• Title/Summary/Keyword: Finger-type

Search Result 318, Processing Time 0.029 seconds

Lycopersicon Eculentum C2H2-type Zinc Finger Protein Induced by Oxidative Stress Especially

  • Seong, Eun-Soo;Lee, Ji-Yeon;Yu, Chang-Yeon;Yang, Deok-Chun;Eom, Seok-Hyun;Cho, Dong-Ha
    • Journal of Plant Biotechnology
    • /
    • v.34 no.3
    • /
    • pp.167-172
    • /
    • 2007
  • A tomato zinc-finger protein gene, LeZFP1, encoding the Cys2/His2-type zinc-finger transcription factor was searched from cDNA microarray analysis of gene expression following induction of the overexpressed tomato transgenic plants showing resistance for pathogen and abiotic stresses. The full-length cDNA of LeZFP1 encoded a protein of 261 amino acid residues. Analysis of the deduced amino acid sequence of LeZFP1 revealed that it shares high sequence identity with pepper CAZFP1 (81% identity). We found that single copy of LeZFP1 gene is present in the tomato genome through southern blot analysis. The LeZFP1 transcripts were constitutively expressed in the tomato mature and young leaves, but were detectable weakly in the flower, stem and root. The LeZFP1 transcripts were significantly reduced in treated leaf tissues with NaCl and mannitol. The LeZFP1 gene was induced by oxidative stress especially. Our results indicated that LeZFP1 may play a role function involved in oxidative stress signaling pathways.

Analysis and Isolation of Walking-type Cultivator Vibration Transmitted to Operator′s Hands (손으로 전달된 관리기 진동의 분석과 방진대책)

  • 박영준;김경욱
    • Journal of Biosystems Engineering
    • /
    • v.27 no.4
    • /
    • pp.273-282
    • /
    • 2002
  • This study was intended to measure and analyze hand-transmitted vibrations from cultivator in idle and operation modes for three different types of field works. Based on this analysis a time for the white finger syndrome to appear on 10% of the operators was estimated assuming that their daily exposure is 3 hours. The 4 methods to reduce the hand vibration were also proposed and compared with each other. The results of the study were summarized as follows : The highest vibration level was recorded during trenching operation, resulting in a total average vibration of 11.5 m/s$^2$. Followings were 7.6 m/s$^2$ during rotary tillage and 7.0 m/s$^2$ for weeding. When exposed to these levels of vibrations three hours a day, the white finger syndrome is likely to appear in 4 years for trenching, 6.2 years for rotary tillage and 6.8 years for weeding operations. Isolation of hand vibration performed by a rubber pad, anti-vibration gloves, a handle anti-vibration device and engine mounts were respectively 15.7%, 16.5%. 26.1% and 27.0%, resulting in most effective methods of the handle anti-vibration device and engine mounts. A better performance of about 33.9% was achieved when both the handle anti-vibration device and engine mounts were used.

Leiomyoma of Finger: A Case Report (젊은 여성의 수지에 발생한 평활근종: 증례 보고)

  • Kim, Jin Young;Kwon, Oh Jin;No, Ji Hyun
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.19 no.1
    • /
    • pp.33-36
    • /
    • 2013
  • Leiomyoma is a benign solitary tumor which is originated from a smooth muscle cell and grows slowly. It is most commonly found in the uterus and can develop anywhere that smooth muscle is present, including esophagus, lower extremity, stroma of GI tract, and pleura. However, the occurrence of leiomyoma in the hand is so uncommon. We present one case of solid type leiomyoma found in the right $4^{th}$ finger of a young woman.

Design of a Humanoid Robot Hand by Mimicking Human Hand's Motion and Appearance (인간손의 동작과 모양을 모방한 휴머노이드 로봇손 설계)

  • Ahn, Sang-Ik;Oh, Yong-Hwan;Kwon, Sang-Joo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.1
    • /
    • pp.62-69
    • /
    • 2008
  • A specialized anthropomorphic robot hand which can be attached to the biped humanoid robot MAHRU-R in KIST, has been developed. This built-in type hand consists of three fingers and a thumb with total four DOF(Degrees of Freedom) where the finger mechanism is well designed for grasping typical objects stably in human's daily activities such as sphere and cylinder shaped objects. The restriction of possible motions and the limitation of grasping objects arising from the reduction of DOF can be overcome by reflecting a typical human finger's motion profile to the design procedure. As a result, the developed hand can imitate not only human hand's shape but also its motion in a compact and efficient manner. Also this novel robot hand can perform various human hand gestures naturally and grasp normal objects with both power and precision grasping capability.

A Case of Herpetic Whitlow of Toe Misdiagnosed as Bacterial Infection: A Case Report (세균성 감염으로 오인된 발가락의 헤르페스 손끝염: 증례 보고)

  • Ye Rang Jeong;Young Sik Yoon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.28 no.2
    • /
    • pp.68-70
    • /
    • 2024
  • Finger infections are a common problem often caused by viruses, bacteria, or fungi. Similarly, toe infections can present with similar clinical symptoms. Prompt identification of the cause of an infection is crucial for preventing disease progression to a state necessitating immediate and appropriate medical or surgical intervention. Herpetic whitlow is characterized by erythema and painful, non-purulent vesicles and typically results from a herpes simplex virus type 1 or 2 finger infections. However, while herpes whitlow of a finger is common, cases involving a toe are rare. Consequently, a lack of experience of herpetic whitlow of the toe could lead to a misdiagnosis as a bacterial infection and potentially result in unnecessary surgical treatment. Herein, we present a case of herpetic whitlow affecting a great toe that was initially misdiagnosed as a bacterial infection and subsequently treated surgically.

Finger Counting Algorithm in the Hand with Stuck Fingers (붙어 있는 손가락을 가진 손에서 손가락 개수 알고리즘)

  • Oh, Jeong-su
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.10
    • /
    • pp.1892-1897
    • /
    • 2017
  • This paper proposes a finger counting algorithm for a hand with stuck fingers. The proposed algorithm is based on the fact that straight line type shadows are inevitably generated between fingers. It divides the hand region into the thumb region and the four fingers region for effective shadow detection, and generates an edge image in each region. Projection curves are generated by appling a line detection and a projection technique to each edge image, and the peaks of the curves are detected as candidates for finger shadows. And then peaks due to finger shadows are extracted from them and counted. In the finger counting experiment on hand images expressing various shapes with stuck fingers, the counting success rate is from 83.3% to 100% according to the number of fingers, and 93.1% on the whole. It also shows that if hand images are generated under controlled conditions, the failure cases can be sufficiently improved.

Experimental Study of the End-plate Gap Effect on the Performance of Extended End-plate Type Splice (이음면 이격이 확장형 단부판 이음부 성능에 미치는 영향에 대한 실험적 연구)

  • Kim, Cheol Hwan;Lee, Myung Jae;Kim, Hee Dong;Kim, Sa Bin
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.6
    • /
    • pp.427-438
    • /
    • 2016
  • This study is experimental research for the effect of gap at the end plate on the performance of extended end-plate type splice. For this research, simple beam type specimens by using extended end-plate type splice are planned. Main variables are the initial gap between end-plates, the installation of finger shim plate before the installation of high tension bolts, the final gap between end-plates, and the installation of finger shim plate after the installation of high tension bolts. The static loading tests results show that the maximum bending strength of splice is not dependent on the gap, but the vertical displacement, initial stiffness and elastic stiffness are affected by the gap. In addition to that, the possibility of brittle fracture is increased when the torque of high tension bolt is used to control the gap. Thus, careful consideration is needed in this case.

Application of OLED as the Integrated Light source for the Portable Lab-On-a-Chip (휴대형 랩온어칩을 위한 집적화 광원으로의 OLED 적용)

  • Kim, Ju-Hwan;Shin, Kyeong-Sik;Kim, Young-Min;Kim, Yong-Kook;Yang, Yeun-Kyeong;Kim, Tae-Song;Kang, Ji-Yoon;Kim, Sang-Sig;Ju, Byeong-Kwon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.193-197
    • /
    • 2004
  • The organic light emitting diode (OLED) is proposed as the novel source in the microchip because it has ideal merits (various wavelengths, thin-film structure and overall emitting) for the integration. In this paper, we fabricated the finger-type pin photodiodes for fluorescence detection and the advanced microchip with OLED integrated pn the microchannel. The finger-type in the diode design extended the depletion region and reduced the internal resistance about 31.2% than rectangular-type. The photodiodes had a 100pA leakage current and a 8720 sensitivity $(I_{Light}/I_{Dark})$ at -1 V bias. The interference filter with 32 layers ($SiO_2$, $TiO_2$) was directly deposited on the photodiode. The OLED was fabricated on the ITO coated glass and was bonded with LOC. The application of thin-film OLED increased the excitation efficiency and simplified the integration process extremely. The prototype device of this application had a superior sensitivity of 100nM-LOD in the fluorescence detection.

  • PDF

A Solitary Neurofibroma of the Small Finger Associated with Trauma

  • Choi, Hwan Jun;Jung, Kyu Hwa;Nam, Doo Hyun
    • Archives of Reconstructive Microsurgery
    • /
    • v.22 no.2
    • /
    • pp.78-81
    • /
    • 2013
  • Neurofibroma may present as a solitary lesion or as multiple lesions. Although there is no site of predilection for solitary lesions, occurrence on the hand is rare. Plexiform neurofibroma can develop in isolation or more commonly as a part of neurofibromatosis type 1. In those that apper in isolation, trauma has been suggested as a precipitating factor. A 68-year-old male farmer had experienced repetitive prior episodes of trauma in the involved finger. He presented with a painless mass on the dorsal aspect of the fifth finger. Physical examination showed a protruding mass measuring approximately $15{\times}20mm$ which was not tenderness to palpation and any skin changes or pigmentation. Ultrasonography showed a cystic mass on the dorsal aspect of the middle phalanx. Microsurgical dissection was applied in order to seperated the lesion from the ulnar side of the dorsal branch of the digital nerve. Pathologic examination of the specimens revealed neurofibroma. At three-month follow-up, motor and sensory function were intact, and range of motion was fully recovered. Traumatic solitary neurofibroma is a rare tumor of the hand, especially in the finger. Hand surgeons should be aware of the diagnostic possibilities of this tumor based on examination, history taking and imaging studies.

  • PDF

A High Resolution Capacitive Single-Silicon Microaccelerometer using High Amplitude Sense Voltage for Application to Personal Information System (고 감지 전압을 이용한 개인 정보기기용 고정도 정전용량형 단결성 실리콘 가속도계)

  • Han, Ki-Ho;Cho, Young-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.53-58
    • /
    • 2001
  • This paper presents a high resolution capacitive microaccelerometer for applications to personal information systems. We reduce the mechanical noise level of the microaccelerometer by increasing the proof-mass based on deep RIE process. We reduce the electrical noise level by increasing the amplitude of an AC sense voltage. The high sense voltage is obtained by DC-to-DC voltage multiplier. In order to solve the nonlinearity problem caused by the high sense voltage, we modify the conventional comb electrode of straight finger type into that of branched finger type, resulting in self force-balancing effects for enhanced detection linearity. The proposed branched finger capacitive microaccelerometer was fabricated by the deep RIE process of an SOI wafer. The fabricated microaccelerometer reduces the electrical noise at the level of $2.4{\mu}g/\sqrt{Hz}$ for the sense voltage of l6.5V, which is 10.1 times smaller than the electrical noise level of $24.3{\mu}g/\sqrt{Hz}$ at 0.9V. For the sense voltage higher than 2V, the electrical noise level of the microaccelerometer became smaller than the constant mechanical noise level of $11{\mu}g/\sqrt{Hz}$. Total noise level, including the electrical noise and the mechanical noise, has been measured as $9{\mu}g/\sqrt{Hz}$ for the sense voltage of 16.5V, which is 3.2 times smaller than the total noise of $28.6{\mu}g/\sqrt{Hz}$ for the sense voltage of 0.9V. The self force-balancing effect results in the increased stiffness of 1.98 N/m at the sense voltage of 17.8V, compared to the stiffness of 1.35 N/m at 0V, thereby generating the additional stiffness at the rate of $0.002N/m/V^{2}$.

  • PDF