• Title/Summary/Keyword: Field Installation

Search Result 1,198, Processing Time 0.02 seconds

The Characteristics Change of Fluorescent Lamp According to Tube Shape (관의 형태에 따른 형광램프의 특성 변화)

  • 노재엽;이진우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.3
    • /
    • pp.1-5
    • /
    • 2000
  • This paper described about variance of optical and electrical characteristics on a fluorescent lamp according to tube shape by measuring electric field of positive column, temperature and luminance of tube w- all. Electric field calculation of several amps shows that the characteristics was not changed in positive column, though cathode fall length, and the values of temperature and luminance of tube wall, changes mush in cathode region.

  • PDF

A Study on Electric Conduction Characteristic in the Glass Transition Point of electric Power Equipments Cross - Linked Polyethylene (전력설비용 가교 Polyethlene의 Glass 전이점에서의 전기전도 특성에 관한 연구)

  • 김강원;서장수;김병인;국상훈
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1991.10a
    • /
    • pp.64-68
    • /
    • 1991
  • It happened that there was a sudden peak with the capacity of change, when I measured the capacity of change, cubical expansion and Thermally Stimulated Current on the Cross - Linked Polythylene. Crystal melting began at 375 K and changed into formaless shapeless at 380 K. The conduct of a particle on the surfase of dipole, electron trap was founded to be ion conduction nature under the low electronic field, wherase, the electron nature under the high electronic field. Consequentity, under the semi-conduction layer electronic a particle was injected to inter-fase and accumulated for a time and appeared to be TSC.

  • PDF

A Study on Reliability Analysis for Reliability Testing & Field Degradation Data of LED Lighting (LED조명기기의 필드 열화데이터에 대한 신뢰성 분석에 관한 연구)

  • Yang, Seong-Yong;Yi, Chin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.12
    • /
    • pp.54-59
    • /
    • 2011
  • LED lightings typically do not fail catastrophically during use. However, over time the light output will gradually depreciate. Even if there are same LED lighting, they are so different at all. because of dissimilar the use and environment of each LED lighting. In this paper, we make a description of reliability analysis procedures for the degradation data using collected field data. Reliability analysis procedures are consisted of estimating degradation models and failure time, verification of distribution and parameters of the distribution, and reliability measures estimation. At some point in time, the light emitted from an LED lightings depreciates to a level where it is no longer considered adequate for a specific application.

A Study on the Terrestrial DTV Channel Model (지상파 DTV 채널 모델에 관한 연구)

  • Lee, Seung-Youn;Na, Chae-Dong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.57-65
    • /
    • 2010
  • In this paper we proposed channel models for terrestrial ATSC (Advanced Television Systems Committee) DTV (Digital Television) system in South Korea. For the purpose of this model, we research on propagation model involved in terrestrial DTV system and analyze out field test data of terrestrial DTV broadcasting carried out in korean Broadcasting System. Using the measured values of received field strength, newly proposed Path-loss models have more correctly than that of conventional Path-loss models. This models can be utilized usefully for the efficient ATSC DTV system implementation requiring accurate link-budget calculation

Study on the High Efficiency of Anode Phosphor Electrode for Filed Emission Lamp (I) Metal Layer (전계방출광원용 고효율 에노드 형광막 특성 연구(I) - 금속막)

  • Lee, Sun-Hee;Kim, Kwang-Bok;Kim, Yong-Won;You, Yong-Chan
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.7-10
    • /
    • 2007
  • The electron charging and degradation of anode phosphor layers are showed major problems in high electric field with anode electrode of field emission devices. An Al metal layer on the phosphor layer may get rid of these problems. This Al metal layer are formed with the roughness of phosphor surface layer without interlayer and cannot be given rise to enhance the luminance efficiency. In order to enhance the brightness, an anode layer need to be flated between phosphor layer and Al metal layer in anode electrode. After optimizing the anode phosphor layer, an anode layer with Al metal and inter layer increased the brightness and luminescence efficiency 1.5 times more than only phosphor layer in anode.

  • PDF

The Precision Laser Range Finder Using Laser Diode for Industrial Applications (반도체 레이저를 이용한 산업용 정밀 거리 측정 시스템)

  • Woo, Sung-Hun;Park, Jung-Hwan;Kim, Young-Min;Park, Dong-Hong;Park, Won-Zoo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.231-234
    • /
    • 2007
  • A measurement technique in an industry site is basis technique which is bringing a ripple effect on an increasing productivity. Recently, a measurement request is increasing in the industry field as well as the variety field such as leisure, research. Thus, it is in point of time to secure an internal technique about measurement using a laser. In this paper, we prepare to develop the industrial precision laser distance measure device that is available measuring in several hundred meters[m]. In other words, we are planning to measure a wide distance using a laser diode that has long life and is compact, inexpensive. Through this research, we'll secure the pulse laser control technique, a signal processing, technique for distance calculation about a laser distance measurement system. And hereafter, we'll plan to commercialize a laser distance device using this research.

  • PDF

Efficiency and EMF Safety Analysis of Wireless Power Transfer System Using Standard Human Model (표준화된 인체모델을 이용한 공진형 무선전력전송 시스템의 효율 변화 및 인체 안전성 분석)

  • Shin, Hansu;Byun, Jin-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.11
    • /
    • pp.96-103
    • /
    • 2013
  • In this paper, resonant wireless power transfer systems are designed with double loop resonant coils for the resonant frequency of 150kHz. The transfer efficiency characteristics is analyzed according to the coil size, and the distance and misalignment between the coils. Then the change in efficiency is investigated when a human model is located between the resonant coils using the homogeneous human phantom of IEC-62311 standard. Also, in order to assess the safety of the wireless power transfer system, the induced current density inside the human model is calculated when it is exposed to the magnetic field of a plane wave and resonant coil. Then, the results are compared with the exposure limits in the EMF (electromagnetic field) safety guidelines.

The Measurement and Analysis The Electromagnetic Wave by Discharge in Air for Insulation Diagnosis (절연진단을 위한 기중방전에서의 방사전자파 측정과 분석)

  • 이상훈;이현동;이춘하;윤영대;김기채;이광식;이동인
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.141-144
    • /
    • 1999
  • This paper offer fundamental ones about insulation diagnosis with electromagnetic wave, when discharges occurred. To simulate Partial-Discharge(PD), It is used needle-plane electrode in air. As the voltages applied, measure the electromagnetic wave with monopole antenna and analysis its fundamental characteristics, then, acquired data were operated. The results presented as the form of graph, and the magnitude of charge when occurred PD simultaneously. In conclusion, when the magnitude of charge over 100[pC], the electric field strength changed, and then the magnitude of charge and the electric field strength increased samely.

  • PDF

Reporting on the High Efficiency of Anode Phosphor Electrode for Filed Emission Lamp - Metal Layer (전계방출광원용 아노드 난반사 연구)

  • Yun, Han-Na;Kim, Yun-Il;Kim, Dae-Jun;Kim, Kwang-Bok
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.29-32
    • /
    • 2008
  • The electron charging and degradation of anode phosphor layers are showed major problems in high electric field with anode electrode of field emission devices. An AI metal layer on the phosphor layer may get rid of these problems. This Hetero-metal-oxide phosphor layer are formed with the roughness of phosphor surface layer without interlayer and cannot be given rise to enhance the luminance efficiency. In order to enhance the brightness, an anode layer need to be flated between phosphor layer and AI metal layer in anode electrode. After optimizing the anode phosphor layer, an anode layer with AI metal and inter layer increased the brightness and luminescence efficiency 1.2 times more than only phosphor laver in anode.

  • PDF

The dual emitter structure for field emission light source (전계방출광원용 듀얼 에미터 특성 연구)

  • Kim, Kwang-Bok;Lee, Sun-Hee;Park, Ho-Seop;Yang, Dong-Wook;Kim, Dae-Jun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.151-154
    • /
    • 2008
  • The field emission lamps have the advantages to their cold cathode-characteristic and the eco-friendly, We realized that the dual emitter system showed very simple structure which gate and cathode electrodes are formed on the same glass surface. In this paper, we reported the properties of dual emitters depended on variation of gate width and spacing for optimum panel structure. In combination of dual emitter structure and bi-polar driving, electron beam spreads more than normal gate structure or diode structure, and emission uniformity increased in dual emitter structure at 5"-diagonal.

  • PDF