• 제목/요약/키워드: Field Installation

검색결과 1,198건 처리시간 0.025초

광촉매 적용 감성콘크리트 시작품 현장적용 (Field Application of Protopype LEFC Applied With Photocatalys)

  • 김병일;오상근;박현호;김수연
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.152-153
    • /
    • 2021
  • Various types of panels can be designed using acrylic rods, which are materials that allow light to pass through existing concrete. After designing using people, animals and objects, a prototype was produced by mixing ultra-high-strength concrete, and taking care not to damage the fixed acrylic rod during pouring and demolding. Yun Dong-ju's free design of a figure and a researcher were inserted into the wall inside the interior space, and then the installation was completed on-site. For installation, a metal frame was installed on the temporary wall, which is a non-structural wall, and then a relatively heavy concrete panel was fixed using a structural sealant and then applied to the field.

  • PDF

관로 이격거리에 따른 지중매설관의 거동특성 비교 (Comparison of Behaviors for Underground Flexible Pipes with Installation Gap)

  • 이대수;상현규;김경열;홍성연
    • 한국지반공학회논문집
    • /
    • 제19권5호
    • /
    • pp.79-87
    • /
    • 2003
  • 현행 지중전력선관로 건설시에 사용되는 표준공법은 관과 관사이의 거리를 l0cm 이격시켜 관로를 매설함에 따라 공정이 복잡하고, 경제적이지 못해 이에 대한 개선공법으로 관사이의 좌우이격거리를 없앤 접촉관 공법을 제안하였으며, 이 두 공법의 거동특성과 안정성을 비교$.$평가하고 지중매설관의 변형에 영향을 미치는 주요인자를 분석하기 위해 실규모 현장 실증실험을 수행하였다. 실험에 적용된 매설형태는 A-1급 도로포장아래 매설깊이 80cm, 100cm, 120cm 지점에 PE파형관이 각 공법형태에 맞게 매설되고, 외부하중으로 DB-24차량의 후륜하중 9.6ton이 매설관 상단 중앙에 정차했을 때 관이 받는 작용압력-변형률 특성을 분석하였다. 실험 결과, 지중매설관의 변형은 주로 시공과정중에 발생하는 것으로 나타났고, 특히, 모래되메움 공정 및 쇄석 포설 완료후에 변형이 가장 크게 발생하는 것으로 계측되었다. 그리고, 접촉관과 이격관 공법의 변형을 비교해 보면, 이격된 부분에 채워진 되메움재의 수동토압에 의한 저항압에 의존한 이격관 공법이 관과 관이 직접 접촉하여 관의 강성이 저항압으로 작용하는 접촉관 공법에 비해 변형이 작게 발생하는 것으로 분석되었다. 더불어 KS-C8455의 허용변형률 3.5%에 매설깊이 80cm, 100cm, 120cm에 묻힌 매설관이 공법 및 다짐방법에 관계없이 만족하는 변형률값을 보이고 있어 안전성을 확보하는 것으로 분석되었다.

Assessment of Magnetic Field Mitigation and Electrical Environmental Effects for Commercially Operating 154kV Transmission Lines with Passive Loop

  • Lee, Byeong-Yoon;Myung, Sung-Ho;Ju, Mun-No;Cho, Yeun-Gyu;Lee, Dong-Il;Lim, Yun-Seog;Kim, Sang-Beom
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.991-996
    • /
    • 2014
  • Power frequency magnetic field is still a critical problem for new construction of overhead power transmission lines in Korea because most people have been concerned about possibly carcinogenic effects of it. Although reference level of power frequency(60Hz) magnetic field has been set to 200uT in ICNIRP guidelines published in 2010, Korean government has no intention of adjusting 83.3uT specified by law in 2006 to this new reference level in consideration of people's concerns for the time being. Regardless of the current regulated magnetic field value, electric utility company has been trying to reduce magnetic field in the residential area in the vicinity of overhead power transmission lines to take into account of public concerns on the long-term effect of magnetic fields. In an effort to reduce magnetic field, engineering side has made considerable efforts to develop passive loop based, cost-effective mitigation technique of power frequency magnetic field more than ten years. In order to verify developed power frequency magnetic field mitigation technique based on passive loop, a horizontal type of passive loop was designed and installed for commercially operating 154kV overhead power transmission line for the first time in Korea. The measurement results before and after the installation of passive loop showed that magnetic field could be reduced to about 20%. The electrical environmental effects such as AN, RI and TVI were assessed before and after the installation of passive loop and these values were complied with the requirements specified by electric utility. It has been confirmed from the field test results that passive loop could be commercially and cost-effectively utilized to mitigate power frequency magnetic field.

공동주택 금속기와지붕 수뢰시스템의 자재 및 시공기법 개발 (Development of Components and Installation Techniques of Air-termination System on the Metal Roof in Apartments)

  • 이기홍
    • 조명전기설비학회논문지
    • /
    • 제25권10호
    • /
    • pp.109-115
    • /
    • 2011
  • Apartments covered with a metal roof made from galvalume steel are prevailing due to their economic and technical advantages. The metal roof, however, has disadvantages in terms of the installation of air-termination system on it because of the slip thickness of the metal roof. In this paper, the impacts of the lightning current to a metal roof were verified experimentally with a short lightning impulse current (10/350[${\mu}s$]). Also, we developed various supporters of air-termination conductor for the metal roof and verified their excellent workability and economical strength through field application test.

휴대 가능한 Lonworks 네트워크 설치 장비의 설계 (Design of portable Lonworks Network Installation Tool)

  • 이희찬;김명균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.127-129
    • /
    • 2006
  • The distributed control system is used in wide control fields. Factory automation, home network and building automation are good examples. Lonworks that Echelon company has been developing and providing since 1991 is one of popular distributed control systems. Lonwork system is support various communication media, especially it has a feature that supports communication through the power line. When Constructing Lonworks network in a construction field, the experts, who can treat Lonworks bring laptops that LNS and Lonmaker installed, install the network. However this way takes long time to construct the network and needs the experts. To resolve this problem, this paper suggests that a design of Lonworks network installation machine that is easy to use for everyone and portable. Non-experts can install Lonworks network by using this machine so they can reduce fare for installation of network and time to install.

  • PDF

실내실험과 현장실험을 통한 다양한 PVD의 연약지반개량효과 (Laboratory Test and Field Study of Soft Ground Improvement Effect by Using Various PVDs)

  • 신은철;쟌나라 나자로바
    • 한국지반신소재학회논문집
    • /
    • 제7권2호
    • /
    • pp.15-21
    • /
    • 2008
  • 인공연직배수재는 일반적인 샌드드래인에 비하여 비용 절감, 지반 교란의 최소화, 시공성 및, 시공 중에 발생될 수 있는 배수재의 변형을 최소화하는 유연성을 지니고 있다. 본 연구에서는 실내실험을 통하여 측압과 동수경사에 따른 여러형태 PVD의 통수능을 도출하였다. 시험결과는 압밀된 점토에 대한 과압력이 증가하였으며, 또한 PVD 공시체의 측압도 증가하였다. 이는 측압이 증가함에 따라 통수능이 감소됨을 나타내고 있으며, PVD 코어의 공극크기는 통수능과 비례관계에 있음을 보여준다. 현장조건을 고려하여 시뮬레이션을 통한 침하량에 대한 수치해석을 수행한 결과 현장계측한 침하량과 유사하게 나타났다.

  • PDF

압력변화에 따른 Ar/$N_2$및 Kr/$N_2$ 혼합가스의 절연파괴 특성 (Breakdown Characteristics of Ar/$N_2$ and Kr/$N_2$ Gas Mixtures with Pressure Variation)

  • 이상우;이동인;이광식;김인식;김이국;배영호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2001년도 학술대회논문집
    • /
    • pp.187-191
    • /
    • 2001
  • In this paper, the ac breakdown characteristics of Ar/$N_2$and Kr/$N_2$gas mixtures with gas pressure range of 58.8~137.3[kPa] under uniform and non-uniform fields were investigated. Summarizing the experimental results, the breakdown voltages of Ar/$N_2$ gas mixtures were decreased with decreasing the mixture ratio of pure $N_2$gas. In case of Ar(85%)/$N_2$(15%) and Ar(70%)/$N_2$(30%) gas mixtures comparing to the pure Ar gas, the breakdown voltages under uniform field were increased about 1.8 and 2.2 times, and under non-uniform field were increased about 1.1 and 1.3 times at the pressure of 101.3[kPa]. Also, in case of Kr(85%)/$N_2$(15%) and Kr(70%)/$N_2$(30%) gas mixtures comparing to the pure Kr gas, the breakdown voltages under uniform field were increased about 1.7 and 2.0 times, and under non-uniform field were increased about 1.0 and 1.2 times.

  • PDF

등각사상방법을 이용한 도체로 보강된 결합 도파 선로의 정전기장과 전위 분포 해석 (Analysis of Electrostatic Field and Potential Distributions in Conductor-Backed Coupled Coplanar Waveguide Using Conformal Mapping Method)

  • 유태훈;한기수
    • 조명전기설비학회논문지
    • /
    • 제24권6호
    • /
    • pp.35-42
    • /
    • 2010
  • 본 논문에서는 등각사상 방법(conformal mapping method)을 사용하여 도체로 보강된 결합 도파 선로(conductor-backed coupled coplanar waveguide)의 정전기장 분포와 전위 분포를 계산하는 해석적인 수식을 유도하였다. 그리고 유도한 수식을 사용하여 결합 도파 선로 구조 전체에 분포하는 정전기장과 전위분포를 계산하고 이를 분석하였다. 논문에서 사용한 방법은 반복계산 과정을 필요로 하지 않으므로 이를 사용하면 전파해석방법(full-wave analysis method)보다 전기장분포를 빠르고 간편하게 계산할 수 있다. 이 방법은 결합기, 필터, 마이크로스트립 안테나와 같은 결합선로를 사용한 마이크로파집적회로의 분석에 폭넓게 응용될 수 있다.

자계내에서 직류 차단시 아크소호 특성에 관한 연구 (A Study on the Characteristics of Arc Quenching of DC Interruption in the Magnetic Field)

  • 이동원;송현직;박원주;이광식;이동인
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제10권5호
    • /
    • pp.66-74
    • /
    • 1996
  • 본 연구는 자계내에서 직류 차단설비의 아크소호 현상을 규명하기 위하여 침대 평판 전극에 부극성 직류 고전압 인가시 아크전압 및 전류 그리고 이들 파형특성을 자계세기의 변화에 따라 연구 검토하였다. 본 연구에서 얻은 중요한 결론은 다음과 같다. 자계가 인가되지 않았을 때는 아크동특성이 나타나지 않고 아크전압의 감소와 아트전류의 증가가 순간적으로 이루어진 후, 일정하게 유지되었을 뿐만아니라 전류 파형으로부터 아크방전이 연속적으로 발생됨을 알수 있었다. 자계가 인가되면 아크동특성이 나타난후, 서서히 아크전압이 감소되고 증가되고 아크전류는 감소되었다. 그리고 전류파형으로부터 아크방전은 단속적으로 됨에 따라 전류영점이 나타남을 알 수 있었고, 전류영점이 나타나는 주기와 아크방전의 단속 주기가 일치하였으며 자계가 증가될수록 주기도 증가되었다.

  • PDF

유한장 직선도체에 의한 자계의 계산 및 감소대책 (Calculation and Mitigation of Magnetic Field Produced by Straight Line-Conductor with Finite Length)

  • 강대하
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.57-67
    • /
    • 2011
  • Purpose of this study is to find the mitigation method of magnetic field by finite length multi-conductors such as indoor distribution lines and to be applicable to design of the distribution lines. For this purpose, exact formula about the components $B_x$, $B_y$, $B_z$ of magnetic field need in case of straight line-conductor with finite length forward any direction. In this study simple formula of the components were deduced and by using these formula magnetic fields for various models of line-configurations were calculated. And also a calculation method of induced currents in conductive shield was presented and using this method, programing of calculation is relatively easy and calculation time is short. The magnetic field after cancellation by these induced currents was calculated. All of calculations were performed by Matlab 7.0 programs. Through the calculation results it could be obtained followings for the mitigation of magnetic fields. The separation between conductors ought to be smaller than smaller as possible. In case of 3-phase, delta configuration is more effective than flat configuration. In case of 3-phase, unbalanced currents ought to be reduced as possible.. In case of more than two circuits of 3-phase, adequate locations of each phase-conductor such as rotating configuration of 3-phase conductors are more effective. The magnetic shielding effect of the conductive shielding sheet is very high.