• Title/Summary/Keyword: Field Installation

Search Result 1,198, Processing Time 0.02 seconds

Evaluation of Field Calibration Test on Rail for Train Wheel Force Measurement

  • Sim, Hyoung-Bo;Yeo, Inho
    • International Journal of Railway
    • /
    • v.8 no.1
    • /
    • pp.1-4
    • /
    • 2015
  • An accurate measurement of the train-track interaction forces is important for track performance evaluation. In the field calibration test as a wheel load measurement process, the calibration system creates a different boundary condition in comparison with that in the train wheel passage. This study aims to evaluate a reliability of the field calibration test in the process of wheel load measurement. Finite element models were developed to compare the deformed shapes, bending moment and shear force profiles on the rail section. The analysis results revealed that the deformed shapes and their associated bending moment profiles on the rail are significantly different in two numerical simulations of the calibration test and the train wheel load passage. However, the shear stress profile on the rail section of the strain gauge installation in the field was almost identical, which may imply that the current calibration test is sufficiently reliable.

A Study on the Effect of Magnetic Field in Electrostatic Precipitator for Improving Precipitation Efficiency of Particulate Matter (미세먼지의 집진효율 향상을 위한 전기집진기의 자계인가특성에 대한 연구)

  • Park, Jae-Youn;Han, Sang-Bo;Park, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.122-129
    • /
    • 2008
  • This paper gives the experimental results for the effective precipitation of particulated matter(PM) below 1[${\mu}m$] of diameter using the electrostatic precipitator, which is designed by ourselves. In order to improve the precipitation efficiency, the vertical and parallel magnetic field to the electric field is applied simultaneously by arranging ferrite magnets. When the parallel magnetic field is applied, the precipitation efficiency does not improve in comparison with non-magnets. However, when the vertical magnetic field is applied, it is improved about 5[%] more than the case of non-magnetized ferrite plate used. In addition, when the magnets are installed at the center of ground plate electrodes, the precipitation efficiency is ranged from 17 to 32[%] under the applied voltage of 5[kV]. It is similar to the case of the magnet arrangement at the front part of ground electrode. Also, the precipitation efficiency is more improved by arranging magnets as the inside part and zigzag on the electrodes. Especially, large particles of 0.7 and 1[${\mu}m$] is more easily captured by electrostatic precipitator. Consequently, it is convinced that the vertical magnetic field is more desirable than parallel magnetic field on the electric field for the effective treatment of particulated matter.

The Investigation and Analysis of Field Condition on Flood Protection Equipment of Transformer Vault in Flood Area (침수지역에서 수·변전설비 침수방지시설에 관한 현장실태 조사 및분석)

  • Kim Gi-Hyun;Kim Chong-Min;Kim Sun-Gu;Hwang Kwang-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.4
    • /
    • pp.85-90
    • /
    • 2005
  • Inundation of Transformer Vault breaks out every summer season in low-tying downtown and low-tying shore by localized heavy rain, typhoon and tidal wave. In case inundation of Transformer Vault, it occurs a great economic loss owing to recovery time and events of electric shock occur by inundation electrical facility. So we need installation plan of Transformer Vault in common flood area for preventing from economic loss and equipment events. Therefore we research distribution of 22.9[kV] Transformer Vault in common flood of the country and analyze field condition about flood protection plan. And we analyze regulation or law relating to the flood protection counterplan of US, England, Australia. This paper will be used to present a reform proposal of electrical related law about flood protection of existing Transformer Vault. Also we present considering facts at the time Transformer Vault installation in common flood area.

INSTALLATION PARAMETERS EFFECTING ON THE WIND PROOF OF A COASTAL FOREST (해안림의 방풍 효과에 영향을 미치는 설치 파라미터 분석)

  • Shin, J.H.;Chang, S.M.;Park, K.H.;Youn, H.J.
    • Journal of computational fluids engineering
    • /
    • v.20 no.2
    • /
    • pp.52-60
    • /
    • 2015
  • The objective of this research lies in the effect of installation parameters influencing on the wind proof performance of the coastal forest for damage prevention. The dissipation ratio of incident wind power is developed as an assessment index to make a lumped parameter study possible. From the real field data of East, West, and South Sea bounded on the Korean peninsula, single and double storied forests were modeled in three-dimensional shape with computer aided design, and so was done the artificial structures such as wind break, sand accumulating fence, and sand dune, etc With a commercial code ANSYS-CFX, the computational result from the comparison of dissipation ratio between single and double storied forest shows the effect of composition, and also the installation effect is investigated for artificial structures with optimal dimension of distance.

A Novel Development of Distributed Intelligent Control Module Based on the LonWorks Fieldbus for Air Handling Units in the Healing, Ventilating and Air Conditioning (LonWork fieldbus 기반을 가진 HVAC 공기조화기용 고성능 지능형제어모듈 개발)

  • 홍원표
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.115-121
    • /
    • 2004
  • In this paper, a new distributed intelligent control module based on LonWoks fieldbus for air handling unit(AHU) of heating, ventilating and air-conditioning(HVAC) is proposed to replace with a conventional direct digital control(DDC) system with 32 bit microprocessor. The proposed control architecture has a excellent features such as highly compact and flexible function design, a low priced smart front-end and reliable performance with various functions. This also addresses issues in control network configuration, logical design of field devices by S/W tool, Internet networking and electronic element installation. Experimental results for showing the system performance are also included in this paper.

Commercialization of Integrated DCU for the Platform Screen Door (승강장 스크린도어를 위한 통합형 제어기의 상품화)

  • Woo, Chun-Hee;Kim, Jin-Sik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.3
    • /
    • pp.110-113
    • /
    • 2011
  • Platform Screen Door, PSD, is a device that seeks to prevent accidents with regards to falling off the platform and getting trapped between the trains, achieve improvements on the cleanliness of the air, address the accessibility issue of the disabled and the elderly and provide fresher environment on the platform in general. This is achieved by preventing health hazards and accidents from occurring through installation of fixed and moving doors between rail, tram and subway platforms and the railway. Domestic firms have achieved domestic production to a large degree in various Control Units including the Overall Control Unit and RF devices through investments in technology. Despite this, full domestic production of the core of the PSD system, Door Control Unit, DCU, is not yet achieved, having to install PSDs in a relatively short period of time. Currently, controllers with DC motors are developed for installation or one is faced with having to import foreign produced controllers. In this research, the control unit prototype using the BLDC motor was domestically produced. The performance of the control unit was rigorously tested through installation on Eun-Ha Rail on Wol-Mi Island.

Parks' Landscape Lighting Plan around Waterfront for Improving city Beautification at Night -Focused on Han Kang (river)'s Park in Seoul- (대도시 야간경관향상을 위한 수변공간 주변 공원의 경관조명개선에 관한 연구 -서울시 한강시민공원을 중심으로-)

  • 최윤석;김정태
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.26-37
    • /
    • 2002
  • The Parks'landscape lighting at night influences people's visual comfort, safety and so on. So, this study aims to suggest new lighting plan in Han Kang(river) Parks for improving the city beautification in Seoul. Therefore, field survey was performed in two parks. And The lighting fixtures ware investigated, and horizontal illuminations were measured by Topcon-IM5 to compare with the Korea Standard Some findings and problems were discussed. As a result, to improve the lighting quantity and duality of the concept, light source lighting fixtures and installation were suggested, and the scenes of suggested lighting plan ware indicated by computer graphics.

Elasticity and Viscosity Control of an Ultrasonic Motor by a Phase Difference Control (초음파 모터의 위상차 조절에 의한 점탄성 제어)

  • 우수용;이권현;오금곤;정헌상;김영동
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.5
    • /
    • pp.86-92
    • /
    • 1997
  • An ultrasonic motor(USM) has good characteristics such as compact size, silent motion, high speed responce, low speed and high torque. The USM is driven by 2-phase AC electricity. The control parameters of USM are voltage, phase, and frequency of input powers, etc. In this paper, the fine elasticity and viscosity control with no force feedback can be implemented by a phase difference parameter. Experiment results show the change of torque with regard to elasticity and viscosity. Therefore the USM can be used as a micro-actuator in the automation field of the installation.

  • PDF

A Investigation on the Actual Condition of PV Maintenance on Residental Buildings

  • Lee, Eung-Jik
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.53-58
    • /
    • 2014
  • Residental photovoltaic power system achieved remarkable results in distribution and activation through 'One Million Green Homes Program' led by the government. However, system maintenance and management after installation are relative unsatisfactory. Thus, problems, such as malfunctioning, decrease in efficiency, breakage, etc, are occurring in succession which means that expensive facilities are not used effectively. This study attempted to propose a more preferred alternative to the photovoltaic power system currently applied and installed to the housing by investigating and analyzing the said system, identifying management practices, and deriving problems. For this study, 48 houses equipped with photovoltaic systems in J City were chosen and they were analyzed after preliminary research and field investigation. The results revealed that most of the surveyed systems in J City are still in fairly good conditions. But the instruction and information regarding the appropriate operational management of those surveyed systems have not been delivered to the owner. Therefore, promotion education and related manual deployment should be done by the contractor. In terms of installation, inadequate system location and some warranty services are required to be improved, which are usually caused by a lack of careful planning and construction. In addition, the follow-up management needs to be provided about five years later after installation considering system deterioration.

Evaluation of Numerical Models for Analysing an Industrial Centrifugal Blower (산업용 원심블로어 수치해석을 위한 수치모델 평가)

  • Lee, Jongsung;Jang, Choonman
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.6
    • /
    • pp.688-695
    • /
    • 2012
  • The present study represents the effects of boundary condition on the performance of a centrifugal blower at the interference plane between rotational and stationary domains using three dimensional compressible Navier-Stocks equations. Two boundary conditions, frozen-rotor and stage, are compared to analyze the blower performance. Installation angle between the cutoff of a volute casing and a impeller blade is also introduced to evaluate the blower performance and to understand the internal flow inside the blower. Throughout numerical simulation, it is found that the frozen rotor interface method at the interference plane represents well the variations of flow field inside the blower compared to stage interface method. However, pressure has maximum two percent error according to the installation angles while pressure is almost constant for the stage interface method. And stage interface method can relatively well predict the blower performance. Detailed internal flows of the centrifugal blower are compared and analyzed by numerical simulation.