• 제목/요약/키워드: Field test

검색결과 9,429건 처리시간 0.041초

직류철도차량에 대한 자계측정 및 분석 (Measurement and Analysis of Electromagnetic field for DC electric railway train)

  • 장동욱;김민철;이장무;한문섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1637-1639
    • /
    • 2005
  • The measurement of magnetic field is performed about DC and AC magnetic field in test track of depot. The test point is cap, on the converter/inverter box, on the traction motor, on the APSE and on the line filter, the height of measurement is bottom and 50 cm height. In case of AC magnetic field, the selected specific frequency is measured on the converter/inverter box. The AC magnetic field is checked and analysis through RS-232C and notebook PC. The DC magnetic field is measured by using the Hall Probe, test result is saved and analysis by PXI system. On the line filter, the maximum value is 1.4 mT in case of DC magnetic field and 0.044 mT in case of AC magnetic field at 50 Hz.

  • PDF

수치해석을 이용한 철도차량 동특성 주행시험기 활용성 기초 검토 (The Basic Applicability Study of the Roller Test Rig using Numerical Analysis)

  • 정우진;정흥채
    • 한국철도학회논문집
    • /
    • 제8권1호
    • /
    • pp.101-109
    • /
    • 2005
  • Roller test rig is the test facility for acquiring the data related dynamic characteristics of rolling stocks handily. The test method using roller test rig could be convenient to Set information about hunting and others rather than using field test. However, adopting this method brings about the inconvenient calibration process for measured data. This kind of additional effort results from the difference of contact condition between field test and test roller rig. In this paper, the numerical approach is used to get the amount of calibration. The analysis results of the field test are compared with results of the roller test rig to know what kind of alternation happens according to the change of contact condition.

PQM 및 PQMS 성능검증을 위한 실증시험 (The field-test of Power Quality Meter and Power Management System in order to verify the performance)

  • 최선규;송일근;권태호;한재욱
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.235-239
    • /
    • 2005
  • This paper gives a field-test method and result of PQM(Power Quality Meter) and PQMS(Power Quality Management System). The field-test was carried out as our own method. So, the test method has several kinds of improvement in this paper because it is first time to try the field-test of the equipment. However, we expect that the test result of PQM & PQMS has been used as a reference data which makes a scheme of evaluating performance of the equipment that has been used or is developed.

  • PDF

자동순항제어기에 의한 안전도 향상 효과 분석 (Evaluation of the Safety impact by Adaptive Cruise Control System)

  • 이태영;이경수;이찬규;이재완
    • 자동차안전학회지
    • /
    • 제4권1호
    • /
    • pp.5-11
    • /
    • 2012
  • This paper discusses the evaluation of the safety impact of the Adaptive Cruise Control (ACC) system in Korea. To evaluate the safety impact, this paper suggests an analysis method by using the test scenario and field operational test data. The test scenario is composed to represent the main component factor of the ACC system and ACC related accident situation such as rear-end collision, lane-change, and road-curvature, etc. Also, from the field operation test data, the system's potential to increase the safety can be measured ideally. Besides, field operational testdata was used to revise the expected safety impact value as Korean road conditions. By using the proposed evaluation method, enhanced safety impact of the ACC system can be estimated scientifically.

광대역통합망 구축을 위한 HFC망의 활용 가능성 연구 (A Study of HFC Network quality as BcN(Broadband convergence Network) access network.)

  • 김태웅;정무일;김홍익;임준순;박승권
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.167-170
    • /
    • 2005
  • We performed field test and analyzed results of field test in variable HFC(Hybrid Fiber Coaxial) network environments. And we investigated whether the test results is satisfied in DOCSIS(Data-over-Cable Service Interface Specification) 2.0 and OpenCable standard. Also, we propose HFC improvement problem for HFC Network quality as BcN(Broadband convergence Network) access network. We tested three sample areas. The sample areas represent various type of SO(System Operator) in korea. The field test was to measure signal level about digital channels. In results of multiple digital channels, in case of "Equalizer ON", we could be obtained very good test results. The results of field test were shown in satisfying recommended values in DOCSIS 2.0 and OpenCable. So, we could have confidence through field test that BcN will be possible to be adapted to environment of korea HFC network.

  • PDF

무시멘트 상온 재활용 아스팔트 기층의 현장 적용성을 통한 양생기간에 관한 연구 (Study of the Curing Time of Cementless Cold Central Plant Recycled Asphalt Base-Layer through Field-Application Review)

  • 최준성;정철호;이찬희;임인수
    • 한국도로학회논문집
    • /
    • 제19권2호
    • /
    • pp.67-74
    • /
    • 2017
  • PURPOSES : The objective of this study is to ascertain the curing period of cementless cold central plant recycled asphalt base-layer, using mechanical analyses and specimen quality tests on the field. METHODS : Cold central plant recycled asphalt base-layer mixture was produced in the plant from reclaimed asphalt, natural aggregate, filler for the cold mix, and the modified emulsion AP using asphalt mix design and plant mix design. In order to examine the applicability of the curing period during the field test, the international standards for the possibility of core extraction and the degree of compaction and LFWD deflection were analyzed. Moreover, Marshall stability test, porosity test, and indirect tensile strength test were performed on the specimens of asphalt mix and plant mix design. RESULTS : The plant production process and compaction method of cementless cold central plant recycled asphalt base-layer were established, and the applicability of the optical moisture content for producing the mixture was verified through the field test. In addition, it was determined that the core extraction method of the conventional international curing standard was insufficient to ensure performance, and the LFWD test demonstrated that the deflection converges after a two-day curing. However, the back-calculation analysis reveals that a three-day curing is satisfactory, resulting in a general level of performance of dense asphalt base-layer. Moreover, from the result of the specimen quality test of the asphalt mix design and plant mix design according to the curing period, it was determined that the qualities satisfied both domestic and international standards, after a two-day curing. However, it was determined that the strength and stiffness after three-day curing are higher than those after a two-day curing by approximately 3.5 % and 20 %, respectively. CONCLUSIONS:A three-day curing period is proposed for the cementless cold central plant recycled asphalt base-layer; this curing period can be demonstrated to retain the modulus of asphalt-base layer in the field and ensure stable quality characteristics.

대관령 풍력실증단지 및 실증연구 소개 (Introduction to Daegwallyeong Wind Turbine Test Site and Field Test Study)

  • 유능수;남윤수;이정완
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.5-8
    • /
    • 2005
  • This paper aims to introduce the Daegwallyeong wind turbine test site which is the first official wind turbine test site in Korea. The current status of test site, the characteristics, the projects performed and future plan of this test site are described. The results of wind condition measurements and monitoring system established by the Kangwon National University are presented. The importance of field test is also commented.

  • PDF

사력댐 동적물성 추정을 위한 현장조사기법 적용 및 분석 (Application and Analysis of Field Test and Geophysical Exploration for Dynamic Material Properties of Rockfill Dam)

  • 이종욱;김기영;전제성;조성은
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 지반공학 공동 학술발표회
    • /
    • pp.352-359
    • /
    • 2005
  • In this study, seismic refraction survey and MASW at dam crest and down-hole test and cross hole test in the boring holes located in dam crest through the core are performed to fin out dynamic material properties, are needed to evaluate dynamic safety of rockfill dam using dynamic analysis method. From the field test and geophysical exploration, applied such as above, p-wave and s-wave velocity profile of each layer of dam body. Dynamic material properties, such as elastic modulus, shear modulus, poissong's ration, are obtained from p-wave and s-wave velocity profile and density profile from formation density logging test.

  • PDF

DEVELOPMENT OF AN ACCELERATED LIFE TEST PROCEDURE FOR COOLING FAN MOTORS

  • Shin, W.G.;Lee, S.H.;Song, Y.S.
    • International Journal of Automotive Technology
    • /
    • 제7권6호
    • /
    • pp.757-762
    • /
    • 2006
  • Reliability of automotive parts has been one of the most interesting fields in the automotive industry. Especially, a small DC motor was issued because of the increasing adoption for passengers' safety and convenience. For several years, small DC motors have been studied and some problems of a life test method were found out. The field condition was not considered enough in the old life test method. It also needed a lot of test time. For precise life estimation and accelerated life test, new life test procedure was developed based on measured field condition. The vibration condition on vehicle and latent force on fan motor shaft were measured and correlated with each other. We converted the acceleration data into the load data and calculated the equivalent load from integrated value. We found the relationship which can be used for accelerated life test without changing the severity by using different loading factors.

콘크리트포장의 박층 콘크리트 덧씌우기공법 (Thin Bonded Concrete Overlay for Concrete Pavement Rehabilitation)

  • 윤경구;이형준;엄주용;서영찬
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.635-642
    • /
    • 1997
  • This research focused on the development of concrete overlay and test, which was conducted at 88 Highway 105k, 2 lanes of 290 m. The field application test consists of 6 cm and 10 cm bonded concrete overlay and 25 cm unbonded concrete overlay, using the slag cement for opening lanes for traffic early. The overlay were placed in a day. The whole period of traffic closing wes 8 day and it was reopened to traffic after concrete overlay has cured for 3 day. 5 cracks were founded when the field test section was investigated after 1 month, but all these may not make significant problems to overlay because these initiated and growed at the same line of repair section. The rideability and skid resistance become much better like in the new pavement after overlay. The structural capacity against deflection was much. which were verified by FWD(Falling Weight Deflectometer). The field test section is being used in a good condition and the results of field application and pavement performance analysis are encouraging. This rehabilitation methods may be adopted in Korea after a more field performance verifications.

  • PDF