• 제목/요약/키워드: Fin Spacing

검색결과 34건 처리시간 0.022초

낮은핀관의 액막 증발 촉진에 관한 연구 (Enhancement of thin film evaporation on low-fin tubes)

  • 김내현
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.674-682
    • /
    • 1998
  • In this study, thin film evaporation of water on low-fin tubes were experimentally investigated. Five low-fin tubes with different fin spacing and fin height were tested. Test range covered 0.146kg/ms $\leq$$\Gamma$$\leq$0.219kg/ms and 10㎾/$\m^2$$\leq$q $\leq$70㎾/$\m^2$. Saturation temperature was loot. Compared with the plain tube, low fin tubes enhanced the water film evaporation from 60% to 100%. Tubes with fin spacing smaller than 2mm and fin height higher than 1mm performed better than tubes with other fin configuration. However, when fin spacing was too small at high film flow or fin height was too high at low film flow, the performance decreased. The heat transfer coefficient slightly increased as the flow rate increased. Correlations are developed based on present data.

  • PDF

착상시 설계인자에 따른 핀-관 열교환기의 성능변화에 관한 실험적 연구 (An Experimental Study on the Effects of Design Factors for the Performance of Fin-Tube Heat Exchanger Under Frosting Conditions)

  • 이관수
    • 대한기계학회논문집
    • /
    • 제19권10호
    • /
    • pp.2657-2666
    • /
    • 1995
  • In this study, the effects of design factors of finned-tube heat exchanger, such as fin spacing and fin array on the frost growth and heat exchanger performance are investigated under a frosting condition. The results show that the amount of frost, frost density and blockage ratio of air flow passage increase with decreasing fin spacing. Heat transfer rate increases momentarily at the initial stage of frosting and then decreases. After that heat transfer rate continues to increase again to reach a maximum value and then decreases dramatically. It is shown that the time required for heat transfer rate to reach a maximum value becomes shorter with decreasing fin spacing, and after a maximum value, heat transfer rate decreases very fast. The maximum allowable blockage ratio is introduced to determine the operation limit of a finned-tube heat exchanger operating under frosting condition and is obtained as a function of fin spacing. It is also shown that heat transfer rate of heat exchanger with staggered fin array increases about 17% and the amount of pressure drop of air increases about 1~2 mmH$_{2}$O, compared with those of in-line type heat exchanger under frosting condition.

휜이 달린 수소저항합금 베드의 수소저장 성능의 수치적 예측 (Numerical prediction of hydrogen storaging performance of finned metal hybride beds)

  • 김명찬;이상용;구재학
    • 대한기계학회논문집B
    • /
    • 제22권4호
    • /
    • pp.520-529
    • /
    • 1998
  • Heat and mass transfer behaviors of metal hydride beds were predicted by solving a set of volume-averaged equations numerically both for the gas (hydrogen) and the solid(metal hydride) phases. Time variations of temperature and hydrogen concentration ratio distributions were obtained for internally cooled, cylindrical-shaped beds with metal(aluminum) fins imbedded in them. Also, time variations of the space-averaged hydrogen concentration ratio were obtained. Temperature and velocity of the coolant, hydrogen pressure at the gas inlet, and the fin spacing were taken as the parameters. The hydrogen absorption rate increases with the higher velocity and the lower temperature of the coolant, and with the decrease of the fin spacing. Increasing of the hydrogen pressure at the gas inlet also promotes the rate of absorption though the increasing rate gradually slows down. The amount of the hydrogen storage per unit volume of the bed decreases with the tighter fin spacing despite of the higher absorption rate ; therefore, there should be an optimum fin spacing for a given volume of the system and the amount of the hydrogen storage, in which the absorption rate is the highest.

단일 핀-관 열교환기에서 엔트로피 생성에 관한 연구 (A Study on the Entropy Generation of Single Fin-Tube Heat Exchanger)

  • 박희용;이관수;김병규
    • 태양에너지
    • /
    • 제10권1호
    • /
    • pp.14-21
    • /
    • 1990
  • 단일 핀-관열교환기와 관련된 열역학적 최적설계법을 기준하여 핀-관열교환기의 엔트로피 생성율을 조사하였다. 엔트로피 생성율(비가역성)해석법을 사용하여 최적설계조건을 구하였고 설계조건의 변화에 따른 총엔트로피 생성율과 핀의 길이, 관의 안지름과 바깥지름 및 핀간거리를 조사하였다. 이 연구의 결과에 따르면 바깥지름이 클수록 최적핀간거리와 핀높이는 커지고 엔트로피 생성율과 최적안지름은 작아진다. 또한 핀 두께를 증가시키면 계의 엔트로피 생성율과 최적핀간거리는 증가하고 핀높이를 증가시키면 엔트로피 생성율과 최적바깥지름은 증가한다.

  • PDF

스트립휜 히트싱크의 냉각특성 (Cooling Characteristics of a Strip Fin Heat Sink)

  • 박철우;김현우;장충선;유갑종
    • 대한기계학회논문집B
    • /
    • 제29권1호
    • /
    • pp.16-26
    • /
    • 2005
  • Air-cooled heat sinks are employed in many electronic cooling applications since they provide significant heat transfer enhancement and operational flexibility. Strip-shaped fin heat sink is of interest and needs to be investigated as general cooling products for more applicability. The purposes of this study are to evaluate heat sink performance without bypass flow condition and to determine optimal heat sink geometries. The results show that the decreasing rate of thermal resistance of a heat sink decreases with increasing inlet air velocity, and the increasing rate of pressure drop increases with increasing inlet air velocity, but is not affected by input power. The increasing rate of optimal longitudinal fin spacing is larger than that of transverse fin spacing. The strip fin heat sink tested in this study showed better cooling performance compared to that of other plate fin type.matism. 2004; 50(11): 3504-3515.

환상핀이 부착된 원봉에서 핀 간격에 따른 대류열전달 해석 (EFFECTS OF FIN SPACING ON CONVECTIVE HEAT TRANSFER FOR A CIRCULAR CYLINDER WITH ANNULAR FINS)

  • 박태선;김창하
    • 한국전산유체공학회지
    • /
    • 제19권2호
    • /
    • pp.1-7
    • /
    • 2014
  • This study is to analyze the local convective heat transfer for a circular cylinder with annular fins. The relation between wall heat transfer and three-dimensional flow is investigated for different distances of annular fins. Depending on the fin spacing, the flow structure is strongly changed by the variation of horseshoe vortices. As the fin spacing increases, the heat transfer rate is maximized at a certain condition. This is clearly obtained as the Reynolds number increases, and it is closely related to the development of horseshoe vortices.

나선형 핀튜브 열교환기의 열전달 특성에 관한 실험적 연구 (Experimental Study on the Heat Transfer Characteristics of Spiral Fin-Tube Heat Exchangers)

  • 윤린;김용찬;김슬우;최종민
    • 설비공학논문집
    • /
    • 제17권6호
    • /
    • pp.529-535
    • /
    • 2005
  • This study experimentally examines the air-side performance of spiral finned tube heat exchangers. The effects of fin spacing, fin height, and tube alignment were investigated. Reduction of fin spacing decreased the Colburn j factor. However, the effect of fin height on the Colburn j factor was negligible. An increase of tube row decreased the Nusselt number for both staggered and in-line tube alignments. However, the decrease of the Nusselt number for the in-line tube alignment was much more significant than that of the staggered tube alignment. The average Nusselt number of the staggered tube alignment was larger than that of the in-line tube alignment by $10\%$ when the Reynolds number ranged from 300 to 1700. An empirical correlation of the Nusselt number was developed by using geometric parameters of heat exchanger and correction factors. The correction factor considered the effects of tube alignment and number of tube rows on the heat transfer. The proposed correlation yielded a mean deviation of $4\%$ from the present data.

An Experimental Study on Air-side Performance of Fin-and-Tube Heat Exchangers with Slit Fin

  • Chang, Keun-Sun;Phan, Thanh-Long
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.627-632
    • /
    • 2006
  • An experimental study is conducted to investigate the effect of the tube row and fin spacing on the air-side heat transfer and friction characteristics of fin-tube heat exchangers with slit fin pattern. A total of twelve samples of fin-tube heat exchangers with the nominal tube diameter of 7 mm, transverse tube pitch of 19 mm and longitudinal tube pitch of 12.5 mm are tested. The thermal fluid measurements are made using a psychometric calorimeter. The raw data are reduced to the desired heat transfer coefficient in terms of j-factor and friction factor of f for various frontal air velocities, fin pitches and number of tube rows.

  • PDF

핀-휜 배열을 이용한 채널의 냉각특성 실험 (Experiments on the Cooling Characteristics of a Channel with Pin-Fin Array)

  • 김상민;신지영;손영석;이대영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.31-36
    • /
    • 2003
  • Recently, the power consumption and heat generation in an electronic equipment increase as the components are miniaturized and the computing speed becomes faster. Effective cooling method is required to ensure the guaranteed performance and reliable operation of the electronic devices. The aim of the present study is to investigate the cooling characteristics of a pin-fin heat exchanger as a candidate for cooling system of the electronic devices. Various configuration of the pin-fin array is selected in order to find out the effect of spacing and diameter of the pin-fin on the heat transfer characteristics. The results are compared with the experimental data or correlations of several researchers for the channel flow with pin-fin arrays.

  • PDF

습표면 조건에서 슬릿 핀-튜브 열교환기의 열전달 및 압력강하 특성 (Heat Transfer and Friction Characteristics of Slit Fin and Tube Heat Exchangers in Wet Conditions)

  • 장근선
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.1-9
    • /
    • 2007
  • Water condensate accumulated on the surface of a fin-and-tube heat exchanger significantly affects its thermal and hydraulic performance. The purpose of this study is to investigate the effect of condensate retention on the air-side heat transfer performance and flow friction. Total 12 samples of slit and plate fin-and-tube heat exchangers with varying fin spacing and number of tube rows are tested under dry and wet conditions. The thermal fluid measurements are made using a psychometric calorimeter. Frontal air velocity varies in the range from 0.7 m/s to 1.5 m/s. Using the experimental data, presented are the heat transfer coefficients in terms of Colburn j-factor and friction factor.