• 제목/요약/키워드: Field instrumentation

검색결과 336건 처리시간 0.022초

Ultrasonic guided wave approach incorporating SAFE for detecting wire breakage in bridge cable

  • Zhang, Pengfei;Tang, Zhifeng;Duan, Yuanfeng;Yun, Chung Bang;Lv, Fuzai
    • Smart Structures and Systems
    • /
    • 제22권4호
    • /
    • pp.481-493
    • /
    • 2018
  • Ultrasonic guided waves have attracted increasing attention for non-destructive testing (NDT) and structural health monitoring (SHM) of bridge cables. They offer advantages like single measurement, wide coverage of acoustical field, and long-range propagation capability. To design defect detection systems, it is essential to understand how guided waves propagate in cables and how to select the optimal excitation frequency and mode. However, certain cable characteristics such as multiple wires, anchorage, and polyethylene (PE) sheath increase the complexity in analyzing the guided wave propagation. In this study, guided wave modes for multi-wire bridge cables are identified by using a semi-analytical finite element (SAFE) technique to obtain relevant dispersion curves. Numerical results indicated that the number of guided wave modes increases, the length of the flat region with a low frequency of L(0,1) mode becomes shorter, and the cutoff frequency for high order longitudinal wave modes becomes lower, as the number of steel wires in a cable increases. These findings were used in design of transducers for defect detection and selection of the optimal wave mode and frequency for subsequent experiments. A magnetostrictive transducer system was used to excite and detect the guided waves. The applicability of the proposed approach for detecting and locating wire breakages was demonstrated for a cable with 37 wires. The present ultrasonic guided wave method has been found to be very responsive to the number of brokenwires and is thus capable of detecting defects with varying sizes.

Quality Assessment of the Soils Used for Urban Agriculture in Seoul and its Vicinity

  • Lim, Ga-Hee;Park, Sol-Yi;Jeon, Da-Som;Yoon, Jung-Hwan;Lee, Dan-Bi;Oh, Jun-Seok;Kim, Kye-Hoon
    • 한국토양비료학회지
    • /
    • 제49권5호
    • /
    • pp.572-576
    • /
    • 2016
  • Soil quality assessment is an important tool for environmental management in an agricultural field. It can be used to evaluate the health of the soils and to establish the basis for sustainable urban agriculture and soil management. For this study, the chemical properties of the soils used for urban agriculture were examined. Results of the soil analysis for chemical properties were applied to soil quality assessment system, which is composed of principal component analysis, application to scoring function and derivation of soil quality index (SQI). Soil pH, electrical conductivity (EC), organic matter (OM), total nitrogen (T-N) were determined for minimum data set (MDS) according to principal component analysis. Based on the results of scoring for four indicators (pH, EC, OM, T-N), soil pH was the indicator that needs the most urgent management. Results of SQI derivation showed that many of the urban farms appeared to be insufficient score in comprehensive soil quality assessment. In conclusion, soil management practices based on scores derived from soil chemical indicators need to be carried out to maintain sustainable urban agricultural soil environment and to provide easy-to-understand information to urban farmers.

Outdoor Applications of Hyperspectral Imaging Technology for Monitoring Agricultural Crops: A Review

  • Ahmed, Mohammad Raju;Yasmin, Jannat;Mo, Changyeun;Lee, Hoonsoo;Kim, Moon S.;Hong, Soon-Jung;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • 제41권4호
    • /
    • pp.396-407
    • /
    • 2016
  • Background: Although hyperspectral imaging was originally introduced for military, remote sensing, and astrophysics applications, the use of analytical hyperspectral imaging techniques has been expanded to include monitoring of agricultural crops and commodities due to the broad range and highly specific and sensitive spectral information that can be acquired. Combining hyperspectral imaging with remote sensing expands the range of targets that can be analyzed. Results: Hyperspectral imaging technology can rapidly provide data suitable for monitoring a wide range of plant conditions such as plant stress, nitrogen status, infections, maturity index, and weed discrimination very rapidly, and its use in remote sensing allows for fast spatial coverage. Conclusions: This paper reviews current research on and potential applications of hyperspectral imaging and remote sensing for outdoor field monitoring of agricultural crops. The instrumentation and the fundamental concepts and approaches of hyperspectral imaging and remote sensing for agriculture are presented, along with more recent developments in agricultural monitoring applications. Also discussed are the challenges and limitations of outdoor applications of hyperspectral imaging technology such as illumination conditions and variations due to leaf and plant orientation.

데이터베이스를 활용한 센서 데이터 관리 (Sensor Data Management using Database)

  • 권대곤;최신형
    • 한국산학기술학회논문지
    • /
    • 제10권7호
    • /
    • pp.1608-1613
    • /
    • 2009
  • 임베디드 분야에 대한 발전으로 임베디드 시스템을 이용한 각종 장비가 개발되고, 실제 생활에 많은 부분에서 활용되고 있다. 또한, 무선센서네트워크를 통해 각종 센서로부터 데이터를 수집할 수 있으며, 호스트를 거치지 않더라도 임베디드 시스템만으로도 수집된 데이터를 실시간으로 보여줄 수 있다. 본 논문에서는 센서 노드로부터 무선으로 전송되는 센싱 데이터 관리를 위해 임베디드 시스템에 임베디드 데이터베이스를 설치하여 게이트웨이 역할만을 하는 임베디드 시스템의 기능을 개선한 방안을 제시한다. 즉, 임베디드 시스템에 임베디드 데이터베이스를 설치한 다음 센싱 데이터를 저장 및 관리함으로써 센싱 데이터가 전송될 때마다 게이트웨이를 통한 호스트와 통신하는 전송횟수를 줄일 수 있으며, 임베디드 시스템에서 필터링 프로그램을 수행하여 보다 정확하고 유효한 데이터만을 호스트에 전송함으로써 수집된 센싱 데이터에 기반한 분석결과의 신뢰성을 높일 수 있다.

위상 배열 고출력증폭기용 고밀도 고전압 전원공급기 하드웨어 구성 및 FPGA를 이용한 고속 독립 제어방식 (Hardware configuration of High-Density HVPS and High Speed independent Control method Using FPGA for Phased Array Transmitters)

  • 강춘호;이성욱;이홍학;이창훈;변기식
    • 한국정보통신학회논문지
    • /
    • 제19권11호
    • /
    • pp.2758-2764
    • /
    • 2015
  • 위상배열 고출력증폭기용 고전압전원공급기(HVPS)는 다출력 소용량 진행파관(TWT)을 구동하는데 반드시 독립운용 특성을 가져야만 한다. TWT 독립운용 특성은 어느 하나의 TWT가 고장이 발생한 경우에도 부분 송신기능을 유지함으로써 관련 임무를 중단 없이 수행하는 매우 중요한 요소로 알려져 있다. 본 논문에서는 소용량 TWT들을 독립 운용하기 위한 FE 변조부를 포함한 고밀도 HVPS 하드웨어 구성 및 FPGA를 이용한 고속 독립 제어방식에 관해 기술하였다. 또한, 위상배열 고출력증폭기 운용 중 발생 가능한 고장을 모의하여 안정적으로 고장이 발생한 TWT가 독립 제어되는 시험결과를 기술하였다.

Psychometric Evaluation of Uterine Cervical Cancer Screening Embarrassment Questionnaire among Korean Women: Complementary Use of Rasch Model

  • Cho, Eun-Jung;Chung, Bok-Yae;Lee, Kwan;Consedine, Nathan S.;Lee, Won-Kee
    • 여성건강간호학회지
    • /
    • 제17권5호
    • /
    • pp.463-473
    • /
    • 2011
  • Purpose: Cervical cancer can be prevented by regular cervical screening. Embarrassment has been reported as one important barrier to cervical screening uptake. The absence of appropriate instrumentation, however, has limited our understanding of the links between embarrassment and health care outcomes. The purpose of this study was to evaluate psychometric attributes of the uterine cervical cancer screening embarrassment questionnaire. Methods: A convenience sample for field study was recruited from four gynecological clinics in Gyeongju, Korea. Within a cross-sectional descriptive design, 339 women who had cervical screening completed self-administered measures of embarrassment including a visual analogue, general medical embarrassment, dispositional embarrassment, and Pap smear related negative emotion. Results: Rasch analysis of items demonstrated the evidence of one-dimensional construct and good 7-point rating scales functioning. Factor analysis revealed that uterine cervical cancer screening embarrassment was comprised of two domains-bodily manifestations and perceiving an undesirable social face. Construct validity was demonstrated by a high subscale-to-subscale correlation. Convergent and discriminant validity was evidenced by significant correlations with a 100 mm VAS scale, general medical embarrassment, and Pap smear related negative emotion. Known-group validity was established by comparing women with high versus low trait embarrassment. Both two sub-scales and overall scale demonstrated good internal reliability. Conclusion: The Uterine uterine cervical cancer screening questionnaire is a reliable and valid instrument suited to assessing the manifestations of embarrassment during screening. The use of instrument can be extended to understand the client's embarrassment undergoing health examinations which require the exposure of their private parts.

철도하부 가도교 설치에 대한 JES공법 (Joint Element Structure Method on the Subway Box Structure unere Railroad)

  • 피태희;조국환;사공명
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.973-981
    • /
    • 2008
  • This document presents the JES(Joint Element Structure) method that has been adopted for the firs time in our country for the construction of the structure crossing under the railroad without open excavation. Front Jacking Method, Tubular Roof Construction Method, New Tubular Roof Method and Joint Element Structure Method are commonly used for the construction of structures crossing under the railroad. JES Method, frequently used in Japan recently, is a new method to construct the structures crossing under the railroad in a safe manner and in a relatively short period of time by utilizing the steel elements with the joints through which the load in the vertical angle to the axial direction is transferred to the next element. The elements are tied to each other through the joints to form the permanent walls of a Rahmen structure under the road without open excavation and without limitation to the length in a convenient way. Through the case study in the project of a Subway Box Culvert Improvement for the Gyeonguiseon Railroad in front of Yonsei University using the JES Method, the cost and period of construction in various types of soil is investigated compared to the Front Jacking Method. Furthermore, by analyzing the results of instrumentation measurements carried out throughout the construction, comparison between the actual displacement in the ground and the predicted displacement in the design is made to provide the considerations to be counted for the design. In conclusion, comparison in the field of economic feasibility, constructability and safety between the JES Method and Front Jacking Method, which is most frequently adopted in our country at present, is made to present the JES Method as a new alternative for the non-open excavation construction method for the structures crossing under the railway.

  • PDF

Comparative analysis of turbulence models in hydraulic jumps

  • Lobosco, Raquel J.;da Fonseca, David O.;Jannuzzia, Graziella M.F.;Costa, Necesio G.
    • Coupled systems mechanics
    • /
    • 제8권4호
    • /
    • pp.339-350
    • /
    • 2019
  • A numerical simulation of the incompressible multiphase hydraulic jump flow was performed to compare the interface prediction through the use of the three RANS turbulence models: $k-{\varepsilon}$, $RNGk-{\varepsilon}$ and SST $k-{\omega}$. A three dimensional no submerged hydraulic jump and a two dimensional submerged hydraulic jump were modeled. Both the geometry and the mesh were created using the open source Gmsh code. The project's geometry consists of a rectangular channel with length and height differences between the two dimensional and three dimensional simulations. Uniform hexahedral cells were used for the mesh. Three refining meshes were constructed to allow to verify simulation convergence. The Volume of Fluid (abbr. VOF) method was used for treatment of the air-water surface. The turbulence models were evaluated in three distinct set up configurations to provide a greater accuracy in the flow representation. In the two-dimensional analysis of a submerged hydraulic jump simulation, the turbulence model RNG RNG $k-{\varepsilon}$ provided a better interface adjust with the experimental results than the model $k-{\varepsilon}$ and SST $k-{\omega}$. In the three-dimensional simulation of a no-submerged hydraulic jump the k-# showed better results than the SST $k-{\omega}$ and RNG $k-{\varepsilon}$ capturing the height and length of the ledge with a better fit with the experimental results.

기본 모드를 침해하는 과도 고장이 존재하는 입력/출력 비동기 순차 회로에 대한 내고장성 제어 (Fault-Tolerant Control of Input/Output Asynchronous Sequential Circuits with Transient Faults Violating Fundamental Mode)

  • 양정민;곽성우
    • 한국전자통신학회논문지
    • /
    • 제17권3호
    • /
    • pp.399-408
    • /
    • 2022
  • 본 논문에서는 기본 모드 원리를 침해하는 과도 고장이 존재하는 입력/출력 비동기 순차 회로의 내고장성 교정 제어 시스템을 제안한다. 비동기 순차 회로의 과도 천이 과정에서 발생하는 비-기본 모드 고장을 극복하기 위해서는 고장에 의한 상태 천이가 종료되는 시점을 알아야 하며, 회로를 고장 상태로부터 원래 도달해야 하는 상태와 출력 등가적인 상태로 보내기 위한 교정 동작을 구현해야 한다. 본 논문에서는 이러한 고장 탐지 및 극복을 구현할 수 있는 출력 피드백 교정 제어기의 존재 조건을 규명한다. FPGA 실험을 통해 제안된 제어 시스템의 설계 과정을 제시하고 응용 가능성을 검증한다.

Optimized TOF-PET detector using scintillation crystal array for brain imaging

  • Leem, Hyuntae;Choi, Yong;Jung, Jiwoong;Park, Kuntai;Kim, Yeonkyeong;Jung, Jin Ho
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2592-2598
    • /
    • 2022
  • Research groups in the field of PET instrumentation are studying time-of-flight(TOF) technology to improve the signal-to-noise ratio of PET images. Scintillation light transport and collection plays an important role in improving the coincidence resolving time(CRT) of PET detector based on a pixelated crystal array. Four crystal arrays were designed by the different optical reflection configuration such as external reflectors and surface treatment on the CRT and compared with the light output, energy resolution and CRT. The design proposed in the study was composed of 8 × 8 LYSO crystal array consisted of 3 × 3 × 15 mm3 pixels. The entrance side was roughened while the other five surfaces were polished. Four sides of all crystal pixels were wrapped with ESR-film, and the entrance surface was covered by Teflon-tape. The design provided an excellent timing resolution of 210 ps and improved the CRT by 16% compared to the conventional method using a polishing treatment and ESR-film. This study provided a method for improving the light output and CRT of a pixelated scintillation crystal-based brain TOF PET detector. The proposed configuration might be an attractive detector design for TOF brain PET requiring fast timing performance with high cost-effectiveness.