• Title/Summary/Keyword: Fill load

Search Result 100, Processing Time 0.021 seconds

A Study on the Behaviour of an Earth and Rockfill Dam Due to Reservoir Water (저수변화에 따른 사력댐의 거동 연구)

  • Shin, Jong-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.61-70
    • /
    • 2003
  • The behaviour of an earth and rock-fill dam is complicated due to reservoir water and various materials in zoned dams. Different materials with a wide range of permeability and seasonal variation of reservoir water result in the time dependent post-constructional behaviour. In aged dams it is often required to control water level to keep the dams safe. In this case information on the post-constructional dam behaviour is important. However, present geotechnical knowledge does not fully support the occasion. In this study the post-constructional behaviour of a dam is investigated using coupled finite element models for series of idealized water reservoir cases: impoundment, draw down, seasonal fluctuation with different rising and falling speeds. Numerical results were analysed in respect of geotechnical parameters such as load transfer, hydraulic fracturing potential and stress paths. It is shown that the control of water level is an important factor while operating dams.

Dynamics of Water Environmental Factors and Phytoplankton Before and After Inflow of Seawater in Shingwa Reservoir (시화호에서 해수유입 전.후의 수환경 요인과 식물플랑크톤 동태)

  • 신재기;김동섭;조경제
    • Journal of Environmental Science International
    • /
    • v.9 no.2
    • /
    • pp.115-123
    • /
    • 2000
  • The dynamics of water quality and phytoplankton population had examined by monthly sampling from the upper to the lower part of watergate in an artificial Shihwa Reservoir in which situated near newly cities and incustrial complex on the west coast of Korea from January 1997 to December 1998. Among environmental factors, yearly average concentration of chl-a, TN and TP seemed to eutrophic or hypertrophic conditions that ranged 146.4~245.8 $\mu\textrm{g}$/$\ell$, 1.6~2.7 mg N/$\ell$, 258~448 $\mu\textrm{g}$ P/$\ell$, 26.9~80.7 $\mu\textrm{g}$/$\ell$, 1.0~2.4 mgN/$\ell$ and 74~239 $\mu\textrm{g}$P/$\ell$ respectively. Water quality was extremely deteriorated to consistently accumulation into inner reservoir by load of pollutants from autochthonous and allochthonous until early July 1997 after embankment. Water pollution of Shihwa Reservoir was remarkble on the biological condition with largely persistent bloom of phytoplankton and increase rate of standing crops was 2.4/yr. The development trend of phytoplankton in water ecosystem were closely related to increse and decrease of physico-chemical factors and those scale seemed to control by nutrient contents. Inflow of seawater into reservoir to object of repair of water quality. As to see dominant species, composition of those composed to mostly freshwater algae before inflow of seawater such as Selenastrum capricornutum of green algae, cyclotella atomus, C. meneghiniana of diatom and Microcystis spp. of blue-green algae and the other hand brackish algae were dominated after inflow of seawater such as Chaetoceros dicipiens, Skeletonema costatum of diatom, Dinophysis acuminata, Gymnodinium mikimotoi, G. sanguineum, Gyrodinium spirale, Prorocentrum minmum of dinoflagellate and Eutreptiella gymnastica of euglenoid. Moreover, small flagellates including Chroomonas spp. of cryptomonad were abundant throughout the year. The cause of water deterioration during fill of the freshwater were complexly supported with extra and intra parameters. The variation pattern of phytoplankton were related to water temperature and salinity by inflow of seawater based to plentiful nutrients. The dynamics of phytoplankton were assessed to ecosystem that clearly condition of dominant by unique or a few angel species seasonally.

  • PDF

Isothermal Characteristics of a Rectangular Parallelepiped Sodium Heat Pipe

  • Boo Joon Hong;Park Soo Yong
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.1044-1051
    • /
    • 2005
  • The isothermal characteristics of a rectangular parallelepiped sodium heat pipe were inves­tigated for high-temperature applications. The heat pipes was made of stainless steel of which the dimension was $140\;m\;(L)\;{\times}\;95m\;(W)\;{\times}\;46 m\;(H)$ and the thickness of the container was 5 mm. Both inner surfaces of evaporator and condenser were covered with screen meshes to help spread the liquid state working fluid. To provide additional path for the working fluid, a lattice structure covered with screen mesh wick was inserted in the heat pipe. The bottom surface of the heat pipe was heated by an electric heater and the top surface was cooled by circulating coolant. The concern in this study was to enhance the temperature uniformity at the bottom surface of the heat pipe while an uneven heat source up to 900 W was in contact. The temperature distribution over the bottom surface was monitored at more than twenty six locations. It was found that the operating performance of the sodium heat pipe was critically affected by the inner wall temperature of the condenser region where the working fluid may be changed to a solid phase unless the temperature was higher than its melting point. The maximum temperature difference across the bottom surface was observed to be $114^{\circ}C$ for 850 W thermal load and $100^{\circ}C$ coolant inlet temperature. The effects of fill charge ratio, coolant inlet temperature and operating temperature on thermal performance of heat pipe were analyzed and discussed.

Correlation between Analytic and Experimental Results on Inelastic Behavior of Reinforced Concrete Frame

  • Lee, Han-Seon;Kim, Sang-Dae;Park, Cheol-Yong;Ko, Dong-Woo
    • International Journal of Concrete Structures and Materials
    • /
    • v.18 no.3E
    • /
    • pp.173-181
    • /
    • 2006
  • The objectives of this study are to evaluate the reliability of an existing nonlinear analysis program for predicting the inelastic behavior of reinforced concrete frame with seismic details and to observe the redistribution of the internal forces, which can not be easily measured by an experiment. In order to carry out this task, the nonlinear analysis program of IDARC 2D(3) was run on a 2-bay, 2-story moment-resisting reinforced concrete plane frame with seismic details. (1) The effort to obtain the results of the analysis similar to those of experiment was made by determining the appropriate values of model parameters. The comparison of the analysis results with those of experiment and the observation of the distribution of internal forces obtained through nonlinear analysis points to the following conclusions. (1) The overall relationship between lateral load and lateral displacement given by the analysis is similar to that of experiment. However, the values of initial stiffness and the amount of energy dissipation in the initial displacement steps given by the analysis show larger values than those of experiment. (2) The analysis provided detailed information on the distribution and redistribution of internal forces and proved useful in elucidating the crack pattern, the sequence of the occurrence of plastic hinges, and the failure or yielding mechanism for the whole structure. (3) In spite of the similarity in overall behavior of analysis and experiment, there exists a significant discrepancy in some local behaviors. Furthermore, the hysteresis in the relationship between moment and curvature in some column ends have shown sudden deteriorations in strength, which can not be interpreted satisfactorily at the present time. Therefore, it is necessary to develop a better analytical model to fill this knowledge gap.

Settlement and Sliding Possibility of the Foundation of the Waste Landfill Constructed on Natural Marine Clay (자연 해성점토 위에 건설한 폐기물매립장 기호지반의 침하와 활동 가능성)

  • 김수삼;강기민
    • Geotechnical Engineering
    • /
    • v.12 no.5
    • /
    • pp.41-54
    • /
    • 1996
  • In this paper, the consolidation settlement of the landfill foundation during and after the period of disposal is analyzed using the program CONSOL which can include the influence of waste load and the leachate level into the analysis. the stability analysis of the embankment is also performed under the varied strength of foundation soil which results from the increase of effective stress due to consolidation of the clay under the landfill. The predicted settlement from CONSOL is compared with the field measured settlement. The results show that, when the leachate level increases with the increase of waste height, the increase of the effective stress of foundation clay is negligible and the stability of the slope of the landfill may not be secured as the disposal of the waste proceeds. Several complementary repairworks, e. g. the reduction of current slope of the fill, application of drain methods to stop or reduce !he leachate level are recommended. The predicted settlement consists moderately with the field measured settlement.

  • PDF

A Study on the Evaluation of Tension-Compression Fatigue Characteristics of Glass Fiber/Epoxy 4-Harness Satin Woven Laminate Composite for the Railway Bogie Application (철도차량 대차 적용 유리섬유/에폭시 4-매 주자직 적층 복합재의 인장-압축 피로특성 평가 연구)

  • Jeon, Kwang-Woo;Shin, Kwang-Bok;Kim, Jung-Seok
    • Composites Research
    • /
    • v.23 no.5
    • /
    • pp.22-29
    • /
    • 2010
  • This paper describes the evaluations of tension-compression fatigue characteristics and life for glass fiber/epoxy laminate composite applied to railway bogie to reduce weight. Test samples of tension-compression fatigue were composed of glass fiber/epoxy 4-harness woven laminate composites with different stacking sequence of warp-direction, fill-direction and ${\pm}45^{\circ}$-direction. The tension-compression fatigue test was conducted with stress ratio (R) of -1 and frequency of 5Hz. Goodman diagram were used to evaluate the fatigue characteristics and life of glass fiber/epoxy 4-harness satin woven laminate composite. Anti-buckling jig was designed to prevent buckling of specimen under compression load. The test results showed that the fatigue characteristics of glass fiber/epoxy 4-harness satin woven laminate composite with stacking sequence of warp-direction had a good performance in comparison with that of SM490 used to conventional metal railway bogie.

On the Performance Enhancements of VC Merging-capable Scheduler for MPLS Routers by Sequence Skipping Method (Sequence Skipping 방법을 이용한 MPLS 라우터의 VC 통합기능 스케쥴러의 성능 향상에 관한 연구)

  • Baek, Seung-Chan;Park, Do-Yong;Kim, Young-Beom
    • Journal of IKEEE
    • /
    • v.5 no.1 s.8
    • /
    • pp.111-120
    • /
    • 2001
  • VC merging involves distinguishing cells from an identical merged VC label. Various approaches have been proposed to help this identification process. However, most of them incur additional buffering, protocol overhead and/or variable delay. They make the provision of QoS difficult to achieve. So it was proposed a merge capable scheduler to support VC-merging (VCMS). However, in situations where all VCs are to be merged or the incoming traffic load is very low, it could happen that there are not enough non-merging cells to snoop. In this situation the scheduler uses special control cells to fill the empty time slots out. Too many control cells can cause high cell loss ratio and an additional packet transfer delay. To overcome the drawbacks, we propose a Sequence Skipping(SS) method where the sequencers skip the empty queues and insert SS cells. We show SS method is suitable for VC-merging and can reduce the cell loss ratio and the mean packet transfer delay through simulations.

  • PDF

The Data Generation for the V&V of KNPEC-2 Simulator with Best-estimated Codes (최적평가용 전산 코드를 이용한 원자력교육원 2호기 시뮬레이터 검증용 데이터 생산)

  • 김요한;이동혁;이명수
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2000.11a
    • /
    • pp.61-66
    • /
    • 2000
  • The KEPRI has been upgrading the KNPEC(Korea Nuclear Power Education Center) #2 simulator, a replica of Yonggwang Unit 1 & 2, due to the outdated systems. The scenarios, such as the continuous load change, are selected to verify and validate the simulator, and the data required to V&V are generated with the best-estimated codes, RETRAN and MARS. The reactor coolant system and steam generator system are cut up into volumes and junctions for the accurate model of the scenarios, and other components and control systems are modeled. For the model the operation and design data of the plants is used and in some cases the data of Kori Unit 3 & 4 is used to fill up the lack of required data. The results of some selected analyses with the models are compared with the operating data of the plants to verify the models, and the analyses of the scenarios are carried out to generated the data for the V&V of the simulator

  • PDF

Experimental Study on Bond Behavior of 1/12.5 Scale Model of the Steel Tubular Joint Connection Subjected to Compressive Loads (압축하중을 받는 1/12.5 축소모형 강관 연결부의 부착전단 거동에 대한 실험적 연구)

  • Hongseob Oh
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.3
    • /
    • pp.19-26
    • /
    • 2024
  • In this study, the compressive behavior of a 1/12.5 scale model of a wind tower support structure connection was experimentally analyzed. A high-performance cementitious grout with a compressive strength of 140 MPa was used to fill the connection, and experiments were conducted with shear key spacing, the shape, and connection length as variables. When the number of shear keys in the connection is the same, the smaller the spacing of the shear keys than the length of the connection, the higher the shear strength, and for the same spacing and connection length, the higher the height of the shear keys, the higher the strength. In addition, it was found that the strength showed a linear behaviour until the connection slip reached 1.0 mm, and it reached the maximum strength at 7.0 mm connection slip showing a non-linear behaviour as the load increased. It was found that the failure mode changed from interfacial shear failure to grout failure as the strength increased according to the shape and spacing of the shear key, and brittle failure did not occur due to steel fibers.

Filed Applicability Evaluations of Restoration Material for Underground Cavities Formed by Ground Subsidence (지반침하로 인한 지하공동 복구재료의 현장적용성 평가)

  • Bang, Seongtaek;Baek, Seungju
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.3
    • /
    • pp.5-11
    • /
    • 2020
  • Recently, ground pits that have been occurring frequently in urban areas are hindering traffic flow and causing property damages and loss of human life, acting as factors that are threatening the safety of citizens. Therefore, sunken ground must be quickly restored and provisions must be made for additional damage but current domestic detailed standards regarding ground pits and accurate definitions regarding causes and measures to be taken for reoccurrences are lacking. Restoration methods of sunken ground include backfilling by reusing sunken soil or other fill material and paving the road and while this is the most often used method, this only prevents ground from sinking temporarily and can not serve as a fundamental solution. Also, additional ground pits can occur on ground that is reinforced using this method due to faulty backfill material or faulty hardening. This study used Eco-friendly High-Strength Material (EHSM) as restoration material that can be used in the restoration of underground cavities that have occurred due to ground subsidence to analyze the engineered characteristics of modified dredging clay and test pieces made from changed ratios of EHSM and weathered granite soil were uniaxial compression tests were conducted and freezing-thawing tests were conducted to study strength properties according to environmental changes of restoration material, and after tests were concluded by each level, uniaxial compression tests and dynamic elasticity tests were conducted for intensity analysis. Also, to evaluate strength characteristics of the restored ground, dynamic plate load tests were conducted to verify the improvement effectiveness of the restored ground.