• Title/Summary/Keyword: Field seismic test

Search Result 158, Processing Time 0.019 seconds

Dynamic Analysis of Existing Rockfill Dam Using Dynamic Properties by Field Test and Geophysical Exploration (실측 동적물성을 이용한 기존 사력댐의 동적거동분석)

  • Lee, Jong-Wook;Oh, Byung-Hyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.306-313
    • /
    • 2005
  • For seismic response analysis of rockfill dam, dynamic material properties, by field test, are needed. Density and elastic wave profiles have to be known to get an information of the material properties of structure. In this study, various field tests are applied to the example of rockfill dam to get an information of dynamic material properties and seismic safety is evaluated by seismic response analysis with the result of field tests.

  • PDF

Construction of Efficient Downhole Seismic Testing System by the Round Robin Test (상호검증시험을 통한 효율적인 다운홀 탄성파 기법 수행 시스템의 구성)

  • Bang, Eun-Seok;Kim, Ki-Seog;Kim, Dong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.4
    • /
    • pp.133-147
    • /
    • 2007
  • Downhole seismic method is very economic and easy of operation because it uses only one borehole and simple surface source to obtain the shear wave velocity ($V_s$) profile of a site. Even though it is widely used by the site investigation companies, universities and institutes, however, the $V_s$ profile determined by downhole seismic method has often low reliability due to employment of wrong combinations of field losing equipment and interpretation method and deficiency of experience. Round robin test was performed and testing equipment and procedure were compared. Adequate downhole seismic testing equipment was constructed based on the comparison and verification study of the round robin test. The data acquisition and software interpretation were also developed for automation and quick test in field. Finally, the effectiveness and applicability were verified through the field test by using the constructed testing system.

Development of Seismic Monitoring Analysis System for HANARO (하나로 지진감시 분석시스템 개발)

  • 류정수;김형규;윤두병
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.330-337
    • /
    • 2002
  • The HANARO seismic monitoring system is classified as non-nuclear safety(NNS), seismic category I, and quality class T The seismic monitoring system installed at the instrument room consists of five field sensors and one monitoring cabinet. The field sensors are composed of three triaxial accelerometers which installed at base slab, free field and overhead crane support respectively, a seismic trigger and a seismic switch at base slab. The most parts of analog system except field sensors are not produced any more, the improvement of the system is to be needed. The analog system with magnetic tape recorder is not only out-of-date model but dependent upon foreign technology. So it is difficult to get the spare parts and the cost to buy them is increased. Therefore we have improved the analog seismic monitoring system into a new digital seismic monitoring analysis system(SMAS) except five field sensors. After the installation of the new SMAS, we have carried out the site acceptance test(SAT) to confirm the field functions. The results of SAT satisfy the requirements of the fabrication technical specification. This new SMAS is operating at HANARO instrument room to acquire and analyse the signal of earthquake.

  • PDF

Estimation of Ripperbility in Rock Mass (암반의 굴착난이도 평가를 위한 제안)

  • 황영철;유병옥;김태수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.159-166
    • /
    • 1999
  • One of the most general methods that can evaluate the rippability is the seismic exploration. However, most field engineers have hardly used the seismic exploration. Instead of using the seismic exploration, they have usually used rock hammer and naked eyes to confirm the degree of rippability for soil, ripping rock and blasting rock. Therefore, to excavate the ground rationally, it is required to establish a quantitative criterion that can be used for distinguishing rippability. In this study, we find out the characteristics of rock strength through laboratory and field tests. The weathering condition of rock exposed to air due to excavation of soil layer and the variation of rock strength caused by weathering were investigated. A relationship between rock strength values that are obtained from uniaxial compression test, slaking durability test, point load test, schmidt hammer test and absorption ratio test is analyzed. The relationship is expressed in a form of equation by which we can evaluate the rock strengths obtained from simple laboratory and field tests. To evaluate rippability in a reasonable manner, a quantitative approach is proposed and a check list of rippability is developed based on the proposed methodology. It is recommended to modify the proposed method for evaluation of rippability in the field.

  • PDF

Application and Analysis of Field Test and Geophysical Exploration for Dynamic Material Properties of Rockfill Dam (사력댐 동적물성 추정을 위한 현장조사기법 적용 및 분석)

  • Lee, Jong-Wook;Kim, Ki-Young;Jeon, Je-Sung;Cho, Sung-Eun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.352-359
    • /
    • 2005
  • In this study, seismic refraction survey and MASW at dam crest and down-hole test and cross hole test in the boring holes located in dam crest through the core are performed to fin out dynamic material properties, are needed to evaluate dynamic safety of rockfill dam using dynamic analysis method. From the field test and geophysical exploration, applied such as above, p-wave and s-wave velocity profile of each layer of dam body. Dynamic material properties, such as elastic modulus, shear modulus, poissong's ration, are obtained from p-wave and s-wave velocity profile and density profile from formation density logging test.

  • PDF

Development of Data Analysis Method for Surface Wave Test (표면파 지반 탐사를 위한 새로운 신호 처리기법의 개발)

  • Park, Hyung-Choon;Kim, Dong-Soo;Cho, Sung-Eun
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.237-240
    • /
    • 2007
  • The evaluation of shear modulus (or shear wave velocity) profile of site is very important in the various fields of geotechnical engineering. To obtain shear wave velocity profile, various in-situ seismic methods using surface waves have been developed. These surface wave based in-situ seismic methods have their own strength and weakness. In this study, new seismic site characterization method using the harmonic wavelet analysis of wave (HWAW) was proposed to overcome some of weaknesses in the existing surface wave based seismic site characterization methods. HWAW method which is based on time-frequency analysis using harmonic wavelet transform have been developed to determine phase and group velocities of waves. In order to estimate the applicability of HWAW method, field tests were performed. Through field applications and comparison with other test results, the applicability of the proposed method were verified.

  • PDF

Evaluation of Seismic Loading of Pile Foundation Structure Considering Soil-foundation-structure Interaction (지반-기초-구조물 상호작용을 고려한 말뚝 기초 구조물에서의 지진 하중 평가)

  • Yoo, Min Taek;Ha, Jeong Gon;Jo, Seong-Bae;Kim, Dong Soo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.125-132
    • /
    • 2014
  • In this study, a series of dynamic centrifuge tests were performed for a soil-foundation-structural interaction system in dry sand with various embedded depths and superstructure conditions. Sinusoidal wave, sweep wave and real earthquake were used as input motion with various input acceleration and frequencies. Based on the results, a natural period and an earthquake load for soil-structure interaction system were evaluated by comparing the free-field and foundation accelerations. The natural period of free field is longer than that of the soil-foundation-structure system. In addition, it is confirmed that the earthquake load for soil-foundation-structure system is smaller than that of free-field in short period region. In contrast, the earthquake load for soil-foundation-structure interaction system is larger than that of free-field in long period region. Therefore, the current seismic design method, applying seismic loading of free-field to foundation, could overly underestimate seismic load and cause unsafe design for long period structures, such as high-rise buildings.

Study on Comparison of Methods for Estimation of Shear Wave Velocity in Core Zone of Existing Dam (기존 댐 코어죤의 전단파속도 산정기법 비교 연구)

  • Ha, Ik-Soo;Oh, Byung-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.10
    • /
    • pp.33-43
    • /
    • 2008
  • In this study, for the purpose of evaluating the shear wave velocity in core zone, cross-hole test, down-hole test, MASW (Multi-channel Analysis of Surface Wave), and seismic reflection survey were carried out on the crest of the existing 'Y' dam. The results of field tests were compared one another. Furthermore, the field test results were compared with the result by the Sawada's empirical recommendation method. The purpose of this study is to compare the results of four kinds of field tests for evaluation of shear wave velocity in core zone of existing dam, to verify applicability of the empirical method which was recommended by Sawada and Takahashi, and to recommend a reasonable method for evaluation of shear wave velocity which is needed to evaluate tile maximum shear modulus of core zone. From the results of four kinds of field tests such as cross-hole test, down-hole test, MASW, and seismic reflection survey, it was found that the shear wave velocity distributions were similar within 18 m in depth and the results obtained by MASW and seismic reflection survey were almost the same by 30 m in depth. For evaluation of shear wave velocity in core zone of the existing dam, in consideration that it is not easy to bore the hole ill the core zone of existing dam, surface surveys such as MASW and seismic reflection method are recommended as realistic methods. On condition that it is impossible to conduct the field test and it is preliminary investigation, it is recommended that Sawada's low bound empirical equation be used.

Evaluation of Shear Wave Velocity Profiles by Performing Uphole Test Using SPT (표준관입시험을 이용한 업홀시험에서 전단파 속도 주상도의 도출)

  • 김동수;방은석;서원석
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.2
    • /
    • pp.135-146
    • /
    • 2003
  • Uphole test is a seismic field test using receivers on ground surface and a source in depth. In this paper, the uphole test using SPT(standard penetration test) which is economical and reliable for obtaining shear wave velocity profile was introduced. In the proposed uphole test, SPT sampler which is common in site investigation, was used as a source and several 1Hz geophones in line were used as receivers. Test procedures in field and interpretation methods for obtaining interval times and for determining shear wave velocity profile considering refracted ray path were introduced. Finally, uphole test was performed at three sites, and the applicability of the proposed uphole test was verified by comparing wave velocity profiles determined by the uphole test with the profiles determined by downhole test, SASW test and SPT-N values.

Field testing of a seismically isolated concrete bridge

  • Chang, K.C.;Tsai, M.H.;Hwang, J.S.;Wei, S.S.
    • Structural Engineering and Mechanics
    • /
    • v.16 no.3
    • /
    • pp.241-257
    • /
    • 2003
  • The first seismically isolated structure in Taiwan was completed in early 1999. Seven new bridges of the Second National Freeway located at Bai-Ho area, a region which is considered to be of high seismic risk, have been designed and constructed with lead-rubber seismic isolation bearings. Since this is the first application of seismic isolation method to the practical construction in Taiwan, field tests were conducted for one of the seven bridges to evaluate the assumptions and uncertainties in the design and construction. The test program is composed of ambient vibration tests, forced vibration tests, and free vibration tests. For the free vibration tests, a special test setup composed of four 1000 kN hydraulic jacks and a quick-release mechanism was designed to perform the function of push-and-quick release. Valuable results have been obtained based on the correlation between measured and analytical data so that the analytical model can be calibrated. Based on the analytical correlation, it is concluded that the dynamic characteristics and free vibration behavior of the isolated bridge can be well captured when the nonlinear properties of the bearings are properly considered in the modeling.