• Title/Summary/Keyword: Field exposure test

검색결과 160건 처리시간 0.029초

촉진열화 및 장기폭로시험에 의한 고성능 PC패널의 내구성능 및 열화특성 (Characterization of Durability of PC panel by Accelerating Test in Deterioration Chamber and Long-Term Field Exposure Test)

  • 마상준;장필성;최재석;주정민
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1549-1554
    • /
    • 2008
  • In this paper, The evaluation of durability of the PC Panel lining for tunnel structure was examined through the rapid test by carbonation and freezing and thawing. Also for the purpose of improvement of durability. Namely, the durable characteristics of PC Panel lining by carbonation and freezing and thawing, was evaluated by rapid test and long-term field exposure test and main influence factors were derived. As a result of test, Correlation of accelerating test in deterioration chamber and long-term field exposure test, it will be expected that the proposed correlation well to the prediction of life expectancy of structure and is contributed greatly in the future.

  • PDF

부식촉진실험을 이용한 강교용 무도장 강재의 부식내구성 평가 (Corrosion Durability Evaluation of Uncoated Structural Steel Using Accelerated Exposure Tests)

  • ;이토 요시토
    • 한국강구조학회 논문집
    • /
    • 제19권1호
    • /
    • pp.79-86
    • /
    • 2007
  • 도장, 용사 및 도금 등의 강교용 방청법의 장기내구성 평가에는 대기노출실험법이 사용되고 있으나, 노화데이터를 얻기까지는 수년에서 수십 년이라는 장기간의 실험기간을 필요로 한다. 본 연구에서는 기존의 방청법을 포함하여 최근에 개발, 사용되고 있는 강교용 방청법의 장기내구성의 단기간 평가를 위한 기초단계로서 무도장 강재의 부식내구성 평가를 위한 부식환경 촉진실험법의 활용에 대해 검토하였다. 본 실험에는 일본공업규격(JIS)에 규정되어 있는 S6-cycle 부식환경 촉진실험조건을 이용하여, 30, 60, 90, 120, 150일간의 무도장 강재의 부식 중량감소량 및 두께감소량의 경시변화를 정량적으로 평가하였다. 그리고 기존의 대기노출실험과 본 실험으로부터 구한 중량감소량을 이용하여 촉진배율을 산출하고, 대기노출실험지의 지역환경구분, 해안선으로부터 거리, 아황산가스량 및 비래(飛來)염분량과의 관계를 검토하였다. 그 결과, 촉진배율을 비래염분량으로 정식화하였으며, S6-cycle 부식촉진실험결과의 대기노출환경에의 활용 가능성을 제시하였다.

Oxytetracycline의 단기 노출이 제브라피쉬의 행동 및 내분비 반응에 미치는 영향 (Effects of the Acute Exposure Oxytetracycline on the Behavior and Endocrine Response in Adult Zebrafish)

  • 고은성;이승헌
    • 생명과학회지
    • /
    • 제25권2호
    • /
    • pp.151-157
    • /
    • 2015
  • Zebrafish는 약리학 연구에 널리 사용되는 실험 동물 중 하나이다. Oxytetracycline은 넓은 항균 범위를 가지는 항생제로써 단백질 합성을 억제하여 정균 작용을 가진 항생제이다. 본 연구의 목적은 OTC에 노출이 되었을 때 zebrafish에게서 나타나는 행동변화와 내분비계의 변화를 관찰하였다. OTC (50, 100 or 200 mg/l)에 노출된 zebrafish의 행동변화를 확인하기 위해 novel tank test와 open field test를 진행하였다. 또한 내분비계의 변화를 확인하기 위하여 whole-body cortisol의 수치를 cortisol kit를 이용하여 측정하였다. Novel tank test 결과 상층부에서 머문 시간과 부동 시간에서 OTC를 약욕하였을 때 통계적으로 유의성이 있는 증가현상이 확인되었다. 반면에, 총 이동거리, 과행동 시간, 유영 속도 그리고 상하 변위에서 OTC를 약욕하였을 때 통계적으로 유의성 있는 감소 현상이 확인되었다. Open field test 결과 부동시간에서 OTC를 약욕 하였을 때 통계적으로 유의성 있는 증가 현상이 확인 되었다. 그러나 OTC를 약욕 하였을 때 총 이동거리, 움직인 시간, 유영 속도에서 통계적으로 유의성이 있는 감소 현상이 확인 되었다. Whole-body cortisol에서는 zebrafish에게 약욕을 하였을 때 증가하는 경향이 관찰되었다. 이러한 결과를 통하여 OTC가 zebrafish에게 화학적 스트레스로 작용한 것으로 사료된다.

VISUALIZATION OF THE INTERNAL WATER DISTRIBUTION AT PEMFC USING NEUTRON IMAGING TECHNOLOGY: FEASIBILITY TEST AT HANARO

  • Kim Tae-Joo;Jung Yong-Mi;Kim Moo-Hwan;Sim Cheul-Muu;Lee Seung-Wook;Jeon Jin-Soo
    • Nuclear Engineering and Technology
    • /
    • 제38권5호
    • /
    • pp.449-454
    • /
    • 2006
  • Neutron imaging technique was used to investigate the water distribution and movement in Polymer Electrolyte Membrane Fuel Cell (PEMFC) at HANARO, KAERI. The Feasibility tests were performed in the first and second exposure rooms at the neutron radiography facility (NRF) at HANARO in order to check the ability of each exposure room, respectively. The feasibility test apparatus was composed of water and pressurized air before making up the actual test apparatus. Due to the low neutron intensity in the second exposure room, the exposure time was too long to investigate the transient phenomena of PEMFC. Although the exposure time was improved to 0.1 sec in the first exposure room, it was difficult to discriminate detail water movement at the channel due to the high noise level. Therefore, the experimental setup must be optimized according to the test conditions. Water discharge characteristics were investigated under different flow field geometries by using feasibility test apparatus and the neutron imaging technique. The water discharge characteristics of a 3-parallel serpentine are superior to those of a 1-parallel serpentine, but water at Membrane Electrode Assembly (MEA) was not removed, regardless of the flow field type.

대체용매를 이용한 금속가공유 측정방법 타당성에 대한 현장평가 (Field Validation of alternative extraction method for the determination of airborne MWFs)

  • 정지연;백남원
    • 한국산업보건학회지
    • /
    • 제19권2호
    • /
    • pp.96-101
    • /
    • 2009
  • The purpose of this study was to conduct the field validation of alternative method(ETM method) by using non-carcinogenic, and less toxic solvents than NIOSH (National Institute for Occupational Safety and Health) analytical method 5524 for measuring the airborne metalworking fluids in workplaces. We carried out the field validation test by using the exposure chamber, guaranteeing the air sampling homogeneously in a machining environment. The ETM mixed solvent presented the complete solubility of MWFs used in test field. Based on the field test data, the bias of the ETM method from reference method, NIOSH analytical method 5524, was from -7.0% to 5.1%. The overall uncertainty of the ETM nethod was 21.6%, which satisfied the NIOSH criteria for the sampling and analytical criteria.

Derivation of External Exposure Characteristics of Industrial Radiography Based on Empirical Evidence

  • Cho, Junik;Kim, Euidam;Kwon, Tae-Eun;Chung, Yoonsun
    • Journal of Radiation Protection and Research
    • /
    • 제47권2호
    • /
    • pp.93-98
    • /
    • 2022
  • Background: This study aims to derive the characteristics of each work type for industrial radiography based on empirical evidence through expert advice and a survey of radiation workers of various types of industrial radiography. Materials and Methods: According to a Korean report, work types of industrial radiography are classified into indoor tests, underground pipe tests, tests in a shielded room (radiographic testing [RT] room test), outdoor field tests, and outdoor large structure tests. For each work type, exposure geometry and radiation sources were mainly identified through the expert advice and workers' survey as reliable empirical evidence. Results and Discussion: The expert advice and survey results were consistent as the proportion of the work types were high in the order of RT room test, outdoor large structure test, underground pipe test, outdoor field test, and indoor test. The outdoor large structure test is the highest exposure risk work type in the industrial radiography. In most types of industrial radiography, radiation workers generally used 192Ir as the main source. In the results of the survey, the portion of sources was high in the order of 192Ir, X-ray generator, 60Co, and 75Se. As the exposure geometry, the antero-posterior geometry is dominant, and the rotational and isotropic geometry should be also considered with the work type. Conclusion: In this study, through expert advice and a survey, the external exposure characteristics for each work type of industrial radiography workers were derived. This information will be used in the reconstruction of organ dose for health effects assessment of Korean radiation workers.

자계 균일 공간 확보를 위한 소동물 실험용 5G급 자계 발생장치의 최적 설계 (Sptimum Design of a Uniform Magnetic Field Exposure System for a Small-Sized Animal Study)

  • 김상범;추장희;이동일;명성호
    • 한국전자파학회논문지
    • /
    • 제11권7호
    • /
    • pp.1194-1203
    • /
    • 2000
  • 1 mG부터 5 G까지 발생시킬 수 있는 소동물 실험율 60Hz 자계 발생장치를 설계하고 제작하였다. 동시에 많은 동물을 시험하기 위해서는 발생장치 내의 균일한 자계 분포 영역이 넓어야 하는데, 본 고에서는 SD-계쥐 약 50마리를 수용할수 있도록 하기 위해 소동물의 거주 공간을 장치 내부 1$\times$1$\times$1m3 크기로 하고 전체 발생장치의 크기는 1.8$\times$1.8$\times$1.8m3 입방형으로 설정하였다. 장치 내부의 자계 균일도를 검증하기 위해서 3차원 자계 계산 프로그램을 개발하였고, 이를 이용하여 거주 공간의 자계 분포가 가장 균일하게 되는 내.외곽코일의 최적 전류비 및 위치를 결정하였다. 또한 수치계산을 통한 임피던스에 근거하여 전원장치를 제작하였다. 제작된 자계 발생장치는 측정을 통하여 동물 거주 공간의 자계 최대치와 최소치의 차이가 3% 이내임을 확인할수 있었고 정밀한 소동물 자계 노출 시험용으로 사용 가능한 것으로 판단되었다.

  • PDF

휴대폰 전자파가 인체의 시각 자극 반응에 미치는 영향 (The Effects of Electromagnetic Field Emitted by Cellular Phone on Cognitive Function in Human)

  • 김재성;유창용;김수찬;오학태;육재림;김덕원
    • 한국전자파학회논문지
    • /
    • 제14권6호
    • /
    • pp.606-615
    • /
    • 2003
  • 본 연구에서는 일상생활에서 사용하는 휴대폰에서 방출되는 전자파가 인체의 시각 자극 반응에 미치는 영향을 연구하였다. 기존의 국외연구에서는 현재 국내에서 사용되고 있지 않는 아날로그 방식 또는 GSM 방식의 휴대폰을 사용한 연구였으나 본 연구에서는 현재 국내에서 사용되고 있는 CDMA 방식의 휴대폰을 사용하여 시각 자극 반응에 미치는 영향을 평가하였다. 실험은 청소년 집단(10명, 연령:14.3$\pm$1.1세)과 성인 집단(10명, 연령:24.5$\pm$3.4세)으로 구성된 20명의 지원자를 대상으로 실시하였다. 전자파 노출은 실제 휴대폰을 사용하여 이루어졌고, 실제 노출과 허위 노출의 순서에 따른 영향을 없애기 위해 blind test로 노출 순서를 교번시켜서 대등하게 하였다. 실험 결과 CDMA휴대폰에서 방출되는 전자파에 노출되었을 경우 기존의 연구(아날로그 및 GSM방식)에서 제시하는 바와 같이 청소년의 경우에는 자극 반응 속도가 노출군에서 유의하게 빨라짐을 관찰하였다.

복합열화촉진실험 및 장기현장폭로실험에 의한 RC구조물 보수공법의 보수성능평가 (Performance Evaluation of Repair Methods for RC structures by Accelerating Test in Combined Deterioration Chamber and Long-Term Field Exposure Test)

  • 권영진;김재환;한병찬;장승엽
    • 한국철도학회논문집
    • /
    • 제9권4호
    • /
    • pp.349-356
    • /
    • 2006
  • At present, the selecting system and analytic estimation criterion on repair materials and methods of the deteriorated RC structures have not yet been set up in domestic. Under these circumstances, deterioration such as shrinkage crack, corrosion of rebar has been often occurred after repair, and this finally results in too frequent repairs. In this study, three types of repair methods were experimentally investigated by the accelerating test in a combined deterioration chamber and long-term field exposure test. Three types of repair methods applied in this study belong to a group of polymer cement mortar, which is commonly used in repair works. According to the results of this study, durability of repair mortar layers and corrosion properties of recovered rebar could be investigated in short period by the accelerating test in a combined deterioration chamber, which can simulate the condition of repeated high-and-low temperature and repeated dry-and-wet environment, spraying chloride solution and emitting $CO_2$ gas. After 36 month long-term filed exposure test in the coastal area, harmful macro-cracks are observed in the polymer cement mortar layer of some repair methods. These crack are considered to result from drying shrinkage of polymer cement mortar. Also, after 36 month exposure, amount of corrosion area and weight loss of rebar are found to be different according to the types of repair methods.

이동전화 주파수에 대한 전자파 잔향실 형태의 전신 노출장치 개발 및 유효성 평가 (Development and Validation of Reverberation Chamber Type Whole Body Exposure System fer Mobile Phone Frequency)

  • 정기범;고경배;도현정;백정기;정연춘;최재훈
    • 한국전자파학회논문지
    • /
    • 제15권3호
    • /
    • pp.291-300
    • /
    • 2004
  • 이동통신 서비스의 급격한 증가로 인해, EMF(Electromagnetic field)노출의 생물학적 효과에 대한 많은 연구들이 수행되어져 왔다. 그러나 연구 수행에 있어서 필요한 무선 주파수 대역에서의 균일장 생성은 쉬운 일이 아니다. 이러한 어려움을 극복하기 위해 전신노출 시 스템에서의 전기장과 SAR(Specific Absorption Rate) 분포 측정이 발전을 해왔다. 본 논문에서는 EMC 대용 챔버로의 활용 가능성이 높은 전자파 잔향실 챔버를 이용하여 동물 실험용 전신 노출 장치를 개발하였다. 설계된 전자파 잔향실은 시뮬레이션과 측정 데이터를 이용하여 시험영역의 균일장에 대한 유효성을 검증하였다. 마우스에 대한 전신노출 실험에 있어서, 노출된 전자파에 대해 SAR을 확인하기 위해서 FDTD수치해석 방법과 측정 결과를 비교하였다. 전자파 잔향실 내부에서의 전기장 분포 특성을 해석하고, 이러한 해석 결과들을 통계적으로 처리하였다. CDMA 이동전화 주파수 대역에서(PCS & Cellular 대역) 입력 파워 변화에 따른 실험상태에서의 마우스 전신 SAR 평균값 및 국부 최대값을 제시하였다.