• 제목/요약/키워드: Field monitoring

검색결과 2,607건 처리시간 0.029초

Near-field Noise-emission Modeling for Monitoring Multimedia Operations in Mobile Devices

  • Song, Eakhwan;Choi, Jieun;Lee, Young-Jun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제5권6호
    • /
    • pp.440-444
    • /
    • 2016
  • In this paper, an equivalent circuit model for near-field noise emission is proposed to implement a multimedia operation-monitoring system for mobile devices. The proposed model includes a magnetic field probe that captures noise emissions from multimedia components, and a transfer function for near-field noise coupling from a transmission line source to a magnetic field probe. The proposed model was empirically verified with transfer function measurements of near-field noise emissions from 10 kHz to 500 MHz. With the proposed model, a magnetic field probe was optimally designed for noise measurement on a camera module and an audio codec in a mobile device. It was demonstrated that the probe successfully captured the near-field noise emissions, depending on the operating conditions of the multimedia components, with enhanced sensitivity from a conventional reference probe.

UHF 기술을 이용한 온라인 부분방전 모니터링 (On-line Insulation Diagnostic by PD Monitoring Field Practical of UHF Technique for On-line PD Monitoring)

  • 오용;최용성;황종선;이경섭
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.176-180
    • /
    • 2008
  • A field-oriented UHF system for on-line PD monitoring of transformers is designed, which has been installed inside the oil tank of transformer in a substation by two ways: on-line installing mode through the oil-valve and pre-installing mode through the man hole/hand hole cover. This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

포터블 기반 스마트 구조 응답 모니터링 시스템 개발 및 현장 적용성 평가 (Development of a Portable-Based Smart Structural Response Monitoring System and Evaluation of Field Applicability)

  • 박상기;서동우;박기태;김호진
    • 한국방재안전학회논문집
    • /
    • 제16권4호
    • /
    • pp.147-156
    • /
    • 2023
  • 케이블 교량의 거동은 동적 응답에 의해 지배적이며 상대적으로 복잡하므로 교량의 상태를 평가하기 위한 장단기 현장 계측이 요구되는 경우가 빈번하다. 영구적인 SHMS(Structural Health Monitoring System)가 설치되지 않은 경우 성능평가를 위해 이동식 모니터링 시스템이 필요하다. 이 경우 교량의 위치와 형태에 따라 전력, 통신 등의 제한된 여건으로 인해 이동식 모니터링 시스템 운영에 어려움이 발생할 수 있다. 본 연구에서는 국내는 물론 동남아 지역 교량의 장 ‧ 단기 모니터링에 효과적으로 활용될 수 있는 포터블 기반의 스마트 구조응답 모니터링 시스템을 개발하였다. 개발된 시스템은 현장에서 자체 전원 공급 시스템을 이용하여 장시간 운용이 가능한 다채널 휴대용 데이터 수집 및 분석 장비이며, 실시간 데이터를 이용하여 케이블 교량의 동적 특성을 자동으로 분석할 수 있는 알고리즘을 탑재하고 있다. 개발된 시스템의 현장 적용성을 평가하기 위해 한국과 베트남의 케이블 교량에서 현장 실증을 수행하였으며, 이를 통해 개발된 시스템의 현장 운영의 신뢰성과 효율성을 확인하였고, 추가적으로 케이블 교량 모니터링 분야에서의 해외 시장 적용 가능성을 확인하였다.

재하시험을 통한 사장교의 케이블 장력 모니터링 시스템의 적용성 평가 (Evaluation of Applicability of Cable Force Monitoring System of Cable-stayed Bridge by Field Loading Test)

  • 김정훈;송재호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제13권1호통권53호
    • /
    • pp.205-213
    • /
    • 2009
  • 본 연구에서는 사장교의 케이블 장력을 장기적인 관점에서 보다 효과적으로 분석하고 모니터링할 수 있는 케이블 장력 모니터링 시스템을 개발하는 연구를 수행하였다. 제안된 모니터링 시스템에는 실시간 동적 데이터에서 일정 대상시간 동안의 가속도 데이터를 선정하고, 이를 고속 푸리에 변환 알고리즘에 적용하여 주파수 분석한 결과를 평균하여 일반화시키는 신호해석이론이 적용되었다. 제안된 케이블 장력의 모니터링 시스템의 적용성을 평가하기 위하여 실제 공용중인 사장교에 대한 현장재하시험을 실시하였다. 현장계측을 통한 수동으로 계산된 장력과 모니터링 시스템의 강제저장 기능을 통해 저장된 데이터를 수계산하여 반자동으로 계산된 장력을 비교한 결과, 장력차이가 1% 이내로 발생하였고, 제안된 모니터링 시스템에서 자동으로 계산된 장력을 비교한 결과에서는 약 5% 범위의 무시할만한 차이로 나타나 본 연구에서 제안된 사장교 케이블 장력 모니터링 시스템의 신뢰도를 검증하였다.

Envi-met 모델을 이용한 도심지역 대기오염측정망 주변의 바람장 분석 (An Analysis of Wind Field around the Air Quality Monitoring Station in the Urban Area by Using the Envi-met Model)

  • 김민경;이화운;도우곤;정우식
    • 한국환경과학회지
    • /
    • 제18권9호
    • /
    • pp.941-952
    • /
    • 2009
  • The urban microscale wind field around the air quality monitoring station was investigated in order to check how a building complex influences it. For this study as the high density areas Jwa-dong and Yeonsan-dong monitoring sites in Busan were chosen. As the direction of inflow which is perpendicular to the building of the monitoring station was expected to cause the considerable variation of the wind field, that direction was selected. The model Envi-met was used as the diagnostic numerical model for this study. It is suitable for this investigation because Envi-met has the microscale resolution. After simulating it, on the leeward side around a building complex the decrease of flow velocity and some of vortexes or circulation area were discovered. In addition, on the edge of the top at the building and at the back of the building the upward flow was developed. If the sampling hole of monitoring site were located in this upward flow, it would be under the influence of upward flow from the near street.

TV광고 모니터링을 위한 비디오 워터마킹 시스템의 설계에 관한 연구 (A Study on the design of Video Watermarking System for TV Advertisement Monitoring)

  • 신동환;김성환
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.206-213
    • /
    • 2007
  • In this paper, The monitoring system for TV advertisement is implemented using video watermark. The functions of the advertisement monitoring system are monitoring the time, length, and index of the on-air advertisement, saving the log data, and reporting the monitoring result. The performance of the video watermark used in this paper is tested for TV advertisement monitoring. This test includes LAB test and field test. LAB test is done in laboratory environment and field test in actually broadcasting environment. LAB test includes PSNR, distortion measure in image, and the watermark detection rate in the various attack environment such as AD/DA(analog to digital and digital to analog) conversion, noise addition, and MPEG compression. The result of LAB test is good for the TV advertisement monitoring. KOBACO and SBS are participated in the field test. The watermark detection rate is 100% in both the real-time processing and the saved the processing. The average deviation of the watermark detection time is 0.2 second, which is good because the permissible average error is 0.5 second.

해양구조물 전기방식시스템 현장적용실험장 설계 (Field Testing Center Design of Cathodic Protection System for Maritime Metallic Structures)

  • 하태현;배정효;이현구;하윤철;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.633-636
    • /
    • 2003
  • Most of maritime metallic structures are adopted a CP(Cathodic Protection) System for protection of corrosion in advanced country. So, we had been developed a remote corrosion monitoring control system. And we want to know the characteristics of efficiency, reliability, durability and so on. On the view point of it, we have to test in real field. in terms of design, cathodic protection systems, corrosion monitoring systems and optimal corrosion control systems compare to general commercial products. So, these systems have being studied to improve their capability. In this paper, the result of field testing center design of intelligent cathodic protection system including anodes, a real-time wireless remote corrosion monitoring and corrosion control system are described in naval ports.

  • PDF

Communication Redundancy for Reliability Improvement in an Industrial Monitoring and Control System

  • Rhyu, Keel-Soo;Chung, Kyung-Yul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권8호
    • /
    • pp.1291-1298
    • /
    • 2004
  • In development of monitoring and control systems, one of the most important points is to consider a redundancy so that the system can be operated normally although hardware faults are partly occurred. The purpose of this paper is to introduce a monitoring and control system with a redundancy function for I/O servers and communication networks. I/O servers composed with an active server and a standby server. Each server also has 3 communication ports, 2 ports of them were connected to field units and the other 1 port was connected to the other server. Field units have to be constructed to 2 communication ports connected I/O servers through communication lines. Also, server communication module was implemented for analyzing and handling fault elements. and was submodularized for linking easily with a monitoring and control module. An experiment with 2 servers and 2 field units was constructed to demonstrate its effectiveness.

Intraoperative Nerve Monitoring during Minimally Invasive Esophagectomy and 3-Field Lymphadenectomy: Safety, Efficacy, and Feasibility

  • Srinivas Kodaganur Gopinath;Sabita Jiwnani;Parthiban Valiyuthan;Swapnil Parab;Devayani Niyogi;Virendrakumar Tiwari;C. S. Pramesh
    • Journal of Chest Surgery
    • /
    • 제56권5호
    • /
    • pp.336-345
    • /
    • 2023
  • Background: The objective of this study was to demonstrate the safety, efficacy, and feasibility of intraoperative monitoring of the recurrent laryngeal nerves during thoracoscopic and robotic 3-field esophagectomy. Methods: This retrospective analysis details our initial experience using intraoperative nerve monitoring (IONM) during minimally invasive 3-field esophagectomy. Data were obtained from a prospectively maintained database and electronic medical records. The study included all patients who underwent minimally invasive (video-assisted thoracic surgery/robotic) transthoracic esophagectomy with neck anastomosis. The patients were divided into those who underwent IONM during the study period and a historical cohort who underwent 3-field esophagectomy without IONM at the same institution. Appropriate statistical tests were used to compare the 2 groups. Results: Twenty-four patients underwent nerve monitoring during minimally invasive 3-field esophagectomy. Of these, 15 patients underwent thoraco-laparoscopic operation, while 9 received a robot-assisted procedure. In the immediate postoperative period, 8 of 24 patients (33.3%) experienced vocal cord paralysis. Relative to a historical cohort from the same institution, who were treated with surgery without nerve monitoring in the preceding 5 years, a 26% reduction was observed in the nerve paralysis rate (p=0.08). On follow-up, 6 of the 8 patients with vocal cord paralysis reported a return to normal vocal function. Additionally, patients who underwent IONM exhibited a higher nodal yield and a decreased frequency of tracheostomy and bronchoscopy. Conclusion: The use of IONM during minimally invasive 3-field esophagectomy is safe and feasible. This technique has the potential to decrease the incidence of recurrent nerve palsy and increase nodal yield.

워터마크를 이용한 TV방송 광고모니터링 시스템 (Monitoring System for TV Advertisement Using Watermark)

  • 신동환;김경순;김종원;최종욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.15-18
    • /
    • 2004
  • In this paper, it is implemented the monitoring system for TV advertisement using video watermark. The functions of an advertisement monitoring system are automatically monitoring for the time, length, and index of the on-air advertisement, saving the log data, and reporting the monitoring result. The performance of the video watermark used in this paper is tested for TV advertisement monitoring. This test includes LAB test and field test. LAB test is done in laboratory environment and field test in actually broadcasting environment. LAB test includes PSNR, distortion measure in image, and the watermark detection rate in the various attack environment such as AD/DA(analog to digital and digital to analog) conversion, noise addition, and MPEG compression The result of LAB test is good for the TV advertisement monitoring. KOBACO and SBS are participated in the field test. The watermark detection rate is 100% in both the real-time processing and the saved file processing. The average deviation of the watermark detection time is 0.2 second, which is good because the permissible average error is 0.5 second.

  • PDF