency induction hardening experiment (using the S45C specimen) were compared. The hardness of the S45C specimens was measured using the micro Vickers hardness test to determine the depth of hardening. The measurement results were then compared with the results of FEA. The result of high frequency induction heating analysis showed that the temperature was more than $750^{\circ}C$, which is the A2 transformation point of S45C, while the temperature during quenching was below $200^{\circ}C$. The results showed that the difference of the depth of hardening between the FEA and the experiment is 0.2mm.

Dynamic Bearing Pressure of Inverted T-type Retaining Walls Subjected to Seismic Motion (지진시 동토압을 받는 역 T형 옹벽의 접지압 산정에 관한 연구)

  • Lee, Jin-Sun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.35-45
    • /
    • 2012
  • Pseudo static analysis using the Mononobe-Okabe method and numerical analysis considering a small strain nonlinearity from the soil were performed to determine the bearing pressure changes of the inverted T-type retaining wall subjected to earthquake motions. In many cases, an inverted 'T' type retaining wall of more than 10 m shows bearing capacity failure under earthquake conditions, despite showing sufficient bearing capacity during normal conditions. The most important reason for this is the change of the effective base area during an earthquake. In this paper, the change of the effective base area of an inverted 'T' type wall is analyzed by using finite difference element code (FLAC). In addition, the effect of dynamic bearing capacity coefficients (which has been suggested by several researchers but not adopted in current design codes and procedures) was verified.

Prediction of Differential Drying Shrinkage in Concrete (콘크리트의 부등건조수축에 관한 연구)

  • 김진근;이칠성
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.2
    • /
    • pp.153-161
    • /
    • 1997
  • In the concrete st~uctures exposed to the environmental condition, the water movement is occurred by thc moisture difilsion, and the rnoisturrt distribution in concwt.c is nonunifhrm. Such a non-unif'orm moisture distribution causes tht. diflbrent.ia1 drying shrinkage in concrete structures. From this typc. of' dif'fercntial drying shrinkagr' tensiit-1 stress is occurred in exposure surface of concrete structures. and may result in crack formation. This residual stress is significantly affected by the creep of concrete, and the differential creep is also occurred at the cross section of concrete structures due to moisture difference at each locations. In this study, based on the moisture diffusion theory, a finite element program which is capable of simulating the moisture distribution in concrete was developed. And the analysis method for the differential drying shrinkage was suggested, in which the differential creep was considered. The differential drying shrinkage strain was also measured at various positions of concrete. Finally the validity of analysis method was proved by comparing test results with analytical results.

A Study on Earth Pressure Calculating Method about Shield TBM Tunnel Segments in the Rock (암반층에서 쉴드 TBM 터널 세그먼트의 작용하중 산정방법에 관한 연구)

  • Chun, Byungsik;Ki, Jungsu;Kang, Taehee;Kwag, Yunehyeong;Byun, Yoseph
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.5
    • /
    • pp.13-21
    • /
    • 2014
  • This study analyzed the differences in the analysis techniques through a comparative analysis of the various segment's modeling techniques of Shield TBM method and proposed reasonable modeling techniques. Also, this study suggested reasonable estimating methods of load to be applicable in the field through the load analysis and three-dimensional finite element analysis by estimating model of rock mass relaxation load. Estimating method of relaxation area by rock mass rating makes no odds of output in subgrade with high rock mass rating, but so the difference of output is large, that is judged to set conservative design off. In estimating result of rock mass relaxation area by three-dimensional analysis relaxation area of subgrade with low-grade soil was predicted to be positioned at medium-range of many methods, in case of designing segment in subgrade with low-grade soil it needs to actively review estimation of relaxation area through three-dimensional analysis reflecting mechanical tunnel excavation.

Three dimensional finite element analysis of the fully bone anchored bridge and implant-supported overdenture in edentulous mandible (무치하악에서 임플랜트를 이용한 고정성 및 가철성 보철물의 삼차원 유한요소 분석)

  • Lim, Heon-Song;Cho, In-Ho;Lim, Ju-Hwan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.4
    • /
    • pp.251-276
    • /
    • 2002
  • The purpose of this study was to compare and analyze the stress distribution and displacement of the fully bone anchored bridge and implant-supported overdenture in edentulous mandible on certain conditions such as number of implants, different design of superstructure. Three dimensional analysis was used and nine kinds of models designed for this study. FEM models were created using commercial software[$Rhinoceros^{(R)}$ (Ver. 1.0 Robert McNeel & Associates, USA)], and analyze using commercial software [Cosmos/$Works^{TM}$(Ver. 4.0 Structural Research & Analysis Corp., US A)]. A vertical load and $45^{\circ}$ oblique load of 17kgf were applied at the left 1st. molar. The results were as follows : (1) In the group of OVD, the displacement was reduced as increasing the number of fixture under vertical loading but there was no specific difference in Von Mises stress. Under oblique loading, the displacement was same at the vertical loading but Von Mises stress was reduced in order of OVD-3, OVD-4, OVD-2. But, bending moment reduced according to increasing the number of fixture. (2) In the group of FBAB, under vertical and oblique loading, the magnitude of Von Mises stress and displacement reduced according to increasing the number of fixtures. FBAB-4 and FBAB-5 showed similar score and distribution, but FBAB-6 showed lower value relatively. (3) In cantilever design, the maximum displacement reduced under vertical loading but increased under oblique loading. However, von mises stresses on fixtures increased under vertical and oblique loading. (4) In comparing OVD-group with FBAB-group, FBAB showed low magnitude of displacement in respect of oblique loading. However OVD-group was more stable in respect of stress distribution.

A New Evaluation Method for Interfacial Properties of Composites using the Gradual Multi-Fiber Fragmentation Test (단계적 다섬유 Fragmentation 시험법을 이용한 복합재료의 계면적 특성에 대한 새로운 평가방법)

  • ;;Koichi Goda
    • Composites Research
    • /
    • v.12 no.2
    • /
    • pp.10-25
    • /
    • 1999
  • A new evaluation method for the interfacial properties of fibrous composites based on a fragmentation technique is proposed by using the gradual multi-fiber composite, in which the inter-fiber spacing is gradually changed. The results showed that as the inter-fiber distance increased, the aspect ratio of broken fibers decreased while the interfacial shear strength between the fiber and matrix increased. When the reciprocal of the inter-fiber destance was taken for the above relations, both the aspect ratio and interfacial shear strength showed a saturated value. This means that the gradual multi-fiber composite indicates an upper bound in aspect ratio and an upper bound in interfacial shear strength. It was concluded that this fragmentation test could be a new method for composite evaluation, since reducing a difference between these two bounds is effective for composite strengthening. In addition an elastoplastic finite element analysis was carried out to relate the above results with fiber stress a distribution around fiber breaks. It was proved that the bound obtained in the gradual multi-fiber composite test is closely related to stress concentrations caused by a group of multi-fiber breaks.

  • PDF

A study on the vibration characteristics of carbon/epoxy propeller shaft (카본/에폭시 복합재로 제작된 수송기계용 추진축의 진동특성에 관한 연구)

  • 여운기;김희송;공창덕;정종철
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.5 no.4
    • /
    • pp.31-39
    • /
    • 2001
  • Composite propeller shafts for a vehicle have major advantages such as reduction of vibration, noise, and weight. A propeller shaft was designed with a carbon/epoxy composite material using the finite element method(FEM), and prototype shafts for tests were manufactured by the filament winding manufacturing process. In order to verify the design procedure by FEM, Two kinds of experimental tests were carried out using a FFT analyzer with impact hammers and a critical speed measuring apparatus for measurement of natural frequencies and critical speeds. The difference between the FEM analysis result and the test result was less than 3.4%, showing FEM analysis results to be acceptable. The parametric study was focused on determining the factor affecting the vibration and strength characteristics of the propeller shaft based on FEM. In investigation of the change in natural frequency without an increase in propeller shaft weight, it was found that the winding angle is the most significant factor affecting the vibration and strength characteristics.

  • PDF

Fluid-Structure Interaction Analysis on the Deformation of Simplified Yacht Sails (단순형태 세일의 변형에 대한 유체-구조 연성 해석)

  • Bak, Sera;Yoo, Jaehoon;Song, Chang Yong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.50 no.1
    • /
    • pp.33-40
    • /
    • 2013
  • Since most of yacht sails are made of thin fabric, they form cambered sail shape that can efficiently generate lift power by aerodynamic interaction and by external force delivered from supporting structures such as mast and boom. When the incident flow and external force alter in terms of volume or condition, the shape of sail also change. This deformation in shape has impact on the peripheral flow and aerodynamic interaction of the sail, and thus it is related to the deformation of the sail in shape again. Therefore, the precise optimization of aerodynamic performance of sail requires fluid-structure interaction (FSI) analysis. In this study, the simplified sail without camber was under experiment for one-way FSI that uses the result of flow analysis to the structural analysis as load condition in an attempt to fluid-structure interaction phenomenon. To confirm the validity of the analytical methods and the reliability of numerical computation, the difference in deformation by the number of finite element was compared. This study reproduced the boundary conditions that sail could have by rigs such as mast and boom and looked into the deformation of sail. Sail has non-linear deformation such as wrinkles because it is made of a thin fabric material. Thus non-linear structural analysis was conducted and the results were compared with those of analysis on elastic material.

Comparative Study for dry-wet Treatment Effect in a Tidal Hydrodynamic Simulation (조석수동역학 모의에서 조간대 침수-노출 고려효과 비교연구)

  • 서승원;김정훈
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.15 no.2
    • /
    • pp.97-107
    • /
    • 2003
  • In order to evaluate the effect of dry-wet treatment on well developed tidal flats along the complex coastal line in the western part of Korean Peninsula, we adopted a finite element tidal hydrodynamic simulation model, ADCIRC incorporating newly suggested dry-wet option and applied it to Chonbuk coastal area and Keum river estuary. Model comparison with observed current data by RMS error in the Chonbuk area shows very good agreement within 1cm/sec of tidal velocity difference and 3% of error to maximum tidal currents. However there is not seen any significant advantages in dry-wet treatment. For the tidal volume tests in the Keum river estuary, the differences are satisfied within 5% nevertheless of dry-wet treatment but in a near cross section it marks over 20%. However both results are almost same in tidal residual tests. Thus it can be concluded that dry-wet option is not always necessary in the simulation of long-term dispersion analysis.

Stiffness Modulus Comparison in Trackbed Foundation Soil

  • Kim, Daesung;Cho, Hojin;Park, Jaebeom;Lim, Yujin
    • International Journal of Railway
    • /
    • v.8 no.2
    • /
    • pp.50-54
    • /
    • 2015
  • The primary function of the trackbed in a conventional railway track system is to decrease the stresses in the subgrade to be in an acceptable level. A properly designed trackbed layer performs this task adequately. Many design procedures have used assumed and/or are based on critical stiffness values of the layers obtained mostly in the field to calculate an appropriate thickness of the sublayers of the trackbed foundation. However, those stiffness values do not consider strain levels clearly and precisely in the layers. This study proposes a method of computation of stiffness that can handle with strain level in the layers of the trackbed foundation in order to provide properly selected design values of the stiffness of the layers. The shear modulus values are dependent on shear strain level so that the strain levels generated in the subgrade in the trackbed under wheel loading and below plate of Repeated Plate Bearing Test (RPBT) are investigated by finite element analysis program ABAQUS and PLAXIS programs. The strain levels generated in the subgrade from RPBT are compared to those values from RC (Resonant Column) test after some consideration of strain levels and stress consideration. For comparison of shear modulus G obtained from RC test and stiffness moduli $E_{v2}$ obtained from RPBT in the field, many numbers of mid-size RC tests in laboratory and RPBT in field were performed extensively. It was found in this study that there is a big difference in stiffness modulus when the converted $E_{v2}$ values were compared to those values of RC test. It is verified in this study that it is necessary to use precise and increased loading steps to construct nonlinear curves from RPBT in order to get correct $E_{v2}$ values in proper strain levels.