• Title/Summary/Keyword: Field Installation

Search Result 1,198, Processing Time 0.021 seconds

Performance Evaluation of Low Frequency Magnetic Field Shielding by Eddy-Current (와전류에 의한 저주파 자기장 차폐 성능 평가)

  • Choi, Hak-Yun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.124-128
    • /
    • 2010
  • In this paper, the shielding effectiveness of aluminum shielded room with using eddy-current is calculated and measured after fabricated. The size and thickness of shielded room are decided as $2.4{\times}2.4{\times}2.4[m^3]$ and 12[mm] after AC shielding characteristics by eddy-current of conductive materials is analyzed. To verify the shielding effectiveness, a rectangular helmholtz coil is fabricated to generate magnetic field of 1.37[${\mu}T$] and measured magnetic field inside shielding room for 0.01~10[Hz]. According to calculations and measurements, AC Shielding effectiveness by eddy-current in aluminum is very small for 0.01~2[Hz] and 5 times to 11 times for 5~10[Hz].

Analysis on Parameter Detuning of Induction Motor Drives in Field Weakening Region (약계자영역에서 유도전동기 고정자자속기준제어의 파라미터 비동조 영향 분석)

  • Shin, Myoung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.118-123
    • /
    • 2010
  • The selection of flux level in the maximum torque control of stator flux-oriented induction motor drives in the field weakening region is dependent on stator resistance and inductances. This paper presents parameter detuning effects of stator flux-oriented control drives in the field weakening region. The detuning effects of stator resistance and rotor leakage inductance are analyzed. The decrease of torque and the flux control lost by the detuning of inductance are shown in the simulation results.

A Study on the Dual PWM Digital Excitation System of Regeneration Type (회생형 이중화 PWM 방식의 디지털 여자시스템에 관한 연구)

  • Ryu, Ho-Seon;Lee, Joo-Hyun;Lim, Ick-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.79-84
    • /
    • 2010
  • This paper discusses the control of generator field using dual IGBT PWM regeneration method to target brushless synchronous generator. If one of PWM bridges happens to fault, it transfers automatically and can be in charge of full load. Also it has an advantage of the operation which UPS connected in parallel with PWM bridge can supply power to excitation system in condition of main power loss. This PWM system supplies field current to generator in one quadrature operation, regenerates field coil energy to main power supplier in four quadrature operation. We designed, manufactured and applied the first trial product at J-power plant.

Development of a New-Concept Lightning Warning System (신개념 뇌경보 시스템 개발)

  • Choi, Su-Yeon;Park, Chan-Yong;Kil, Gyung-Suk;Ahn, Chang-Hwan;Lee, Young-Kun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.297-300
    • /
    • 2008
  • This paper described a New-Concept lightning warning system (LWS) which can measure electric field intensity on the ground level by an electric field mill (EFM) and calculate the lighting location by radiated electro-magnetic waveform. The EFM measures electric field up to 20[kV/m] with the sensitivity of 0.15[V/kV/m] and frequency bandwidth of the loop antenna was ranges from 5.2[kHz] to 1.71[MHz]. The LWS provides data on the movements of thunderclouds and the possibility of lightning return stroke.

  • PDF

Prebreakdown Field Emission of Micrometric Vacuum Gaps under DC Voltage (직류 전압에 의한 미소 진공갭의 전구방전 전계방출)

  • 김정달;이세훈
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.2
    • /
    • pp.56-63
    • /
    • 1997
  • 진공에서의 파괴는 파괴전구현상으로부터 개시되고, 파괴전구현장중에서 가장 중요한 과정은 Metallic Field Electron Emission과 Micro Discharge이다. 진공내에서 평등전계 갭의 전기적 파괴특성 중 전극에 흐르는 방전전구전류는 전계에 의존하고 Fowler Nordheim 식으로 나타낼 수 있다. 이 논문은 압력 760, 1.2$\times$10-3, 1.2$\times$10-5[torr]과 스테인레스 전극을 미소갭 20, 50, 75, 100[$\mu\textrm{m}$]으로 구성하여 방전전구전류에 대해서 실험적으로 연구했다. 전극갭과 압력변화에 따라 얻어진 I-V 특성곡선을 Fowler Nordheim의 전계방출 이론에 입각해서 분석한 결과, 진공중 미소갭의 전기적 파괴기구는 Metallic Field Electron Emission (M-FEE)에만 의존되었다.

  • PDF

REDUCTION CHARACTERISTICS Of ELECTROMAGNETIC PENETRATION THROUGH NARROW SLOTS BY RESISTIVE SHEETS LOADING (장하 저항시트의 구조변화에 따른 슬릿 침투 전자파 저감특성)

  • Park, Eun-Jung;Ju, Chang-Hyun;Kim, Ki-Chai;Kim, Lee-Kook
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.107-110
    • /
    • 2005
  • This paper presents the reduction methods of penetrated electromagnetic fields through a narrow slot aperture in a planar conducting screen of infinite extent. When a plane wave is excited to the narrow slot, the aperture electric field is controlled by the resistive sheets loading on the slot. The magnitude of the penetrated electromagnetic fields through a narrow slot is controlled by electric field distributions on the slot aperture. The results show that the magnitude of the penetrated electromagnetic field can be effectively reduced by the resistive sheets on the slot aperture.

  • PDF

Introduction of the field - test evaluation system in KEPCO (배전 실증시험장 시스템 현황 소개)

  • Kim, Dong-Myung;Choi, Sun-Kyu;Jang, Sang-Ok;Oh, Jae-Hyoung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.81-85
    • /
    • 2004
  • This paper describes the testing facility to demonstrate the performance of the distribution class circuit breakers and switchgears and the testing methods. The field-test evaluation system consists of two parts. One is the distribution system for simulation of the condition on interruption mode of switches which are installed in the system and tested by the AFG(Artificial Fault Generator) and the thunderbolt generator just like in the real field. The other is a laboratory for confirmation or the important characteristics regarding to the insulation, gas, environment durability of equipment. For the fatal failure mode, a FMEA(Failure Modes and Effects Analysis) technique which is a kind of a structural analysis to consider a counter-plan was emploved.

  • PDF

Aging Characteristics of Polymer Lighting Arrester by Multi-Stress Accelerated Aging Test (복합가속열화시험에 의한 폴리머 피뢰기의 경년특성)

  • Song, Hyun-Seok;Lee, Jae-Bong;Jang, Sang-Ok;Han, Yong-Huei;Oh, Jae-Hyoung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.86-89
    • /
    • 2004
  • Recently polymer arresters are being used widely but we don't have appropriate long term characteristics test methods. Therefore we need to develop special test facility to evaluate long term reliability of polymer arresters. It's polymeric housing can be degraded by environmental stress and the interface between housing and inner module can be affected by moisture absorption. This moisture absorption can cause leakage current and tracking in the interface. We developed multi stress accelerated ageing test facility to simulate field conditions including UV, temperature, humidity, voltage, salt fog and rain. In addition, we carried out field exposure test at the outdoor test yard and characteristics analysis of field operated specimens to evaluate accelerating factor of this accelerated aging test.

  • PDF

Collision Avoidance Path Planning for Multi-Mobile Robot System : Fuzzy and Potential Field Method Employed (멀티 모바일 로봇 시스템의 충돌회피 경로 계획 : 퍼지 및 포텐셜 필드 방법 적용)

  • Ahn, Chang-Hwan;Kim, Dong-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.163-173
    • /
    • 2010
  • In multi-mobile robot environment, path planning and collision avoidance are important issue to perform a given task collaboratively and cooperatively. The proposed approach is based on a potential field method and fuzzy logic system. For a global path planner, potential field method is employed to select proper path of a corresponding robot and fuzzy logic system is utilized to avoid collisions with static or dynamic obstacles around the robot. This process is continued until the corresponding target of each robot is reached. To test this method, several simulation-based experimental results are given. The results show that the path planning and collision avoidance strategies are effective and useful for multi-mobile robot systems.

REDUCTION CHARACTERISTICS OF ELECTROMAGNETIC PENETRATION THROUGH MARROW SLOTS BY RESISTIVE SHEETS LOADING (장하 저항시트의 크기변화에 따른 슬릿 침투 전자파 저감특성)

  • Park, Eun-Jung;Cho, Jun-Ho;Kim, Ki-Chai
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.281-283
    • /
    • 2006
  • This paper presents the reduction methods of penetrated electromagnetic fields through a narrow slot aperture in a planar conducting screen of infinite extent. When a plane wave is excited to the narrow slot, the aperture electric field is controlled by the resistive sheets loading on the slot. The magnitude of the penetrated electromagnetic fields through a narrow slot is controlled by electric field distributions on the slot aperture. The results show that the magnitude of the penetrated electromagnetic field can be effectively reduced by the resistive sheets on the slot aperture.

  • PDF