• 제목/요약/키워드: Field performance test

검색결과 2,027건 처리시간 0.026초

고성능 콘크리트 현장 시험시공 (Field test of high-performance concrete)

  • 신동수;노재호;박연동;권영호;한정호;조일호;백명종
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.171-176
    • /
    • 1995
  • In recent years, Hith Performance Concrete has attracted world wide attention for its workability, strength and long-term durability. A field test was conducted to confirm the properties of high performance Concrete in situconditions. This paper describes the concrete materials, mix proportions, fresh state properties, some aspects of placability and qualty control results for field test. From the result, it was found that it is possible to produce High Performance Concrete with self-compactable and high strength.

  • PDF

현장방염처리제도의 실효성 확보 방안에 관한 연구 (A Study on the Ways of Securing the Effectiveness of Field Flame Retardant Coating Process)

  • 박성현;백은선
    • 한국화재소방학회논문지
    • /
    • 제25권2호
    • /
    • pp.95-100
    • /
    • 2011
  • 본 연구는 현장방염처리 물품에 대한 성능검사와 관련하여 불합리한 제도를 개선하고, 합리적인 방염성능검사 방법을 통하여 현장방염처리 물품에 대한 방염의 신뢰성을 확보하는데 궁극적인 목적이 있다. 이를 위해 최근 2년 동안 일선 소방관서에서 실시한 현장방염처리 물품에 대한 방염성능검사 실적을 토대로 최근에 사용되는 인테리어 마감자재 및 현장방염처리 경향에 대한 분석을 하였다. 또한 현장방염처리물품에 대한 성능검사 방법 및 절차, 방염처리업 등록제도의 문제점 등을 분석하여 현 실정에 적합한 방염성능검사 방법 및 성능검사의 신뢰성 확보를 위한 개선방안을 제시하고자 하였다.

저압 지중케이블 고장 위치 검출 실증 시험장 설계 및 구축 (Design and Construction of Test Field for Low Voltage Under Cable Fault Location Detection)

  • 오훈
    • 한국산학기술학회논문지
    • /
    • 제16권10호
    • /
    • pp.6666-6672
    • /
    • 2015
  • 전력 케이블의 고장에 대한 위치를 검출하기 위한 다양한 반사파 계측법들이 연구되고 있다. 하지만 대부분 관련 연구들이 시뮬레이션과 실험실에서의 성능 검증이 이루어지고 있고, 실제 현장과 비슷한 조건에서의 연구는 실증 시험장의 부재로 인해 이루어지지 못하고 있다. 따라서 본 논문에서는 케이블 고장 검출 장치의 표준화된 성능 시험과, 장비 운영 교육을 위한 실증 시험장을 설계 및 구축하였다. 구축된 실증시험장에서는 100m, 200m 거리에서 단선, 합선, 반단선, 접촉 불량 고장을 발생시켰고 최대 거리 측정 시험을 위해 1km 케이블을 설치하였다. 이러한 실증시험장은 향후 케이블 고장 검출 기술의 개발과 표준화, 그리고 장비 성능 검증 및 인증 시험 등을 위해 활용될 수 있을 것이다.

원방계 조건하에서의 레이다 성능평가를 위한 시뮬레이터 (A Simulator for Radar Performance Evaluation in a Far-Field Test Range)

  • 길민영;명로훈
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2005년도 종합학술발표회 논문집 Vol.15 No.1
    • /
    • pp.33-38
    • /
    • 2005
  • In this paper, a simulator for radar performance evaluation in a far-field test range is proposed, which can forecast maximum detection range, minimum detection range, number of test trials, resolution (range, azimuth, elevation) with input parameters before radar performance test and process results after. The proposed simulator is designed by Microsoft Foundation Class (MFC) of VC++ 6.0.

  • PDF

현장실험에서 음원의 입사각도에 따른 창의 차음성능 변화 (Variations of the Sound Insulation Performance of the Windows for the Sound Source Angle in the Field Test)

  • 김선우;김기용;이옥균;박현구;송혁
    • 소음진동
    • /
    • 제9권6호
    • /
    • pp.1180-1186
    • /
    • 1999
  • The aim of this study is to investigate the sound insulation performance of windows according to the sound source in the field test. For this purpose, an experiment was performed by KSF 2235(method for field measurements of sound insulation of windows and doors). Based on this code, the sound insulation performance fo the windows was measured for different incident angles of the sound and the effect of incident angle was obtained and discussed. Finally, it was found that the sound insulation performance of the windows was affected by the incident angle of sound source, and the sound insulation rating scale was different for the same window. The main factor changing insulation rating scale is considered to be the sound transmission through the carck of the folding part between the two pieces of wndows. Therefore, when evaluating the sound insulation performance of the windows for the field test, first of all the place of the sound source should be identified and generalized.

  • PDF

해양소수력발전소 튜블러 수차 성능평가를 위한 현장시험 (Field Test for Performance Evaluation of a Tubular Turbine in Marine Small Hydro Power Plant)

  • 황영호;이영호;최영도
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권8호
    • /
    • pp.1070-1077
    • /
    • 2011
  • 본 연구는 해양소수력발전소에서의 튜블러 수차의 성능평가를 위한 현장시험 및 그 결과에 대한 내용을 포함하고 있다. 현장시험용 수차의 발전기 최소출력은 측정된 유효낙차, 출력 그리고 효율을 이용하여 검토되었다. 정격 및 최대 출력시험은 수차 설치현장의 조수간만의 차에 의한 영으로 인하여 동일한 실험조건을 확보할 수 없었기 때문에 모델시험에 의한 성능 데이터를 이용하여 환산된 값을 사용하였다. 현장시험에 의한 수차의 성능은 최소출력, 정격출력, 최대출력 운전점에서 보증출력 및 보증효율을 만족시키는 결과를 나타냄을 확인하였다.

현장시험에 의한 소수력발전용 튜블러수차시스템 성능계측 (Performance Measurement of a Tubular Type Turbine System for Small Hydropower by Field Test)

  • 황영호;이영호;최영도
    • 한국유체기계학회 논문집
    • /
    • 제14권6호
    • /
    • pp.5-10
    • /
    • 2011
  • Recently, small hydropower attracts attention because of its renewable, clean and abundant energy resources to develop. Therefore, a tubular type hydro turbine is proposed for small hydropower in this study because the turbine has relatively simple structure and high possibility of applying to small hydropower. The purpose of this study is to investigate the performance characteristics of the turbine by field test. Field test iss conducted using one tubular turbine system as well as serial arrangement system by two tubular turbines taking into consideration of actual operation conditions. The results show that efficiency of test turbine changes considerably by the runner vane angle. Best efficiency of one turbine arrangement is higher than that of two turbine serial arrangement.

RC 슬래브 교량의 현장재하시험을 통한 안전성 평가 (Safety Evaluation through Field Load Test of RC Slab Bridge)

  • 조한민
    • 도시과학
    • /
    • 제11권1호
    • /
    • pp.9-13
    • /
    • 2022
  • Currently, RC slab bridges in use in Korea account for most of the total bridges, and bridges with a service life of 20 years or more account for about 75%. However, most of these RC slab bridges have a span of less than 20m and are not included in the first and second types of facilities, so maintenance is very neglected. Therefore, in this study, field load test is performed on an aged RC slab bridge, and the performance evaluation is performed based on the structural response results (deflection, impact coefficient, natural frequency, etc.) of the bridge obtained through field load test. In addition, the performance evaluation results obtained through the load test are intended to be used as basic data for the damage evaluation process of the bridge currently under development.

대형 트럭 반능동형 캐빈 공기 현가시스템의 승차감 성능 평가 연구 (Ride Performance Evaluation of a Heavy Truck Semi-active Cabin Air Suspension System)

  • 이지선;최규재;이광헌
    • 한국자동차공학회논문집
    • /
    • 제16권5호
    • /
    • pp.77-83
    • /
    • 2008
  • Semi-active cabin air suspension system improves driver's comfort by controlling the damping characteristics in accordance with driving situation. For the driver's comfort evaluation, test procedure has the two methodologies which are filed test and lab test. A field test method has a drawback. It requires a lot of time and money on repetitive test, due to the sensitivity of field test. On the other hand, the test with six axes simulation table at laboratory can obtain the repeatability of test, better than the field test method. In this paper, the procedures of ride performance test and control logic tuning with the table are presented. Drive files of the table can be represented with the almost same input condition as field test data. According to the result from the comparative test using six axes simulation table between passive and semi-active system by making ECU logic tuning, the RMS acceleration of semi-active cabin air suspension system was reduced by 29.6% compared with passive system.

현장 실험을 통한 Sputter Coating 컬러 BIPV 모듈의 발전성능 평가 (Performance Assessment of Sputter-Coating-Colored BIPV Modules Through Field Test)

  • 이효문;윤종호;김현일;이건환
    • 한국태양에너지학회 논문집
    • /
    • 제40권5호
    • /
    • pp.1-12
    • /
    • 2020
  • To assess the performance and characteristics of colored building-integrated photovoltaic (BIPV) modules, a comparative assessment of empirical performance was conducted on colored BIPV modules (gray, blue, and orange) and general BIPV module. These modules were installed on the south-facing slope (30°) for comparative assessment through a field test. Monitoring data were collected every 10 min from December 20, 2019 to January 21, 2020 and used to performance and characteristics analysis. Performance ratio and module efficiency were utilized during performance indexing for comparative assessment. For general BIPV modules, the operational efficiency was analyzed at 16.63%, whereas for colored BIPV modules, 13.70% (gray), 15.12 % (blue), and 14.49% (orange) were analyzed. It was discovered that the efficiency reduction caused by transmission losses owing to the application of colored cover glasses were 17.74% (gray), 9.05% (blue), and 9.86 % (orange), under field testing conditions. These values turned on an additional 7% reduction in efficiency for gray BIPV modules, compared to the degradation resulting from transmission drop (gray: 10.87%, blue: 8.99%, and orange: 9.02%) calculated using the efficiency of each module in standard test conditions (STC). Performance ratio analysis resulted in the following values: 0.92 for general BIPV modules, and 0.85 (gray), 0.91 (blue), and 0.91 (orange) for colored BIPV modules. As demonstrated by the above results, modules with a colored cover glass may differ in their operational performance depending on their color, unlike general modules. Therefore, in addition to the performance evaluation under STC, additional factors of degradation require consideration through field test.