• Title/Summary/Keyword: Field test data

Search Result 2,431, Processing Time 0.025 seconds

Filter Test for Detecting Partial Discharge in XLPE Cable (XLPE 케이블의 PD 검출 필터 시험)

  • Cho, Jae-Chul;Choi, Yong-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.218-221
    • /
    • 2008
  • Due to a variable noises in the field underground lines, clear technology of noises is very important in the diagnosis technology of partial discharge. Therefore we progressed filter test to improve the measuring test of partial discharge in a field. We applied to field test after making W-LC filter for partial discharge measurement, and then designed experimental environment such as under- ground distribution lines of field. Measuring sensor for test was UHF sensor. And we analysed those using the Lemke Probe and oscilloscope (TDS-3054, Tektro- nix). Finally, we obtained excellent data of noise decrement in the joint box of 22.9[kV] distribution lines from above experiment.

  • PDF

Filter Test for Detecting Partial Discharge in XLPE Cable (XLPE 케이블의 PD 검출 필터 시험)

  • Kim, Dae-Yeol;Yun, Ju-Ho;Choi, Yong-Sung;Park, Dae-Hee;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.72-74
    • /
    • 2007
  • Due to a variable noises in the field underground lines, clear technology of noises is very important in the diagnosis technology of partial discharge. Therefore we progressed filter test to improve the measuring test of partial discharge in a field. We applied to field test after making W-LC filter for partial discharge measurement, and then designed experimental environment such as underground distribution lines of field. Measuring sensor for test was UHF sensor. And we analysed those using the Lemke Probe and oscilloscope (TDS-3054, Tektronix). Finally, we obtained excellent data of noise decrement in the joint box of 22.9[kV] distribution lines from above experiment.

  • PDF

Filter Test for Detecting Partial Discharge in 22.9kV XLPE Cable (22.9kV XLPE 케이블 PD 검출용 필터 시험)

  • Lee, Yong-Sung;Kim, Jung-Yoon;Kim, Seok-Jung;Lee, Kyoung-Yong;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2277-2279
    • /
    • 2005
  • Due to a variable noises in the field underground lines, clear technology of noises is very important in the diagnosis technology of partial discharge. Therefore we progressed filter test to improve the measuring test of partial discharge in a field. We applied to field test after making W-LC filter for partial discharge measurement, and then designed experimental environment such as under-ground distribution lines of field. Measuring sensor for test was UHF sensor. And we analysed those using the Lemke Probe and oscilloscope (TDS-3054, Tektronix). Finally, we obtained excellent data of noise decrement in the joint box of 22.9[kV] distribution lines from above experiment.

  • PDF

Safety Evaluation through Field Load Test of RC Slab Bridge (RC 슬래브 교량의 현장재하시험을 통한 안전성 평가)

  • Cho, Han-Min
    • Journal of Urban Science
    • /
    • v.11 no.1
    • /
    • pp.9-13
    • /
    • 2022
  • Currently, RC slab bridges in use in Korea account for most of the total bridges, and bridges with a service life of 20 years or more account for about 75%. However, most of these RC slab bridges have a span of less than 20m and are not included in the first and second types of facilities, so maintenance is very neglected. Therefore, in this study, field load test is performed on an aged RC slab bridge, and the performance evaluation is performed based on the structural response results (deflection, impact coefficient, natural frequency, etc.) of the bridge obtained through field load test. In addition, the performance evaluation results obtained through the load test are intended to be used as basic data for the damage evaluation process of the bridge currently under development.

Estimation of coefficient of consolidation in soft soils using PCPT dissipation results (피에조콘 소산곡선을 이용한 연약지반의 압밀계수 산정)

  • Seo, Kyung-Bum;Cho, Sung-Hwan;Lee, Jun-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1015-1023
    • /
    • 2010
  • While various PCPT-based methods for the analysis of consolidation were developed, additional laboratory test is needed to estimate the coefficient of consolidation. In this paper, hyperbolic method using PCPT dissipation curve for the estimation of coefficient of consolidation was proposed. To verify proposed method, field settlement test data and PCPT dissipation test data at same site were collected and analyzed. It is observed that proposed method shows good agreement with measured field settlement data.

  • PDF

A Study on Field-to-lab Test Method for the Safe Transport and Optimum Packaging Design of the Parcel Delivery in Korea (국내 택배화물의 안전운송 및 적정포장을 위한 Field-to-Lab 시험방법 연구)

  • Oh, Jae Young;Suh, Sang Uk;Lim, Mijin
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.2
    • /
    • pp.127-132
    • /
    • 2022
  • The growth of e-commerce market requires more delivery packagings, which protect goods from the damage factors on the delivery. In this study, we have analyzed the distribution environment data (vibration and impact) measured in previous study and compared with global standards (ISTA, ASTM), so that we developed the testing method for Field-to-Lab simulation suitable to the domestic delivery. In order to verify the efficacy of this method, we took the Field-to-Lab tests for 3 packaged products (detergents set, glass tableware set, small furniture), which has been frequent breakages or damages on the actual delivery by e-commerce order, so that we could find out the test results were similar to those of the actual delivery occasions. In addition, we could perform redesign and improvement of the parcel delivery packagings for safe transportation by taking this Field-to-Lab test repeatedly. This test methods was finally proposed to be Korean industrial standard (KS), and is expected to be useful as a designing tool for the packaging optimization between protecting goods and reducing packaging waste.

Evaluation of Bridge Load Carrying Capacity of PSC Girder Bridge using Pseudo-Static Load Test (의사정적재하시험을 이용한 PSC 거더교의 공용 내하력평가)

  • Yoon, Sang-Gwi;Shin, Soobong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.53-60
    • /
    • 2019
  • In this study, a method for updating the finite element model of bridges with genetic algorithm using static displacement were presented, and verified this method using field test data for PSC girder bridge. As a field test, static load test and pseudo-static load test were conducted, and updated the finite element model of test bridge using each test data. Finally, evaluated the bridge load carrying capacity with updated model using pseudo-static load test's displacement data. To evaluate the bridge load carrying capacity, KHBDC-LSD, KHBDC and AASHTO LRFD's live load model were used, and compared the each results.

A Method of Failure Detection Rate Calculation for Setting up of Guided Missile Periodic Test and Application Case (유도탄 점검주기 설정을 위한 고장 탐지율 산출 방안 및 적용 사례)

  • Choi, In-Duck
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.42 no.2
    • /
    • pp.28-35
    • /
    • 2019
  • Since guided missiles with the characteristics of the one-shot system remain stored throughout their entire life cycle, it is important to maintain their storage reliability until the launch. As part of maintaining storage reliability, period of preventive test is set up to perform preventive periodic test, in this case failure detection rate has a great effect on setting up period of preventive test to maintain storage reliability. The proposed method utilizes failure rate predicted by the software on the basis of MIL-HDBK-217F and failure mode analyzed through FMEA (Failure Mode and Effect Analysis) using data generated from the actual field. The failure detection rate of using the proposed method is applied to set periodic test of the actual guided missile. The proposed method in this paper has advantages in accuracy and objectivity because it utilizes a large amount of data generated in the actual field.

The Useful Techniques to Determine the Prior Odds and the Likelihood Ratios Bayesian Processor in Built-In-Test System

  • Yoo, Wang-Jin;Kim, Kyeong Taek
    • Journal of Korean Society for Quality Management
    • /
    • v.24 no.1
    • /
    • pp.61-72
    • /
    • 1996
  • It is very important to determine the likelihood ratios and the prior odds for designing a Bayesian processor in Built-In-Test system. Using traditional statistics, it is not difficult to determine the initial prior odds from the field data. For a newly designed system, development testing data or laboratory testing data could be used to replace field data. The likelihood ratios which playa key role in the Bayesian processor must be carefully determined, based on laboratory testing and statistical techniques. In this paper, expressing and determining the likelihood ratios by Geometric areas, Test, and Analytical method will be presented.

  • PDF

A Study on the Evaluation of Turbine Efficiency through the Performance Test of New Power Plant (신규 화력발전소의 성능 시험을 통한 터빈 효율의 평가에 관한 연구)

  • Kweon, Y.S.;Chung, H.T.;Jung, Y.B.
    • Journal of Power System Engineering
    • /
    • v.5 no.1
    • /
    • pp.11-20
    • /
    • 2001
  • Super-critical type steam power plant, which operates with steam pressure above the super-critical point, has a good reputation recently and is adopted as a new standard of the Korean Electric Power Corporation. The reason for the good reputation lies in it's superior power efficiency. However, the field data of the new power plant for the verification of it's performance are still insufficient, and more empirical data are needed to acquire technologies on the effective operation of it. In this study, the authors analyzed the field test data on power efficiencies got in a super-critical type steam power plant, and evaluated the excellency of the new plant by comparing the efficiency data with the one got in a conventional sub-critical type steam power plant.

  • PDF