• Title/Summary/Keyword: Filter efficiency

Search Result 1,510, Processing Time 0.034 seconds

Fine Particle Removal by a Vehicle Air Cleaner (차량용 에어클리너의 미세입자 제거특성)

  • Park, Byung-Hyun;Kim, Sang-Bum;Kim, Gyung-Soo;Lee, Sang-Ryul;Lee, Myong-Hwa
    • Journal of ILASS-Korea
    • /
    • v.12 no.2
    • /
    • pp.86-93
    • /
    • 2007
  • There is a growing interest to develop an eco-friendly air cleaner with high performance through a remanufacturing process. Two kinds of polyurethane filter media, a coarse (Filter-A) and a fine filter media (Filer-B), are used in this study to protect a vehicle engine from airborne particles. In order to improve the collection performance of the filters (Filter-A, Filter-B), an oil coating technology on the filter surface was introduced. As a result, inertial force is a dominant collection mechanism for a dry filter media, so that collection efficiency increases with increasing filtration velocity. However, intra-structure change of an oil-coated filter media influences on the collection mechanism, which shows a non-linear collection efficiency curve in terms of filtration velocity. The result shows that the developed filter media are eco-friendly and effective to protect a vehicle engine from airborne particles especially at low filtration velocity.

  • PDF

Korean Alphabet Recognition using Phase-only Filter (위상필터를 이용한 한글문자 인식)

  • Lee, Jae-Cheol;Doh, Yang-Hoi;Ha, Yeong-Ho;Kim, Soo-Joong
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1445-1448
    • /
    • 1987
  • The phase-only filter (POF) to the classical matched filter is compared for the criteria of discrimination, correlation peak, and optical efficiency in Korean alphabet. In addition, logarithmically scaled POF is presented to improve the recognition efficiency and this shows the superior performances in English alpanumeric characters to Korean.

  • PDF

New Video Compression Method based on Low-complexity Interpolation Filter-bank (저 복잡도 보간 필터 뱅크 기반의 새로운 비디오 압축 방법)

  • Nam, Jung-Hak;Jo, Hyun-Ho;Sim, Dong-Gyu;Choi, Byeong-Doo;Cho, Dae-Sung
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.5
    • /
    • pp.165-174
    • /
    • 2010
  • The H.264/AVC standard obtained better performance than previous compression standards, but it also increased the computational complexity of CODEC simultaneously. Various techniques recently included at the KTA software developed by VCEG also were increasing its complexity. Especially adaptive interpolation filter has more complexity than two times due to development for coding efficiency. In this paper, we propose low-complexity filter bank to improve speed up of decoding and coding gain. We consists of filter bank of a fixed-simple filter for low-complexity and adaptive interpolation filter for high coding efficiency. Then we compensated using optimal filter at each macroblock-level or frame-level. Experimental results shows a similar coding efficiency compared to existing adaptive interpolation filter and decoding speed of approximately 12% of the entire decoder gained.

Study on improvement of efficiency of gas filter at the natural gas valve station (천연가스 공급기지내 가스필터 성능개선에 관한 연구)

  • Cho Y.B.;Jeon K.S.;Her J.Y.;You K.H.
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.1
    • /
    • pp.47-52
    • /
    • 1998
  • To eliminate foreign substance like metal rust and sand in natural gas pipeline, 250um strainer filter is used present in Korea Gas Corporation. But particles smaller than 250um passing the filter have bad effects to the valves and the measuring equipments. In order to eliminate small paticle in the pipeline, it is necessary to cut down the pore size of filter When we cut down the pore size of filter, the pressure difference between the front of filter and that of the rear part is increasing and disturb normal condition of gas supply. So it is very important to control the condition between the pore size of filter and the pressure difference. In this study, using head loss coefficient K, the estimation method of efficiency of gas filter according to the pore size and the pressure difference is presented.

  • PDF

Phosphorus Removal in Pilot Plant Using Biofilm Filter Process from Farm Wastewater

  • Shin, Sung-Euy;Choi, Du-Bok;Lee, Choon-Boem;Cha, Wol-Suk
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.4
    • /
    • pp.325-331
    • /
    • 2006
  • Various environmental conditions affecting total phosphorus removal from farm wastewater in a biofilm filter process were investigated using loess balls and Chromobacterium LEE-38 at a pilot plant. When Chromobacterium LEE-38 was used, the removal efficiency of total phosphorous was approximately 10- or 5-fold higher than that of Acinetobacter CHA-2-14 or Acinetobacter CHA-4-5, respectively. When a loess ball of $11{\sim}14mm$ manufactured at a $960^{\circ}C$ calcining temperature was used, the removal efficiency of total phosphorous was 90.0%. When 70% of the volume fraction was used, the maximum efficiency of total phosphorus removal was 93.1%. Notably, when the initial pH was in the range of 6.0 to 8.0, the maximum removal efficiency of total phosphorus was obtained after 30 days. When the operating temperature was in the range of 30 to $55^{\circ}C$, the maximum removal efficiencies of total phosphorus, 95.6 to 94.6%, were obtained. On the other hand, at operating temperatures below $20^{\circ}C$ or above $40^{\circ}C$, the removal efficiency of total phosphorous decreased. Among the various processes, biofilm filter process A gave the highest removal efficiency of 96.4%. Pilot tests of total phosphorus removal using farm wastewater from the biofilm filter process A were carried out for 60 days under optimal conditions. When Acinetobacter sp. Lee-11 was used, the average removal efficiency in the p-adsorption area was only 32.5%, and the removal efficiencies of chemical oxygen demand (COD) and biological oxygen demand (BOD) were 56.7 and 62.5%, respectively. On the other hand, when Chromobacterium LEE-38 was used, the average removal efficiency was 95.1%, and the removal efficiencies of COD and BOD were 91.3 and 93.2%, respectively.

Adaptive filter Design for INS/GPS (INS/GPS를 위한 적응필터 구성)

  • Yu Myeong-Jong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.8
    • /
    • pp.717-725
    • /
    • 2005
  • The adaptive filter is proposed for the INS/GPS. The proposed filter can estimate the variance of the process noise using the residual of the filter. To verify the efficiency of the adaptive filter, it is applied to the loosely-coupled INS/CPS that employs the additive quaternion error model. Simulation results demonstrate that the proposed filter is more effective in estimating the attitude error than EKF.

The adsorption efficiency of ceramic filter media prepared with the steel-making slag for the removal of VOCs (휘발성 유기화합물 제거를 위한 제강슬래그로 제조된 세라믹 여재의 흡착효율)

  • Sin, Jun-Ho;Kim, Tae-Heui;Park, Kyung-Bong
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.20 no.3
    • /
    • pp.153-157
    • /
    • 2010
  • We studied the adsorption efficiency of steelmaking slag in removing volatile organic compounds (VOCs) for increasing the recycling rate of steel-making slag. Ceramic filter was prepared by mixing the steel-making slag and the diatomite which is used as adsorbents due to the advantage of the high specific surface area and regular mesopores. The adsorption efficiency for VOCs removal was about 80%, 96% and 85% in acetaldehyde, formaldehyde and ammonia, respectively. The adsorption efficiency over 80% for all The gases showed the practical possibility as the adsorption filter.

Study of Catalytic Ceramic Fiber Filter Elements for Hot Gas Filtration

  • Young Jin Choi;Min Jin Park;Jun Suk Hong;Min Sun Hong;Jae Chun Lee
    • The Korean Journal of Ceramics
    • /
    • v.5 no.3
    • /
    • pp.284-287
    • /
    • 1999
  • CuO catalyst-coated alumino-silicate fiber filters were prepared for the simultaneous removal of particulate matter and gaseous contaminants such as NOx and SOx. Hot gas cleaning experiments similar to Shell UOP process other than the catalyst supporting materials were carried out between 300 and $500^{\circ}C$ for the evaluation of the gas removal efficiency of the catalytic filter. Experimental results showed that removel efficiency for $SO_2$ was greater than 99% in the temperature range 450~$500^{\circ}C$ and more than 90% of NO was collected between 350 and $370^{\circ}C$. It was found that the higher the CuO content, the higher the removal efficiency for $SO_2$. Removal efficiency for NO was more affected by the gas cleaning temperature than by the CuO content in the catalyst-filter.

  • PDF

Level Number Effect on Performance of a Novel Series Active Power Filter Based on Multilevel Inverter

  • Karaarslan, Korhan;Arifoglu, Birol;Beser, Ersoy;Camur, Sabri
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.711-721
    • /
    • 2018
  • This paper presents a single-phase asymmetric half-bridge cascaded multilevel inverter based series active power filter (SAPF) for harmonic voltage compensation. The effect of level number on performance of the proposed SAPF is examined in terms of total harmonic distortion (THD) and system efficiency. Besides, the relationship between the level number and the number of switching device are compared with the other multilevel inverter topologies used in APF applications. The paper is also aimed to demonstrate the capability of the SAPF for compensating harmonic voltages alone, without using a passive power filter (PPF). To obtain the required output voltage, a new switching algorithm is developed. The proposed SAPF with levels of 7, 15 and 31 is used in both simulation and experimental studies and the harmonic voltages of the load connected to the point of common coupling (PCC) is compensated under two different loading conditions. Furthermore, very high system efficiency values such as 98.74% and 96.84% are measured in the experimental studies and all THD values are brought into compliance with the IEEE-519 Standard. As a result, by increasing the level number of the inverter, lower THD values can be obtained even under high harmonic distortion levels while system efficiency almost remains the same.

Fast Image Retrieval Based on Object Regions Using Bidirectional Round Filter (양방향 반올림 필터를 이용한 객체 영역 기반 고속 영상 검색)

  • 류권열;강경원
    • Journal of Korea Multimedia Society
    • /
    • v.6 no.2
    • /
    • pp.240-246
    • /
    • 2003
  • In this paper, we propose the fast image retrieval method based on object regions using bidirectional round filter in the wavelet transform region. A conventional method that extracts feature vectors on the whole of subband is reduced retrieval efficiency, because of unnecessary background information. The proposed method that extracts feature vectors on the only object region of subband by using bidirectional round filter improve retrieval efficiency, because of removing of background information. And it certainly maintains retrieval efficiency in case of reduction of feature vectors according to color information. Consequently, the retrieval efficiency is improved with 2.5%∼5.3% values, which have a little changes according to characteristics of image.

  • PDF