• 제목/요약/키워드: Filling analysis

검색결과 1,003건 처리시간 0.025초

예방적 유지보수를 위한 소수성 저점도 AP 표면처리재 개발 (The Development of the Hydrophobic - Low Viscosity Filling Material for the Surface Treatment for Pavement Preventive Maintenance)

  • 최준성;김조순
    • 한국도로학회논문집
    • /
    • 제16권2호
    • /
    • pp.35-41
    • /
    • 2014
  • PURPOSES : Surface treatment is a favorable method in the pavement preventive maintenance. This study (Part I) aimed to develop the low viscosity filling material for waterproof characteristics and high penetrable and weather resistance, and a series of companion study (Part II) presents the coating characteristics and performance analysis using field and lab tests. METHODS : Hydrophobic characteristics of the advanced surface treatment material are observed and measured the filling depth and the permeability for sand and asphalt pavement specimen using the water absorption test and permeability test, X-RAY CT test. Color difference for the weather resistance using ultraviolet ray accelerated weathering test is compared with asphalt pavement specimens. RESULTS : The developed material shows the decreased water absorption and increased impermeable effect because of the hydrophobic characteristics. It is found that the filling depth is about 6mm and weather resistance is better than asphalt pavement specimen. CONCLUSIONS : The advanced hydrophobic - low viscosity filling treatment material is developed in this study (Part I) to improve the waterproof characteristics and high filling capacity and weather resistance for the pavement preventive maintenance.

급속 충전에서 탱크 내부의 수소 온도 변화에 관한 이론 연구 (A Theoretical Study on the Hydrogen Temperature Evolution Inside the Tank under Fast Filling Process)

  • 이길초;이길강;허항;최병철;권정태
    • 한국수소및신에너지학회논문집
    • /
    • 제34권6호
    • /
    • pp.608-614
    • /
    • 2023
  • The fast filling process of high-pressure hydrogen has an important impact on the filling efficiency and safety. In this paper, a specific study is carried out on the thermophysical phenomena during the fast filling process. Starting from the gas state equation of hydrogen, the change law of the hydrogen storage temperature is obtained, and then the temperature rise prediction is constructed. The model can clarify the relationship between the filling parameters and the temperature rise during the fast filling process, thereby revealing the flow and heat transfer laws of the fast charging process. To improve the theoretical research basis for the evaluation of vehicle-mounted hydrogen fast charging capacity, temperature prediction and optimization of hydrogenation methods.

The effects of LNG-tank sloshing on the global motions of FLNG system

  • Hu, Zhi-Qiang;Wang, Shu-Ya;Chen, Gang;Chai, Shu-Hong;Jin, Yu-Ting
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제9권1호
    • /
    • pp.114-125
    • /
    • 2017
  • This paper addresses a study of inner-tank sloshing effect on motion responses of a Floating Liquefied Natural Gas (FLNG) system, through experimental analysis and numerical modeling. To investigate hydrodynamic characteristics of FLNG under the conditions of with and without LNG-tank sloshing, a series of numerical simulations were carried out using potential flow solver SESAM. To validate the numerical simulations, model tests on the FLNG system was conducted in both liquid and solid ballast conditions with 75% tank filling level in height. Good correlations were observed between the measured and predicted results, proving the feasibility of the numerical modeling technique. On the verified numerical model, Response Amplitude Operators (RAOs) of the FLNG with 25% and 50% tank filling levels were calculated in six degrees of freedom. The influence of tank sloshing with varying tank filling levels on the RAOs has been presented and analyzed. The results showed that LNG-tank sloshing has a noticeable impact on the roll motion response of the FLNG and a moderate tank filling level is less helpful in reducing the roll motion response.

Quantitative assessment of image artifacts from root filling materials on CBCT scans made using several exposure parameters

  • Rabelo, Katharina Alves;Cavalcanti, Yuri Wanderley;de Oliveira Pinto, Martina Gerlane;Melo, Saulo Leonardo Sousa;Campos, Paulo Sergio Flores;de Andrade Freitas Oliveira, Luciana Soares;de Melo, Daniela Pita
    • Imaging Science in Dentistry
    • /
    • 제47권3호
    • /
    • pp.189-197
    • /
    • 2017
  • Purpose: To quantify artifacts from different root filling materials in cone-beam computed tomography (CBCT) images acquired using different exposure parameters. Materials and Methods: Fifteen single-rooted teeth were scanned using 8 different exposure protocols with 3 different filling materials and once without filling material as a control group. Artifact quantification was performed by a trained observer who made measurements in the central axial slice of all acquired images in a fixed region of interest using ImageJ. Hyperdense artifacts, hypodense artifacts, and the remaining tooth area were identified, and the percentages of hyperdense and hypodense artifacts, remaining tooth area, and tooth area affected by the artifacts were calculated. Artifacts were analyzed qualitatively by 2 observers using the following scores: absence (0), moderate presence (1), and high presence (2) for hypodense halos, hypodense lines, and hyperdense lines. Two-way ANOVA and the post-hoc Tukey test were used for quantitative and qualitative artifact analysis. The Dunnet test was also used for qualitative analysis. The significance level was set at P<.05. Results: There were no significant interactions among the exposure parameters in the quantitative or qualitative analysis. Significant differences were observed among the studied filling materials in all quantitative analyses. In the qualitative analyses, all materials differed from the control group in terms of hypodense and hyperdense lines (P<.05). Fiberglass posts did not differ statistically from the control group in terms of hypodense halos(P>.05). Conclusion: Different exposure parameters did not affect the objective or subjective observations of artifacts in CBCT images; however, the filling materials used in endodontic restorations did affect both types of assessments.

광중합 콤포짓트레진의 수복형태 및 방법에 관한 삼차원 유한요소분석법적 비교 연구 (A COMPARATIVE STUDY ON THE COMPOSITE RESTORATION DESIGN AND PLACEMENT METHODS USING THREE DIMENSIONAL FINITE ELEMENT ANALYSIS)

  • 이정택;임순호;장익태
    • 대한치과보철학회지
    • /
    • 제36권1호
    • /
    • pp.133-149
    • /
    • 1998
  • Clinical application of composite resin recently draw great concerns in dentistry. Especially due to advantages such as esthetics, adhesiveness, simple clinical procedures, various shapes and kinds of composite resins are widely being applied to prosthodontics, conservative dentistry, and orthodontics. But, clinical problems attributable to the polymerization shrinkage of composite resin have been proposed, and we have to regard clinical problems such as secondary caries, loss of restoration, fracture of the surrounding tooth structure, marginal discoloration, and tooth sensitivity, and many portions are remained to be overcome. Therefore, this study attempts to analyze stress distribution between resin and tooth structure which is generated during polymerization shrinkage of composite resin using three dimensional finite element method. Three dimensional finite element models with conventional box-shape cavity and erosion/abrasion type V-shape lesion cavity in upper central incisor were developed. These cavities were filled with four different types of placement techniques. (bulk filling, horizontal increment filling, oblique occlusal increment filling, oblique gingival increment filling) The stresses generated by polymerization shrinkage of composite resin were calculated. The results analyzed with three dimensional finite element method were as follows : 1. The increment filling technique showed the highest maximum normal stress in both conventional box-shape and V-shape cavities and showed a tendency to decrease after complete polymerization. 2. The bulk filling technique resulted in increased stresses during the curing process in both conventional box-shape and V-shape cavities and the highest maximum normal stress occurred after complete polymerization. 3. The bulk filling resulted in the lowest maximum normal stress in both box-shape and V-shape cavities 4. Regardless of placement method, in conventional box-shape cavity, the maximum normal stress increased in dentin floor, enamel, dentin sequence and in V-shape cavity, the maximum normal stress increased in enamel, dentin sequence.

  • PDF

Efficacy of reciprocating instruments and final irrigant activation protocols on retreatment of mesiobuccal roots of maxillary molars: a micro-CT analysis

  • Lilian Tietz;Renan Diego Furlan;Ricardo Abreu da Rosa;Marco Antonio Hungaro Duarte;Murilo Priori Alcalde;Rodrigo Ricci Vivan;Theodoro Weissheimer;Marcus Vinicius Reis So
    • Restorative Dentistry and Endodontics
    • /
    • 제47권1호
    • /
    • pp.13.1-13.13
    • /
    • 2022
  • Objectives: This study evaluated the efficacy of 3 reciprocating systems and the effects of 2 instruments for irrigant activation on filling material removal. Materials and Methods: Forty mesiobuccal roots of maxillary molars were prepared up to size 25.06 and obturated. Micro-computed tomography (micro-CT) examination #1 was performed. Teeth were then divided into 4 groups (n = 10), according to the retreatment protocol: (1) manual, (2) Reciproc Blue, (3) WaveOne Gold, and (4) X1 Blue. Micro-CT examinations #2 and #3 were performed after filling removal and repreparation, respectively. Next, all teeth were divided into 2 new groups (n = 20) according to the irrigant activation protocol: XP Clean (XP Clean size 25.02) and Flatsonic (Flatsonic ultrasonic tip). Micro-CT examination #4 was performed after irrigant activation. Statistical analysis was performed with a significance level set at 5%. Results: WaveOne Gold removed a significantly greater amount of filling material than the manual group (p < 0.05). The time to reach the WL was similar for all reciprocating systems (p > 0.05). X1 Blue was faster than the manual group (p < 0.05). Only manual group improved the filling material removal after the repreparation stage (p < 0.05). Both activation protocols significantly improved the filling material removal (p < 0.05), without differences between them (p > 0.05). Conclusions: None of the tested instruments completely removed the filling material. X1 Blue size 25.06 reached the working length in the shortest time. XP Clean and Flatsonic improved the filling material removal.

사출성형에 대한 충전과 보압과정의 영향에 관한 연구 (A Study on the Effects of Filling and Packing Phases on the Injection Modeling)

  • 김현필;김용조
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 춘계학술대회 논문집
    • /
    • pp.112-118
    • /
    • 2002
  • Injection molding process factors such as molding temperature, injection pressure, flow rate and flow velocity, must be controlled properly in filling and packing phases in the injection molding process. In this study, effects of these factors on the injection molding were investigated through the flow analysis fur the filling and packing phases. Molding troubles like flow mark, weld line, sink mark, short shot and warpage can be caused by these injection molding process factors. Among them, the short shot was caused by that the packing pressure could not reach properly to the filling end part in the packing phase and hence the flow rate could not be supplied to the full. In addition, as the flow rate for the volumetric shrinkage during the frozen phase could not be supplied properly by the packing pressure, the short shot appeared. Here, the volumetric shrinkage reduced with increasing the packing pressure and also the warpage of molded part increased with increasing the packing pressure.

  • PDF

사출성형의 3차원 충전공정 해석 (Analysis of Three Dimensional Mold-Filling Process in Injection Molding)

  • 최권일;구본흥;차백순;박형필;이병옥
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 추계학술대회 논문집
    • /
    • pp.269-272
    • /
    • 2005
  • For the three decades, the mold-filling of injection molding process was modeled as Hele-Shaw model. However, this model can not consider the 3D effect. In this paper, numerical simulations of three dimensional mold-filling during the filling phase were performed. The governing equations were discretized by segregated finite element method, which used equal order interpolation for pressure and velocity fields. The iterative linear equation solver (JCG, SOR) was employed for the solution of the momentum and pressure equations. Volume of Fluid (VOF) was employed for the melt front advancement. To check the validity of the numerical results, the results were compared with the experimental ones. The agreements between the experiment and the numerical results were found to be satisfactory.

  • PDF

화학제조공정의 무인화를 위한 자동 캡 개폐장치 개발 (Development of an Automatic Cap Opening And Closing Device for Unmanned Chemical Manufacturing Processes)

  • 이준식;권오성;이준호
    • 한국산업융합학회 논문집
    • /
    • 제27권1호
    • /
    • pp.71-76
    • /
    • 2024
  • Automatic production systems are constantly advancing technologies to improve productivity and safety. Specifically, liquid filling machines are primarily utilized to package products into drums after manufacturing process in the hazardous chemical industry. Most existing filling machines allow the operator to open the drum cap and inject the product directly or semi-automation. In this study, we have developed a cap opening and closing mechanism onto the existing drum filling machine, enabling automatic and safe cap manipulation while filling the product in the IBC tank. By applying the appropriate torque value through numerical analysis, we confirmed that the system worked without any problems during the process of opening and closing the cap. Therefore, it is expected that the developed machine will give more production and reduce human efforts without risk in the chemical packaging industry.

사출성형해석 연구를 이용한 게이트 밸런스 계산식의 검증 (Verification of gate balancing equation using injection molding analysis)

  • 한성렬
    • Design & Manufacturing
    • /
    • 제12권3호
    • /
    • pp.55-59
    • /
    • 2018
  • In a multi-cavity mold having a runner layout of a fish bone structure, problems of unbalanced filling between cavities occur constantly. Unbalanced charging lowers the dimensional accuracy of a molded article and causes deformation after molding. To solve this problem, the gate size connected to each cavity is adjusted using the BGV (Balanced Gate Value) equation. In this paper, in order to solve the filling imbalance problem of the runner layout mold of fish bone structure through injection molding analysis study, we compared the charging imbalance phenomenon before and after improvement after adjusting the gate size by applying BGV equation. From the results of the molding analysis, the shrinkage ratio before and after the improvement of the molded article was improved by only about 0.08%. Based on these results, it was confirmed that the charging imbalance problem was not significantly improved even when the BGV equation was applied.