Abstract
This study is to analyze the local convective heat transfer for a circular cylinder with annular fins. The relation between wall heat transfer and three-dimensional flow is investigated for different distances of annular fins. Depending on the fin spacing, the flow structure is strongly changed by the variation of horseshoe vortices. As the fin spacing increases, the heat transfer rate is maximized at a certain condition. This is clearly obtained as the Reynolds number increases, and it is closely related to the development of horseshoe vortices.
Keywords
Circular Cylinder; Laminar Flow; Horseshoe Vortex; Annular Fins; Convective Heat Transfer;
Citations & Related Records
연도 인용수 순위
  • Reference
1 2011, Giordano, R., Ianiro, A., Astarita, T. and Carlomagno, G. M., "Flow field and heat transfer on the base surface of a finite circular cylinder in crossflow," Applied Thermal Engineering, Vol.49, pp.1-10.
2 1993, Sung, H.J., Yang, J.S., and Park, T.S., "Local convective mass transfer on circular cylinder with transverse annular fins in crossflow," Int. J. Heat and Mass Transfer, Vol.39, pp.1093-1101.
3 2000, Romero-Mendez, R., Sen, M., Yang, K.T., McClain, R., "Effect of fin spacing on convection in a plate fin and tube heat exchanger," Int. J. Heat and Mass Transfer, Vol.43, pp.39-51.   DOI   ScienceOn
4 2006, Sanhaji M., Bougeard D., Abbadi A. E., Russeil S., Nacer-Bey M. and Baudoin B., "Infrared thermography study of the local heat transfer coefficient in front of a single finned tube", 8th Int. Conference on Quantitative InfraRed Thermography, Italy, N12.
5 1999, Sheui, W.H., Tsai, S.F. and Chiang, T.P., "Numerical study of heat transfer in two-row heat exchangers having extended fin surfaces," Numerical Heat Transfer, Part A, Vol.35, pp.797-814.   DOI   ScienceOn
6 2004, Mon, M.S. and Gross, U., "Numerical study of fin-spacing effects in annular-finned tube heat exchangers," Int. J. Heat and Mass Transfer, Vol.47, pp.1953-1964.   DOI   ScienceOn
7 2006, Park, T.S., "Effects of time-integration method in a large-eddy simulation using the PISO algorithm: Part I-Flow field," Numerical Heat Transfer, Part A, Vol.50, pp.229-245.   DOI   ScienceOn
8 1992, Lele, S.K., "Compact finite difference schemes with spectral-like resolution," J. Computational Physics, Vol.103, pp.16-42.   DOI   ScienceOn
9 1968, Dennis, S.C.R., Hudson, J.D., and Smith, N., "Steady laminar forced convection from a circular cylinder at low Reynolds numbers," Physics of Fluids, Vol.11, pp.933-939.   DOI
10 1998, Williamson, C.H.K. and Brown, G.L., "A series in 1/$\sqrt{Re}$ to present the Strouhal-Reynolds number relationship of the cylinder wake," Journal of Fluids and Structures, Vol.11, pp.1073-1085.