• 제목/요약/키워드: Finger length

검색결과 152건 처리시간 0.022초

젊은 여성의 몸통 근육 활성도 분석을 통한 목발 길이 측정 방법의 효율성 비교 (Comparison of the Effects of Different Crutch Length Measurement Methods on Trunk Muscle Activities in Young Females)

  • 전현;오덕원
    • 대한물리의학회지
    • /
    • 제15권1호
    • /
    • pp.77-84
    • /
    • 2020
  • PURPOSE: This study compared the activities of the trunk muscles during crutch walking to determine which of the crutch length measurements is most beneficial. METHODS: Twenty young women volunteered to participate in this study. After adjusting crutch length, the participants performed a three-point walking with nondominant leg limited in weight bearing. This study used six crutch length measurements: (1) Height-40.6cm, (2) Height'.77, (3) Olecranon-to-finger length, (4) Axillary-toheel length, (5) Arm-span length-40.6cm, and (6) Arm-span length'.77. The EMG activities of the internal oblique (IO), rectus abdominis (RA), multifidus (MF), and erector spinae (ES), muscles on the weight bearing side were monitored using wireless surface EMG. RESULTS: The EMG activities of the RA and ES appeared to be significantly different among the crutch length measurements (p<.05). The post-hoc test showed that the 'Arm-span length-40.6cm' was significantly greater in the RA activity when compared to the 'Height'.77' and 'Axillary-to-heel length' measurements, and in the ES activity when compared to 'Height'.77' measurements. Furthermore, IO/RA and MF/ES ratios showed significant differences among the crutch length measurements (p<.05). In the post-hoc test, significant difference was observed between 'Olecranon-to-finger length' and 'Arm-span length-40.6cm' for the IO/RA ratio, and between 'Height'.77' and 'Olecranon-to-finger length' and between 'Height'.77' and 'Arm-span length-40.6cm' measurement for the MF/ES ratio. CONCLUSION: These findings suggest that the 'Height'.77' measurement is relatively advantageous to optimize the activities of trunk muscles during the crutch walking, and allow simple measurements of the crutch length.

물리치료사의 손가락 길이 비율에 따른 직무만족도에 관한 연구 -정형도수물리치료분야 중심으로- (A Study of Job Satisfaction by Finger Length Ratio of Physical Therapists : Focused on Orthopedic Manual Therapy Field)

  • 박지환;김호봉;한슬기
    • 대한정형도수물리치료학회지
    • /
    • 제20권2호
    • /
    • pp.21-26
    • /
    • 2014
  • Background: In the present study, we examined gender roles, job satisfaction, and the relationship between the two among orthopedic manual physical therapists (OMT). Methods: The subject of this study was 208 physical therapists working in the general hospital and rehabilitation in Daejeon. In order to examine the nature of the subject, we calculated the ratio of second finger length for fourth finger of predominant hand and completed the questionnaire to determine the general characteristics and job satisfaction. Results: The OMT and NOMT (non OMT) digit ratio results were not significantly different (p>.05). Digit ratio based on gender was also not significantly different between groups (p>.05). Among the job satisfaction survey items, OMT was significantly higher than NOMT in terms of Pride, Reflection of opinions, aptitude match, and field satisfaction (p<.05); however, there were no significant differences between groups for the remaining items. Digit ratio was not significantly related to any of the job satisfaction items (p>.05). Conclusions: We determined that gender roles had a limited influence on selecting and continuing with orthopedic physical therapy.

수지 첨부 절단의 재접합술 (Finger Tip Replantation)

  • 공병선;김용진
    • Archives of Reconstructive Microsurgery
    • /
    • 제12권2호
    • /
    • pp.105-111
    • /
    • 2003
  • It has been known that the vessels of the finger tip are very small and have many branches, so the anastomosis of this vessel is very difficult. But when this operation achieves success, the replanted finger tip provides adequate soft tissue, restoration of the length, sensory and nail. The authors describe the result of finger tip replantation in 94 patients, 103 finger tips, from October 1999 to June 2002. We performed the salvage procedure in all cases. The success rate of finger tip replantation was 74.8%. We achieved higher success rate, when we succeeded anastomosis of the central artery. The function of the replanted fingers was good. The average TAM was 80% and patient satisfaction was high. We be live that we can achieve higher success rate by anastomosing central artery and performing delicate salvage procedure.

  • PDF

골프장갑의 착용실태 조사 및 기능성 향상을 위한 디자인 제안 (A Study on the Wearing Conditions of Golf Gloves and a Proposal for a Functional Glove Design)

  • 류현숙;최혜선;김은경
    • 대한가정학회지
    • /
    • 제42권6호
    • /
    • pp.89-101
    • /
    • 2004
  • The aim of this study is to investigate problems with both fit and abrasion of golf gloves through a survey of golf usage among golfers over the age of 30, as well as by analyzing the golf glove industry with an emphasis on the size system and marketing situation. In addition, this study aims to suggest the basic raw materials for improving the design of golf gloves through physical properties inspections. The results of the analyses support the following suggestions. First of all, dissatisfaction arose from improper measurement in glove length. The survey showed that most problems occur in the pinky finger, while only the length of the middle finger of the glove is recorded based on Korean Standard Anthropometries Measurement. Clearly, proper measurements of every finger need to be included in the system. Secondly, the survey results clearly indicated regions 7(palm area) and 3(second finger area) as the areas requiring reinforcement. While the method of patching another layer with the same material is commonly used in the current glove market, materials other than genuine leather are unable to complement the abrasion. This study suggests that another layer of refill type genuine leather, which scored best in the physical properties inspection, needs to be patched onto regions 7 and 3.

동맥화 정맥 유리 피판술을 이용한 수부와 수지 연부조직 결손의 재건 (Soft Tissue Reconstruction of Finger and Hand Using Arterialized Venous Free Flap)

  • 공병선;김용진;조광우
    • Archives of Reconstructive Microsurgery
    • /
    • 제13권2호
    • /
    • pp.107-116
    • /
    • 2004
  • Flaps are necessary, when important structures such as bone, tendon, nerve and vessel are exposed. Arterialized venous free flap is suited to the coverage of finger and hand because the thickness of venous flap is thin. Authors performed 65 cases arterialized venous free flap for the soft tissue reconstruction of the hand and finger. The size of donor defect were from $1{\times}1cm\;to\;7{\times}12cm$. The mean flap area was $9.1cm^2$. The recipient sites were finger tip in 34 cases, finger shaft in 29 cases and hand in 2 cases. The donor sites were volar aspect of distal forearm in 40 cases, thenar area in 17 cases and foot dorsum in 6 cases. The types of arterialized venous free flap were A-A type in 4 cases and A-V type in 61 cases. The length of afferent vein was from 0.5 cm to 3 cm (mean 1.7 cm) and efferent vein was from 1 cm to 10 cm (mean 2.2 cm). 58 flaps(89.2%) survived eventually. 42 flaps(64.6%) survived totally without any complication. 8 flaps(12.3%) showed the partial necrosis but they were healed without any additional operations. 8 flaps (12.3%) showed the partial necrosis requiring the additional skin graft. We had a satisfactory result by using arterialized venous free flap for the soft tissue reconstruction of finger and hand. We believe that volar aspect of distal forearm, thenar area, foot dorsum are suited as a donor site and the short length of the flap pedicle, the strong arterail inflow affect the survival rate of arterialized venous free flaps.

  • PDF

손가락 비율을 이용한 장애인 특성 (Analysis on characteristics of person with disability using ratio of the lengths of the second to fourth digits)

  • 김성진;신현욱;이병순;최지원;최경호
    • Journal of the Korean Data and Information Science Society
    • /
    • 제23권6호
    • /
    • pp.1145-1154
    • /
    • 2012
  • 태아기의 성 호르몬의 차이가 두 번째 손가락과 네 번째 손가락 길이의 비율을 비롯하여 여러가지 생리적 특성에 영향을 미칠 수 있다는 연구가 발표된 이후 관련 연구가 많이 진행되어 오고 있다. 그러나 우리나라 장애인을 대상으로 한 연구는 드물다. 이에 본 연구에서는 우리나라 장애인과 일반학생을 대상으로 손가락 비율 비교 및 장애인의 특성을 실증적으로 분석해 보았다. 그 결과, 장애인과 일반학생 모두에 있어 남자의 손가락 검지와 약지 길이 비율이 여자보다 낮아, 남녀별 성차가 있다는 일반적 사실을 확인 할 수 있었다. 다음으로, 남자와 여자 장애인 모두에서 나이대별 손가락 길이 비율은 통계적으로 유의한 차이가 없는 것으로 나타나, 일반인과 마찬가지로 장애인도 성장과정에서 검지와 약지 길이 비율이 크게 변하지 않음을 알 수 있었다. 마지막으로, 남자와 여자 지적 장애인 모두에 대하여 장애등급별 손가락 길이 비율도 통계적으로 유의하지 않은 것으로 나타난 바, 이로부터 손가락 검지와 약지 길이 비율이 장애여부와 관계가 있다는 점에 근거하면 현재의 장애등급 구분은 문제가 있다고 하겠다.

Relationship between Gender Roles and Job Satisfaction among Neurological Physical Therapists

  • Park, Ji-Whan;Han, Seul-Ki;Lee, Dae-Hee
    • 대한물리의학회지
    • /
    • 제11권3호
    • /
    • pp.81-88
    • /
    • 2016
  • PURPOSE: This study was aimed at investigating the types of gender roles and the relationship between gender roles and job satisfaction among neurological physical therapists. METHODS: The study subjects were 169 (male 74, female 95) neurological physical therapists working at general hospitals or rehabilitation centers in the Daejeon Metropolitan City area, South Korea. To identify job satisfaction scores, the subjects completed a questionnaire, and a vernier caliper was used by a trained examiner to measure the lengths of the subjects' index and ring fingers (i.e., digitus secundus manus and digitus annularis, respectively) to examine gender roles. The index to ring finger length ratio (i.e., 2D:4D ratio) was calculated using a personal computer. An independent t-test was performed to compare the finger length ratio and job satisfaction of male group with that of the female group and a correlation analysis was performed to examine job satisfaction by gender roles. RESULTS: Finger length ratio is lower in males than in females. However, there was no significant difference statistically (p>.05). Regarding job satisfaction by gender, males were more satisfied with their jobs than females (p<.05). However, there were no significant correlations between job satisfaction and gender roles (p>.05). CONCLUSION: It cannot be concluded that bias against gender roles is a contributing factor for neurological physical therapists being satisfied with their job, and thus bias against gender roles among neurological physical therapists should be removed.

Molecular characterization of BrRZFPs genes encoding C3HC4 type RING zinc finger protein under abiotic stress from Chinese cabbage (Brassica rapa L.)

  • Jung, Yu Jin;Lee, Kye Dong;Cho, Yong Gu;Nou, Ill Sup;Kang, Kwon Kyoo
    • Journal of Plant Biotechnology
    • /
    • 제40권2호
    • /
    • pp.102-110
    • /
    • 2013
  • The novel BrRZFPs genes encoding C3HC4-type RING zinc finger protein were identified from FOX (full length cDNA over-expressing) library of Brassica rapa. Ten full-length cDNAs obtained from the library encode zinc-finger protein containing 346 amino acids, designated BrRZFPs. These genes were classified into four groups by phylogenic analysis showing conserved protein sequences at both termini. The tissue distribution of BrRZFPs transcription was examined by qRT-PCR revealing ubiquitous expression pattern. However, each gene was strongly expressed in the specific tissue. Transcriptional analysis showed that those acquired 10 genes were inducible under abiotic stresses. Likewise, the transcript of BrRZFP3 was strongly induced (~12-folds) by exogenous abscisic acid, whereas the transcripts of BrRZFP1, BrRZFP2 and BrRZFP3 were (> 9-folds) induced by cold. We suggest that these BrRZFPs that function as signal or response to abiotic stress are useful for crop improvement.

작업용 장갑 개발을 위한 성인 남성 손 형태 분석 (Analyzing Adult Male Hand Shape for the Development of Work Gloves)

  • 차수정
    • 패션비즈니스
    • /
    • 제27권4호
    • /
    • pp.21-37
    • /
    • 2023
  • This study aimed to classify the hand types of adult males aged 20 to 69 years using three-dimensional measurement data from the 2020 8th Korean Anthropometric Survey, the latest measurement data from the National Institute of Standards and Technology Size Korea, and explore the characteristics of each type. Through this, I aimed to draw implications for the development of work gloves. The factors that make up an adult male's hand were categorized into hand and finger thickness factors, palm length factors, and finger length factors. Adult male hands were categorized into four types: small, thin hands and long fingers; thick, long fingers; medium, short hands and fingers; and large, thin, short fingers. The analysis showed that the younger the age, the more slender and long the hands and fingers, and as age increased, hands and fingers became shorter and thicker. Implications for the development of work gloves included the need for size segmentation based on the age of the work glove user, changes in the way glove dimensions are set based on hand length and hand circumference, and the need to segment gloves by the type of work. Hand typing in future research should be done according to occupational groups, and glove patterns should be developed for each type of work based on the results of this study.

전기활성 고분자 구동체에 의한 손가락 모형의 집기 운동 분석 (Analysis of Pinching Motion of a Finger Dummy Actuated by Electro-active Polymer Actuators)

  • 이두원;민민식;이수진;조재영;김동민;이계한
    • 한국정밀공학회지
    • /
    • 제31권7호
    • /
    • pp.643-649
    • /
    • 2014
  • In order to demonstrate the possibility of applying an ionic polymer metal composite (IPMC) to a finger exoskeleton, pinching motion analysis was performed for a thumb-index finger dummy actuated by IPMC actuators. The IPMC actuators of 5mm in width and 40mm in length with 2.4mm thickness generated 1.52N of blocking force for the applying voltage of 4.0V. Three actuators were installed on the three rotary joint of an index finger, and one actuator was installed on one proximal joint. Positions of each joint and finger tip were recorded on the video camera, and motion was analyzed. Power supply to the index finger actuators preceded power supply to the thumb actuator, and key pinching motion was accomplished in 180s. Tip pinching was accomplished in 135s as power supply to the thumb preceded power supply to the index finger.